Document 4vw5OVVVaz78dgDVyQVj3d23e

TECHNICAL BULLETIN CATALOG PACKAGED OIL-FIRED BOILERS . FORCED HOT WATER PLAINTIFF'S EXHIBIT ASI-67 .Introducing the new VP(T) Packaged Boilers Eight outstanding features including a new concept in oil boiler operation--dual firing rates. ONE Each boiler comes v.-ith two nozzles. Install the cne that meets the immediate needs. Late:, you can add 15.000-20.000 ETUs just by switching nozsles. TWO New wet-base cast iron assembly o? sections. Vakes use oi a" heat-transfer areas THREE Tankless heate-s with the capacitj to meet the needs of growing families. Achieve maximum Tani-iess heater rating for each size boiler. - l`r I > FOUR Quiet 1725 RPM fiame-reiention burner. FIVE Flame-retention DH burner capable of operating at 12'A% C0S with combustion efficiency of over 0%. 1. controls--(including primary control) are mounted on fronl for easy service arid adjustment. Controls are factory-mounted and pre-wired. Primary control features light-sensing detector for quick response to ignition and flame failure. SIX Completely packaged to save onthe-job assembly lime. <To simplify handling, burner packaged separately.) SEVEN Fits minimum space of 1 5>'* to 2Sn" deep x 21'/}" wide bv high. - EIGHT Optional return tapping on rear section for zoning with circulators. : 2. model DH-F Arcoflame oil burner--flame-retention head is engineered to provide dean, efficient, economical firing. Slingmount hanging and EXACT-AIRE control simplify installation and adjustment. 3. water heater-large, copper coil tankless type, is inserted into 5" nipple port. 4. boiler sections-of durable cast ironjeat^ire vertical hue design with pmned surface area to extract maximum combustion heal. Wetbase construction eliminates need for special base. Sections are water tested at 75 psi 12% times water working pressure in accor dance with A.S.M.E.). 5. one-piice cleanout panelpermits cleaning of all flue surfaces from right side without disturbing burner, controls or accessories. 6. smartly styled jacket--made of sturdy steel in beige and brown fmisn, is assembled cn bcile: zt factory. 7. combustion target wall-- longlived. efficient refractory target wall used cn ai: VF co'ie's. It provides e.e* beet c str'tvt-cn to ccnbust'cn 'ea a'-c is factc.rynstaiied 8. wet-base construction-provides an extra heat-absorbing bottom surface. Waterways completely surround combustion area and extend beneath the boiler, making this boiler ideal for installation on combustible floors or basements. ELIMINAIRE* --a patented, cosisaving feature. This unique built-in air eliminator is integrally cast into the left-hand end section. Fu-nished with all VP(T) boilers, the ELIMINAIRE baffle diverts rising air bubbles into a tapping for connection to the expansion tan*. No externa: device is re puted to separate air and water, thus reducing both cost and instaifation time. Arcoflame. EXACT-AIR and ELIMINAIRE are trademarks of AMERICAN-STANDARD Technical Data Number of Section* Water Content Cal*. 3 15.6 4 20.0 5 24.a Heal Trn*fer Service Sq. Ft. 14.9 21 5 28.1 f; RATINGS--VPT Boilers-packaged units with factory installed tankless heaters Model No. (rots l=B=R output (MBH) -,=i=it burner capacity no. of (0h) aectiona | tinkle** tank!