AR226-2448 INTEROFFICE MEMORANDUM Date: From; Dept: Tel NO: 16-Sep*1997 03:07pm Gregory A Chapman CHAPMAGA Fluoroproducts 304-863-2535 TO: See BelOM Subject: Action Items from 9/16 C-8 Sampling Meeting 1. Data analysis of Nichols' c-8 sampling project Develop format for data entry 6AC Have data entered RRM Analyze Data 6AC 2. Insure proper PPE is used in the PP/Disp. Wax Room CJ6 3. Reduce c-8 exposure risk from Granular ingredients hood Implement short-tern) measures (fix leak, etc.) CJG Implement long-term measures (surfactant addition system) RJ2 4. Mork Mith Hailey to move B162 2nd floor smoking area RRM 5. Install filter on FP dryer C-8 vent RJZ 6. Insure proper maintenance is performed on FP dryer as noted in incident investigation FDL 970015 See Writs Up 7. Set standard in the BTO to not near clothes contaminated RRM Mith dispersion (or other c-8 containing materials) 8. Resolve exposure potential associated with draining of FP float tank (automated valve?) CJ6/RJZ 9. Insure proper PPE is used for changing air filters with CJQ g emphasis on the roof of B162. N 10. Manage C-8 exposure potential in vicinity of C-8 scrubber o\ Understand G*8 exposure potential on B162 roof & S surrounding areas R<JZ institute appropriate administrative controls & PPE CJQ Take additional air samples to complete mapping AJP/BSD 11. compare Nichols' data Mith previous data (particularly blood data) and look for correlations AJP 12. Take Mipe samples in FEP clean room. BSD 13. if C-8 is going to continue to be used in FEP, investigate engineering controls on C*8 levels. By Loch 14. Evaluate Nichols' data and recommend additional sampling BSD needs. EID093175 EIDOS3175