TECHNICAL BULLETIN CATALOG
PACKAGED OIL-FIRED BOILERS . FORCED HOT WATER
PLAINTIFF'S EXHIBIT ASI-67
.Introducing the new VP(T) Packaged Boilers
Eight outstanding features including a new concept in oil boiler operation--dual firing rates.
ONE Each boiler comes v.-ith two nozzles. Install the cne that meets the immediate needs. Late:, you can add 15.000-20.000 ETUs just by switching nozsles.
TWO New wet-base cast iron assembly o? sections. Vakes use oi a" heat-transfer areas
THREE
Tankless heate-s with the capacitj
to meet the needs of growing
families. Achieve maximum
Tani-iess heater rating for
each size boiler.
-
l`r I >
FOUR Quiet 1725 RPM fiame-reiention burner.
FIVE Flame-retention DH burner capable of operating at 12'A% C0S with combustion efficiency of over 0%.
1. controls--(including primary control) are mounted on fronl for easy service arid adjustment. Controls are factory-mounted and pre-wired. Primary control features light-sensing detector for quick response to ignition and flame failure.
SIX Completely packaged to save onthe-job assembly lime. <To simplify handling, burner packaged separately.)
SEVEN Fits minimum space of 1 5>'* to 2Sn" deep x 21'/}" wide bv
high. -
EIGHT Optional return tapping on rear section for zoning with circulators. :
2. model DH-F Arcoflame oil burner--flame-retention head is engineered to provide dean, efficient, economical firing. Slingmount hanging and EXACT-AIRE control simplify installation and adjustment.
3. water heater-large, copper coil tankless type, is inserted into 5" nipple port.
4. boiler sections-of durable cast ironjeat^ire vertical hue design
with pmned surface area to extract maximum combustion heal. Wetbase construction eliminates need for special base. Sections are water tested at 75 psi 12% times water working pressure in accor dance with A.S.M.E.).
5. one-piice cleanout panelpermits cleaning of all flue surfaces from right side without disturbing burner, controls or accessories.
6. smartly styled jacket--made of sturdy steel in beige and brown fmisn, is assembled cn bcile: zt factory.
7. combustion target wall-- longlived. efficient refractory target wall used cn ai: VF co'ie's. It provides e.e* beet c str'tvt-cn to ccnbust'cn 'ea a'-c is factc.rynstaiied
8. wet-base construction-provides an extra heat-absorbing bottom surface. Waterways completely surround combustion area and extend beneath the boiler, making this boiler ideal for installation on combustible floors or basements.
ELIMINAIRE* --a patented, cosisaving feature. This unique built-in air eliminator is integrally cast into the left-hand end section. Fu-nished with all VP(T) boilers, the ELIMINAIRE baffle diverts rising air bubbles into a tapping for connection to the expansion tan*. No externa: device is re puted to separate air and water, thus reducing both cost and instaifation time.
Arcoflame. EXACT-AIR and ELIMINAIRE are trademarks of AMERICAN-STANDARD
Technical Data
Number of
Section*
Water Content
Cal*.
3 15.6
4 20.0
5 24.a
Heal Trn*fer Service
Sq. Ft.
14.9
21 5
28.1
f;
RATINGS--VPT Boilers-packaged units with factory installed tankless heaters
Model No.
(rots l=B=R
output (MBH)
-,=i=it burner capacity no. of (0h) aectiona
| tinkle** tank!*** beater heater Icapaclty
no. | (|pm)*
net l=B=R
ratine (MBH)
net rating
tq. ftwater
burner used
nozzle. size
--
chimney . size
VPT-115 115.0 1.05
100.0 667
1.00--60 semi-solid 8"* 8M* 15'
3 130 3K
0H-4F1
and '
VPT-J30 130.0 1.15
113.0 753
1.10-60 semi-solid 8" x 8" x 15'
VPT-170 170.0
jVPT-190 190.0
1.50 1.70
4
147.8 9SS
1.50-80 solid 8" x 8" a 15*
131 4y.
