Document 50w1Og2EbgLZMRmpdGpn6D8o0

Ohio Bureau of Workers' Compensation Division of Safety & Hygiene One Government Center, Suite 1173 Jackson & Erie Streets Toledo, Ohio 43604 Plwnc (419)2*5-2900 To* Fi9K 1-900-629-6769 August 7, 199 1 August 6, 1991 Judy Spencer Legal Department Industrial Commission of Ohio 30 W. Spring Street, 9th Floor Columbus, Ohio 43266-0581 RE: OD 41515-22 Robert Keys GMC Central Foundry Defiance, Ohio Assignment #91-295 Dear Ms. Spencer: On June 7, 1991, Debra Pierson, Workers' Compensation Representative at General Motor's Central Foundry, Defiance was contacted by phone. The enclosed letter was received July 6, 1991. WORK HISTORY 1964 - 1985 GMC Central Foundry - Core Room - Laborer Maintenance Dust Control 1957 - 1964 Defiance Belts Products - Milk Processing Production Line 1952 - 1957 Bricker Electric Plating - Parts Washing Laborer MEDICAL HISTORY Dr. Nils V. Gomez, M.D. notes on January 28, 1989, "Both lung fields are clear except for incidental finding of mild linear fibrosis in the right lung base." On June 14, 1989, Dr. Atwell diagnosed the claimant as having pneumoconiosis from exposures at the Central Foundry. Dr. Atwell's opinion of the probable cause of pneumoconiosis is exposure to mixed dust and/or silica dust. Asbestosis .and silicosis are examples of pneumoconiosis with fibrosis. EXPOSURE POTENTIALS This section focuses on the work history at the Central Foundry since the diagnosis identifies this workplace. Numerous occupational disease investigations at General Motor's Central Foundry (GMCF) at Defiance have established the presence of airborne crystalline silica (quartz) and asbestos. The specific claim numbers which identify the airborne exposures can be provided if desired. General Motors Central Foundry OD 41515-22 Robert Keys Page 2 The claimant's work at General Motor's Central Foundry included cleaning of the foundry dust collection systems. Dust falling on machinery was blown off by the claimant. Airborne quartz exposures in the core room are possible. General Motor's Central Foundry had a plantwide asbestos removal program started November 16, 1976. Asbestos was used in hot blast ducts, on pipes and fittings. Any personal heat protection clothing contained asbestos. CONCLUSION The claimant's exposures to unknown concentrations and durations of airborne quartz and asbestos are reasonable. Sampling results for silica and asbestos (for the claimant's work site and job description) were requested, but not provided by GMC. No results characterizing exposures for the claimant's job description were in the Division files. Sincerely, Richard Wilder Industrial Hygienist RW/dr Enclosure: Letter from General Motors Central Foundry References: 1. Dorlands Illustrated Medical Dictionary 26th Ed., W.B. Sanders 1981. 2. Silica, Encyclopedia of Occupational Health & Safety. International Labour Org., Geneva, 1983. Cwt Tin *7 PM-- Gansral Motors Corporation 0thanes Plant Stato Rout* 2t> East Dsfcanes. Ohio OS12-QQ7Q July 3, 1991 Richard Wilder 2575 108th St. Toledo, Ohio 43611 Re: Robert Keys Claim OD 41515-22 Dear Mr. Wilders Per your request, this letter is to verify that Mr. Keys did work on dust collector clean up, which is a wet dust process. I have not yet determined how long he performed this particular job. If you have any further questions please do not hesitate to contact roe at 419-784-7436. Sincerely, k4w< Debra Pierson Workers * Compensation cc: Bugbee & Conkle LmGmn Uf SAMTV MiTS SAVt UV*S y RECORDS CERTIFICATION I, the undersigned, an employee of the Bureau of Workers' Compensation, do hereby certify that the microfilm images on this reel of microfilm or microfiche are complete and accurate reproductions of the original records of the +> // as accumulated during the regular course of business, and that it is the established procedure of this department to microfilm its records for permanent file and to dispose of the original records after microfilm reproductions have been made. SUPERVISOR. Mtoofikning Unit Date t ,00 Name (Camera operator) A Date _______Zf- V --------------------------------------------------------------------- 9-2S-9Z WC-5012 (7/91) <0 r I.