*** beater heater Icapaclty no. | (|pm)* net l=B=R ratine (MBH) net rating tq. ftwater burner used nozzle. size -- chimney . size VPT-115 115.0 1.05 100.0 667 1.00--60 semi-solid 8"* 8M* 15' 3 130 3K 0H-4F1 and ' VPT-J30 130.0 1.15 113.0 753 1.10-60 semi-solid 8" x 8" x 15' VPT-170 170.0 jVPT-190 190.0 1.50 1.70 4 147.8 9SS 1.50-80 solid 8" x 8" a 15* 131 4y. DH-5F2 and 165.2 1.102 1.65-80 solid 8"* 8"x 15 VPT-230 230.0 2.05 200.2 1.333 2.00--60 semi-solid 8" x 8" x 15* 5 132 6 * "I - r DH-5F3 and VPT-250 25o'o 2.25 217.4, 1.449 2.25--60 semi-solid 8"x 12"x 15* VP Boilers--packaged units less tankless heaters flfi VP-115' h5.0 100 0 1 VP-130 130.0 ; 1.15 3 113.0 * 667 ~ 753 11.00- 60 semi-solid 8" x 8" x 15' 1.10-60 semi-solid 8" x 8" x 15* VP-170 170.0 1.50 1 VP-190 ; 190.0 VP-230 ! 230.0 i i. | 1.70 ; : 2.05 1 VP-250 j 250 0 I 2.25 i 1 1 147.8 985 % DH-5F2 1652 11,102 1.50-80 solid and 1.65-60 solid 8"x 8*'x 15* 8"x 8"x 15* 1 1 200.2 1.333 1 !_____________ 1 1 217.4 jl.449 1 1 2.00-60 semi-solid 8" x 8*' x 15' 2.25-60 semi-solid 8"x 12"x 15* GPM water from 40r to 140F wth 2COF boiler water temperature - intermittent draw. VP-115 VP-130 VP-170 VP-190 VP-230 VP-250 1 j3 i 5 i j 16K i 8T/ 6'K. 9 K 39 26 28 i j 22)e irx. 6'K. 15X 39 26 34 J j 26X 1 * /it 7'X. 2lH 39 26 40 560 670 780 VP packaged oif-fired boilers I minimum piping recommendations forced hot water Procedures for filling loop Heetrim system: 1. Cicse all zone valves except zone to be purged 2. Open boiler1 Srjfn'valve. 3. Open fill valve.- t - * 4. Close purge. va.ive. 5. Vent air froci.boiler by. jianuatly opening.relief valve. r" 6. Open second-valve to be purged Close first zener After second zone is purged open thied zone valve and close second zone. Repeat for as many zones as in system. (NOTE: Always have one zone valve open.) 7.Whet) all zones have been, purged, close boiler drain cock. i. When water appears at relief valve, release lever and ailowr- to close. - 9.Continue filling until pressure gauge reads approximately 12 lb$,/sq...in.-Close fifl valve. 10. Open purge valve. ' NOTE: For a single loop Heatrim system, no additional vents, cocks, vaVe;. ' drains or other accessories are - required--with one exception, if tankless heater is used and Heatrin is above the boiler outlet, a fio-.-. check valve must be installed to prevent gravity circulator. oener#i scnemanc snowing mutig 10 cumyonems Packaged oil boiler less water heater wiring diagram with reverse-acting circulator control and constant ignition 24 VOLT THERMOSTAT GRD. yinE~~ OOTTED LINES / HOf) NOT FURNISHED 66 12 HONEYWELL R8182F OR R8182E COMBINATION CONTROL FF 9 GK3 CIRCULATOR <u TT B, BC]C 999 WIRE COLORS B-BLACK W-WHITE (HIGH LIMIT CONTROL SETTING APPROX. 210) (CIRCULATOR CONTROL SETTING APPROX. 100 R8182F ONLY) WIRE NUTS NOT FURNISHED C554A FLAME DETECTOR 24 VOLT THERMOSTAT GRD. DOTTED LINES / HOf, i NOT FURNISHED 66 12 HONEYWELL R8182 D COMBINATION CONTROL z C WIRE COLORS B-BLACK W-WHITE T T (HIGH LIMIT CONTROL SETTING APPROX. 210) (LOW LIMIT CONTROL SETTING APPROX. 190) WIRE NUTS NOT FURNISHED y- C554A / FLAME ' DETECTOR CIRCULATOR Packaged oil boiler with water heater wiring diagram for constant ignition AMERICAN STANDARD PLUMBING / HEATING P.O. Box 2003. New Bruniwick. NJ. 08903 Turn No. 7283-3 13/731 Wo . U.IA.