INDUSTRIAL HYGIENE QUARTERLY REPORT LAPORTE PLANT ANNUAL REPORT 1994 A) Personnel Monitoring and Data Information: 1 ) Vinyl Chloride a) No. Samples completed 146 b) No. Samples over action level 0.5ppm-8hr 02 c ) No. Sanples over OSHA PEL 1 ppm 8hr. TWA 02 d). No Samples over OSHA PEL 1 ppm 8hr. TWA w/o Respiratory protection. 02 2) Ethylene Dichloride a) No. Samples completed. .....JL.A6. b) No. Samples over OSHA PEL 50ppm-8hr. TWA 00 c) No. Samples over the ACGIH TLO 10PPM 8hr. TWA. 00 d) No. Samples over lOppm 8hr. TWA w/o PPE 3) Noise a) No. Personnel Samples Completes. b) No. Samples over 90db(A) 8hr . TWA c) No- Samples Over Action Level 85db 8hr. d) No. Samples over 85db 8hr. TWA w.O PPE e) No. Samples with breaktrough(115db) 00 19 05 06 > i, A oo 01 r : Hearina Conservation. a) No. Audiograms Completed No. Required by OSHA c) No. Audiograms Identified in (b) showing a (confirmed) Age Adjusted STS Shift. d) No. Audiograms Identified in (C) showing Adjusted (confirmed) 25db or more shift in either ear.(Avg. 2K,3K,4K). 127 1?7 04 1100 ngc INDUSTRIAL HYGIENE QUARTERLY REPORT L^PORTE PLANT ANNUAL REPORT 1994 C ) Medical Survei1 lance Data and Informalion. 1) No. of VCM related Blood analyses Performed 127 2) No. of Abnormal Findings Which Have Been Med ically determined to be potentially related to VCM. 3) No. of Physical Examinations completed. -QO.. --132 a) Annual Physicals - 127 b) Semi-Annual examinations UZ c) Pre-employment examinations D) Randon Drug Screening Tests Completed 1) DOT Tests 129 2) Non DOT Tests 136 _ 3) For Cause 4) post injury E ) OSHA RECORDABLE ACCIOENTS 1) Laceration thumb - 07 -m___ ..q? 2) Chemical Burn ATTACHMENT 1) Over esposure to VCM. Sample started at 0530, terminated at 1800. TWA 3.16 ppm. 2) Place of exposure-ITC Docks. 3) Task-loading ship and obtaining lab. samples. 4) Employee was not aware of any unusual activites. No alarms were evident- No-protection equipment was worn. * 5) Employee was offered Medical Examination, which was denied in light of the fact, that annual physicals will be forthcoming in 6-8 weeks. 6) Employees to be monitored for several docking to in order to determine if this is an isolated incident. NGC 15523 ATTACHMENT B.r_ 1) Overexposure to UCM. Sample started at 1800 hours, terminated at 0600. 2) Place of exposures UCM tank farm. 3) Task: Opening a bleed valve which he thought was under a nitrogen purge, whenhe realized his mistake he decided that it would take to long to get a SCBA or airline respirator. He took care of the problem with out the bebefit of respiratory protection. 4) Employee was offered medical examination, which he declined on light of the fact that annual exam inations will be forthcoming in 6 weeks. 5) Additional stations, with airline respirators, have been established in the area. All personnel were made aware of the changes and a monthly inspection schedule has been instituted. 6) A survey of other critical areas of this plant was made and additional stations have been installed in each area. ATTACHMENT Cs Audiogram evaluation( excluding Pre-employment) 1) Poss. Conductive loss 2.3* 2) Poss. Noise induced loss 52.3% 3) Poss. Mixed loss S.5% 4) Poss.other types of los. 0.0% 5) Normal hearing 39.3% 6) Employees medically evaluated for STS. 02 Both cases determined not to be job related by retest and history. NGC 15524