Document 50w1Og2EbgLZMRmpdGpn6D8o0
Ohio Bureau of
Workers' Compensation
Division of Safety & Hygiene One Government Center, Suite 1173 Jackson & Erie Streets Toledo, Ohio 43604
Plwnc (419)2*5-2900 To* Fi9K 1-900-629-6769
August 7, 199 1 August 6, 1991
Judy Spencer Legal Department Industrial Commission of Ohio 30 W. Spring Street, 9th Floor Columbus, Ohio 43266-0581
RE: OD 41515-22 Robert Keys GMC Central Foundry Defiance, Ohio Assignment #91-295
Dear Ms. Spencer:
On June 7, 1991, Debra Pierson, Workers' Compensation Representative at General Motor's Central Foundry, Defiance was contacted by phone. The enclosed letter was received July 6, 1991.
WORK HISTORY
1964 - 1985 GMC Central Foundry - Core Room - Laborer Maintenance Dust Control
1957 - 1964 Defiance Belts Products - Milk Processing Production Line
1952 - 1957 Bricker Electric Plating - Parts Washing Laborer
MEDICAL HISTORY
Dr. Nils V. Gomez, M.D. notes on January 28, 1989, "Both
lung fields are clear except for incidental finding of mild
linear fibrosis in the right lung base." On June 14, 1989, Dr.
Atwell diagnosed the claimant as having pneumoconiosis from
exposures at the Central Foundry. Dr. Atwell's opinion of the
probable cause of pneumoconiosis is exposure to mixed dust and/or
silica dust.
Asbestosis .and silicosis are examples of
pneumoconiosis with fibrosis.
EXPOSURE POTENTIALS
This section focuses on the work history at the Central Foundry since the diagnosis identifies this workplace. Numerous occupational disease investigations at General Motor's Central Foundry (GMCF) at Defiance have established the presence of airborne crystalline silica (quartz) and asbestos. The specific claim numbers which identify the airborne exposures can be
provided if desired.
General Motors Central Foundry OD 41515-22 Robert Keys
Page 2
The claimant's work at General Motor's Central Foundry included cleaning of the foundry dust collection systems. Dust falling on machinery was blown off by the claimant. Airborne quartz exposures in the core room are possible.
General Motor's Central Foundry had a plantwide asbestos removal program started November 16, 1976. Asbestos was used in hot blast ducts, on pipes and fittings. Any personal heat protection clothing contained asbestos.
CONCLUSION
The claimant's exposures to unknown concentrations and durations of airborne quartz and asbestos are reasonable.
Sampling results for silica and asbestos (for the claimant's work site and job description) were requested, but not provided by GMC. No results characterizing exposures for the claimant's job description were in the Division files.
Sincerely,
Richard Wilder Industrial Hygienist
RW/dr Enclosure:
Letter from General Motors Central Foundry
References:
1. Dorlands Illustrated Medical Dictionary 26th Ed., W.B. Sanders 1981.
2. Silica, Encyclopedia of Occupational Health & Safety. International Labour Org., Geneva, 1983.
Cwt Tin *7 PM-- Gansral Motors Corporation 0thanes Plant Stato Rout* 2t> East Dsfcanes. Ohio OS12-QQ7Q
July 3, 1991
Richard Wilder 2575 108th St. Toledo, Ohio 43611
Re: Robert Keys Claim OD 41515-22
Dear Mr. Wilders
Per your request, this letter is to verify that Mr. Keys did work on dust collector clean up, which is a wet dust process. I have not yet determined how long he performed this particular job.
If you have any further questions please do not hesitate to contact roe at 419-784-7436.
Sincerely, k4w<
Debra Pierson Workers * Compensation
cc: Bugbee & Conkle
LmGmn Uf SAMTV MiTS SAVt UV*S
y
RECORDS CERTIFICATION
I, the undersigned, an employee of the Bureau of Workers' Compensation, do hereby certify
that the microfilm images on this reel of microfilm or microfiche are complete and accurate
reproductions of the original records of the
+> //
as accumulated during the
regular course of business, and that it is the established procedure of this department
to microfilm its records for permanent file and to dispose of the original records after microfilm
reproductions have been made.
SUPERVISOR. Mtoofikning Unit
Date
t ,00
Name (Camera operator)
A
Date
_______Zf-
V ---------------------------------------------------------------------
9-2S-9Z
WC-5012 (7/91) <0 r
I.