May 14, 1981
TO: DR. Y. L. POWER - PPD, Washington Works
FROM: S. S. S FAFFORD V L I '
ANALYSIS OF BLOOD SAMPLES FOR PERFLUOROOCTANOATE (Job No. 810-190; PRAL Nos. 81-1420-81-1467; Notebook Nos. E2251A.E26238)
As requested in your letter of 4/8/81 to L. J. Papa, the 48 blood samples submitted then have been analyzed for perfluorooctanoate (Cg). Results and sample identification are given in the attached table.
As noted there, the analysis was done using a gas chromatographic method specific for Cg (Lab Method Number ES-567) but results have been reported as ppm F for comparison with total organic fluorine analyses. Precision is 10% relative standard deviation over most of the concentration range, somewhat less at the lowest values. The lower limit for quantitation is 0.007 ppm F (0.01 ppm perfluorcoctanoic acid), with a detection limit of 'v 0.004 ppm which can be distinguished from the reagent background hut not well quantitated.
Please contact me (772-4440) or L. J. Papa (772-2745) if you have any questions regarding the analyses. General questions on blood sampling can be directed to J, W. Raines or L. F. Percival.
Attachment jah
Keywords : Perfluorooctanoic Acid Perfluorooctanoate Blood Analysis GC
There's a w o rld o l things we're doing som ething about U000b4
EXP000003
EID713817
TABLE I CONCENTRATION OF PERFLUOROOCTANOATE IN BLOOD (a)
Sample PRAL No.
81-1420
Date Sampled 4/1/81
81-1421 81-1422 81-1423 81-1424 81-1425 81-1426 81-1427 81-1428 81-1429 81-1430 81-1431 81-1432 8-1433 81-1434 81-2435 81-1436 81-1437 81-1438 81-1439 81-1440 81-1441 81-1442 81-1443 81-1444 81-1445 81-1446 81-1447 81-1448 81-1449 81-1450 81-1451
4/1/81 4/2/81 4/2/81 4/3/81 4/3/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81
P.R.No.
4443
4101 4226 4449 4530 4621 4490 4283 WS WS 4109 4316 4282 4243 4520 4177 WS 4293 WS 4225 4182 4250 4547 4181 4551 4514 4624 4444 4251 WS 4111 WS
Name
GC Analysis Date Analyzed
4/11/81 4/15/81
[Cg], y g P/g 61ooctb
0.078 0.074
1.5
0.013 0.048 0.62 0.13 0.072 0.051
0.11
0.061 0.19 1.0 5.1 0.44 0.052 0.23 0.11 0.17 0.31 0.054 0.077 0.31 4.3 0.64 1.30.14 0.57 0.18 0.15 0.83 3.8 0.22 (c)
*REDACTED*
EXP000004
EID713818
000065
! TABLE I (CONT"D) CONCENTRATION OF PERFLUOROOCIANOATE IN BLOOD (a)
Sample PRAL NO. 81-1452 81-1453 81-1454 81-1455 81-1456 81-1457 81-1458 81-1459 81-1460 81-1461 81-1462 81-1463 81-1464 81-1465 81-1466 81-1467
Date Sampled 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/6/81 4/7/81 4/7/81 4/7/81 4/7/81 4/7/81 4/7/81 4/7/81 4/7/81 4/7/81 4/7/81
P.R.l 4650 4448 4409 4400 4631 4234 4172 4382 4518 4299 4249 4300 4290 WS 4364 WS
Name
GC Analysis__________ :____________fb) Date Analyzed [C. j , yg F/g blood
4/16/81
0.019
4/18/81
0.11
4/18/81
0.14
4/18/81
2.1
4/18/81
0.19
4/18/81
4.3
4/20/81
4.5
4/20/81
0.81
4/23/81
1.7
4/20 & 4/24/81 4.5
4/20/81
1.9
4/23/81
2.4
4/20/81
0.10
4/20/81
0.47
4/24/81
3.6
4/20/81
0.092
(a)
Analysis as described in H
n^ , x u x u iix v w U y u a s o u t u iu a L L / g t a ^ u x u
y u l. o
-t / v / w i / ) l.
c iit .
packed column GC analysis with perfluoro-n-octanoic acid as calibration standard.
(b) Although the analysis is specifically for perfluorooctanoate (acid or salts), concentrations are given in ppm fluorine for comparison with the results of total organic fluorine analyses. (ppm F = 0.688 x ppm perfluorooctanoic acid) Estimated uncertainty is + 10% relative standard deviation. The lower limit for quantitation is 0.007 pgF/g. The detection limit is 'L 0.004 U.gF/g, but concentrations in that range cannot be well quantitated and are reported as < 0.007. "None detected" is reported for samples with [Cg] < 0.004 ppm, which cannot be distinguished from reagent background.
(c) In GC analysis of this sample one unusual large peak was observed in the region of interest, but no interference with the Cg peak was apparent.
REDACTED*