3rd Quarter Safety & Housekeeping Inspection - Material Handling
TO : Frank Bales AB-1
CC SHAC
Glen Vogtman
AB-1
Tom Hartnett
AB-1
Rusty Wilson
AB-1
Charles Loney
AB-1
R. Bledsoe
AB-1
G. W. Bostick
0-18
R. A. Forsthoffer 0-5
Dan Nelson
330
Bob Bohmler
SS-9
The 3rd Quarter Safety & Housekeeping Inspection for Material Handling was conducted by the inspection team of Ray Forsthoffer, Bob Bohmler, Dan Nelson, and Bob Hammann on August 14. The department was given a "good" rating. More time was spent in the dock area during this inspection than in the other areas of Material Handling. The next inspection will emphasize the tank car/ tank truck areas more. The following items need to be corrected:
Safety
c 1. Recommend installation of signs to indicate the correct exit for seamen at Dock #1 - possible use of international "No Pedestrian" sign.
2. Hoses need to be inspected at Dock #5.
3. Replace rope at Dock #5.
4. Replace life ring east end of Dock #1.
5. Breathing air manifold by Dock #1 Shack - 3 of 4 connections are frozen and manifold on lower deck in the middle - all connections are frozen.
6. Utility station by northeast corner of building on Dock #1 needs steam and water lines labeled.
7. Need new sign by naphthalene drum blowdown area.
8. Hoses need to be replaced on hoists on all docks.
9. Should hoists at docks be included on the plant hoist inspection?
10. Are 3,000 lb booms at Dock #2 inspected on a set frequency?
11. Replace crowsfeet in styrene rack area.
12. The AN rack: LAM001748
SC 000550
3rd Quarter Safety & Housekeeping Inspection - Material Handling
Page 2.
a) Spot 11 - chain wired to handrail. b) Check crowsfeet. c) Loose wires in telephone box near spot 3. d) Need to check spots 2 and 3 for grating replacement.
13. Incorrection inspection tape on nitrogen hose in styrene rack.
Housekeeping
+1. Styrene rack in excellent condition.
2. Trash in 910 21T104 sump.
3. Unplugged drains under slop tanks at Dock #1.
4. Straighten out storage building in styrene rack area.
5. AN rack - boxes holding maintenance equipment all along rack need to be cleaned out.
6. Tarp in #4 fire extinguisher box at Dock #5.
7. Sandpaper in #2 fire extinguisher box at Dock #2.
Please respond to this inspection in writing to G. W. Bostick with a copy to Steve Monel a by 9/7/84.