DH-5F2
and
165.2 1.102
1.65-80 solid 8"* 8"x 15
VPT-230 230.0 2.05
200.2 1.333
2.00--60 semi-solid 8" x 8" x 15*
5 132 6 * "I - r
DH-5F3
and
VPT-250 25o'o 2.25
217.4, 1.449
2.25--60 semi-solid 8"x 12"x 15*
VP Boilers--packaged units less tankless heaters
flfi
VP-115' h5.0
100 0
1
VP-130 130.0 ; 1.15
3
113.0
*
667
~ 753
11.00- 60 semi-solid 8" x 8" x 15' 1.10-60 semi-solid 8" x 8" x 15*
VP-170 170.0 1.50
1
VP-190 ; 190.0
VP-230 ! 230.0 i
i.
| 1.70 ; : 2.05
1
VP-250 j 250 0 I 2.25
i
1 1
147.8 985
% DH-5F2 1652 11,102
1.50-80 solid and
1.65-60 solid
8"x 8*'x 15* 8"x 8"x 15*
1 1 200.2 1.333
1 !_____________
1
1 217.4 jl.449 1 1
2.00-60 semi-solid 8" x 8*' x 15' 2.25-60 semi-solid 8"x 12"x 15*
GPM water from 40r to 140F wth 2COF boiler water temperature - intermittent draw.
VP-115 VP-130 VP-170 VP-190 VP-230 VP-250
1 j3
i
5
i
j 16K i
8T/ 6'K.
9 K 39 26 28
i
j 22)e
irx.
6'K.
15X
39
26
34
J
j 26X
1 * /it
7'X.
2lH
39
26
40
560 670 780
VP packaged oif-fired boilers
I
minimum piping recommendations forced hot water
Procedures for filling loop Heetrim system:
1. Cicse all zone valves except zone to be purged
2. Open boiler1 Srjfn'valve. 3. Open fill valve.- t - *
4. Close purge. va.ive.
5. Vent air froci.boiler by. jianuatly opening.relief valve. r"
6. Open second-valve to be purged Close first zener After second zone is purged open thied zone
valve and close second zone. Repeat for as many zones as in system. (NOTE: Always have one zone valve open.)
7.Whet) all zones have been, purged, close boiler drain cock.
i. When water appears at relief
valve, release lever and ailowr-
to close.
-
9.Continue filling until pressure gauge reads approximately 12 lb$,/sq...in.-Close fifl valve.
10. Open purge valve.
' NOTE: For a single loop Heatrim system, no additional vents, cocks, vaVe;.
' drains or other accessories are - required--with one exception, if
tankless heater is used and Heatrin
is above the boiler outlet, a fio-.-. check valve must be installed to prevent gravity circulator.
oener#i scnemanc snowing mutig 10 cumyonems
Packaged oil boiler less water heater wiring diagram with reverse-acting circulator control and constant ignition
24 VOLT THERMOSTAT
GRD.
yinE~~
OOTTED LINES / HOf)
NOT FURNISHED
66
12
HONEYWELL R8182F OR R8182E COMBINATION CONTROL
FF 9
GK3
CIRCULATOR
<u TT B, BC]C 999
WIRE COLORS B-BLACK W-WHITE
(HIGH LIMIT CONTROL SETTING APPROX. 210) (CIRCULATOR CONTROL SETTING APPROX. 100 R8182F ONLY)
WIRE NUTS NOT FURNISHED
C554A FLAME DETECTOR
24 VOLT THERMOSTAT
GRD.
DOTTED LINES / HOf, i
NOT FURNISHED
66 12
HONEYWELL R8182 D
COMBINATION CONTROL
z
C
WIRE COLORS B-BLACK W-WHITE
T T (HIGH LIMIT CONTROL SETTING APPROX. 210) (LOW LIMIT CONTROL SETTING APPROX. 190) WIRE NUTS NOT FURNISHED y- C554A / FLAME ' DETECTOR
CIRCULATOR
Packaged oil boiler with water heater wiring diagram for constant ignition
AMERICAN STANDARD
PLUMBING / HEATING
P.O. Box 2003. New Bruniwick. NJ. 08903
Turn No. 7283-3 13/731 Wo . U.IA.