Document 4v1jGpXb5ZL9zRQkddjogQJNN

wJ Interoffice Communication To From A. H. Sather J. V. Uptain Date February 9, 1978 Subject CONTINUOUS MONITORING SUMMARY FOR JANUARY, 1978 Stream No. 1 2 3 4 5 6 7 8 9 10 % of Total Laboratory Unit Range, PPM .0 - 0.5 0.5 - 1.0 1.0 - 5.0 + 5.0 % over 5 . 744 0 0 0 0.0 Dryer Building Unit 744 0 0' 0 0.0 744 0 0 0 0.0 744 744 744 0 00 0 00 0 00 0.0 0.0 0.0 744 744 744 744 0000 0000 0000 o o 0.0 0.0 0.0 100.0 0.0 0.0 0.0 - Range, PPM .0 - 0.5 0.5 - 1.0 1.0 - 5.0 + 5.0 % over 5 645 1 1 1 0.15 643 2 2 1 0.15 645 1 1 1 0.15 Large Reactor'Unit 644 2 1 2 0.31 644 644 22 1 0 1- 2 0.15 0.31 643 643 644 312 110 112 0. 15 0.15 0.31 in by-Operations 645 1 1 1 0.15 99.4 0.3 0.1 0.2 - Range, PPM .0 - 0.5 0.5 - 1.0 1.0 - 5.0 + 5.0 % over 5 Tank Farm Unit 672 674 642 645 663 602 47 36 62 55 56 82 23 28 35 38 16 48 265 5 9 12 0.27 0.81 0.67 0.67 1.21 1.61 This unit was down on 1/14/78. Range, PPM .0 - 0.5 0,,5 - 1.0 CL.O - 5.0 +. 5.0 % over 5 613 559 615 646 619 568 43 59 32 19 42 67 16 40 21 7 9 33 0 14 5 0 24 0.0 2.08 0.45 0.0 0.30 0.60 This unit was down 1/13 and 1/15. 660 45 32 7 0.94 660 58 25 1 0.13 662 48 29 5 0.67 731 9 4 1 _Q. L3- 575 637 655 657 _ 54 19 11 9 33 16 6 3 9000 1.34 0.0 0.0 0.0 88.9 6.7 3.7 0.7 - 91.5 5.3 2.7 0.5 - irald V. Uptain c: GGD, Dept. Heads, DAK-Houston, ODS-Ponca City jf DTH 000050454 ABERDEEN LABORATORY VCM CONTINUOUS MONITORING UNIT TRENDS -PERCENTAGE OF SAMPLES WITHIN CONCENTRATION RANGES OS El 5o ziO? *Ui 5 v>a (Wu*Ai Zu < u. u>jPU. IA I 2C DTH 000050455 ABERDEEN DRYER VCM CONTINUOUS MONITORING UNIT TRENDS -PERCENTAGE OF SAMPLES WITHIN CONCENTRATION RANGES oo> CNJ CO to in zo jo > X< (0 2 o z 0 ?> 8UJ Q01 *_, tt UJ Sfc en3X DTH 000050456 ABERDEEN LARGE REACTOR VCM CONTINUOUS MONITORING UNIT TRENDS -PERCENTAGE OF SAMPLES WITHIN COCENTRATION RANGES 12 10 8 6 4 2 0 12 10 8 6 4 2 0 12 10 8 6 4 2 0 DTH 000050457 ABERDEEN VCM TANK CONTINUOUS MONITORING UNIT TRENDS -PERCENTAGE OF SAMPLES WITHIN CONCENTRATION RANGES 12 10 8 6 4 2 0 12 10 8 6 4 2 0 12 10 8 6 4 2 0 in August, 1976 DTH 000050458 HONEYWELL CONTINUOUS MONITOR STREAM LOCATIONS Laboratory Stream No, Location 1 Mounted on middle bagger in warehouse , 2 Mounted in Quality Control Laboratory 3 Mounted on Line I Blenders '4 Mounted on Line III mill 5 Mounted in Development Laboratory 6 Mounted on Welex Deck in Dry Blend 7 Mounted in Dry Blend Control Room 8 Mounted on Dry Blend Blender 9 Mounted in Section B of East warehouse 10 Mounted on shrink wrap unit Large Reactor Area Stream No. Location 1 Mounted at east side of Control Room 2 Mounted at 401 VCM Receiver 3 Mounted on 1st floor at H-5 Reactor 4 Mounted on second floor of Large Recovery System 5 Mounted above Sweco 6 Mounted on 1st floor, bottom of D-300 7 Mounted at top of D-300 8 Mounted at bottom of D-500 9 Mounted at top of D-600 10 Mounted on inlet air to Control Room Dryer Building Stream No. Location 1 Mounted on 1st floor between #5 8 #6 activator 2 Mounted in Dryer Control Room 3 Mounted on 1st floor between #7 5 #8 activator 4 Mounted on 2nd floor sifter area east of #6 5 Mounted on 1st floor under slurry hose station 6 Mounted on 1st floor between #7 $ #8 Birds 7 Mounted on 1st floor between #4 #5 Birds 8 Mounted on 2nd floor between # 7 #8 Birds 9 Mounted on 2nd floor between #4 #5 Birds 10 Mounted on V-10 bagger VCM Tank Farm Stream No. Location 1 Mounted on bottom of D-600 reactor 2 Mounted at #3 Recovery System 3 Mounted at South unloading station 4 Mounted at respiratory air inlet 5 Mounted at middle unloading station 6 Mounted ar North unloading station 7 Mounted at Compressor shed 8 Mounted at blowdown tank - South end 9 Mounted at North Receiver 10 Mounted at Gear Room (West side) DTH 000050459