DOW CHEMICAL U.S.A.
50983^
TEXAS DIVISION FREEPORT, TEXAS 77541
ENVIRONMENTAL HEALTH REPORT
AIRBORNE ASBESTOS SURVEY CHLOR ALKALI UNIT II, OYSTER CREEK DIVISION
file no. OCD-331_______ DATE. April 15. 1974 AUTHOR _ H. N. Edwards
PfCHECKED
.TF <f//S/74
Summary
A survey for airborne asbestos was made at the Chlor Alkali Unit of the Oyster Creek Division. All analyses were below the levels required for the asbestos standard established by the Occupational Safety and Health Act (OSHA).
ST0650993
Distribution
R. M. