Document 4xr6wym2a1R620vB7aJB5xma

- CRYOVAC DIVISION | W. R. GRACE&CO. | DUNCAN, SOUTH CAROLINA 29334 14 December 1972 TO: Task Group for PCB Analysis in Flexible barrier Mat> rials - Sub-Committee K2.30 . . RE; Minutes of Task Group Meeting, 30 November 1972 MEMBERS: Borman Bornstein -- CRYOVAC ' %/Oohn Gobi or - Dow v/6ordon Patterson/John Ness - duPont Irving Russoff/Tony Gross - NABISCO Scott Tucker - Monsanto \ v/Goorge White - Tteynolds Jim Ye.ransian - General Foods CC: R. J. Powell - duPont The first Task Croup meeting was held at the CRYOVAC headquarters in Duncan, SouHi Carolina, on 30 November 1972. The foil sing Task Croup members were present: Gordon Patti rson, John Ness, Ccm ge Wr.tc, John Coble." and Norman Bernstein. Ecu It- Reo and I.eRoy r.b of CrVOVAG also participated in the discussions. The discussion: covered vaiious aspects of PCB analysis in polymeries; 1. Polymeries to be Studied Methodology for the following polymers appeared to be of greatest interest: polyolefins, saran, PVC, ionomers and p lystyrene. II. Extraction Procedures Two general procedures for removing PCB were menti:ned as being employed by the participants: (1) vacuum distillation and (2) extraction. It was recognized that the solvents* the physical .late of the sample and the time- and temperature conditions of extraction, would have to he established and that these factors might vary dope ding upon the polymer being analyzed. ' 111. Clean-up Procedures The following procedures were mentioned: A. Florisil column deactivated with 2% water. B. Activated carbon column. 02771*8 TOWOLDMONOQ54330 14 December 1972 Page 2 C. Reaction with alcoholic KOH followed by extraction with n-hexane and an II2SO4 wash. D. Pyrolysis for the elimination of interfering compounds having a lower thermal stability than the PCBs. IV. Quantitative Analysis It was agreed that a gas chromatographic procedure employing a 63Ni electron capture? detector should be employed, The represented laboratories used DC-200, OV-17 or OV-210 columns in both glass and stainless steel. V. Calculations The following methods for obtaining results from the chromatograms were discussed: A. Using a single peak and referencing it against that peak in a standard against standard samplcsof one or more Aroclors. [ C. Calculating the concontrati 0:1s of each o.omponeiV' peak by peak or alternatively using only the major peaks, peak 1 peak.' VJ . Quail i alive An-.lysis ' Methods for validating whether unknown peaks are i;- fact. PCI', wen; briefly discussed. Methods mentioned were substant iati'. . y Mass Spectrometry, elemental analysis and corroboration using, a hydiu.. n flame detector. VII. Program . . The Task Group would begin by determining' the into laboratory agreement of the results of the analysis of prepared solutions c vujions Aroclors in n-hexane employing a tentative GC-EC method as v 'll as a sclr-me for calculating results both of which accompany this r? -rt.. The tentative method employs a 10% DC-200 6 ft. x 4 mm ID, colum. d injection port and detector temperatures of 32.5C and a column ter. erature of 200-225 C. Five different samples are to be sent to each Task Gnr member for analysis by the tentative standard method. The round robin 'saim <?.; will also be analyzed by standard procedures employed by the variouf laboratories to delcn i ne the criticality of a uniform method. It was noted in \ discussion that a given Aroclor will vary from lot to lot, the degree or variation vas unknown. In order to assess the degree of variation and its affo t: upon the reported results, it was agreed that samples of Aroclor 1242 ani 1254 employed by CKYOVAf. ns standards would also be sent to the Task Group memb a for comparison with the same materials in their possession. t ___ , NDB/sbm N. D. Bornste.i?, Manager Applied Research & Analytical Services 0277159 TOWOLDMON0054331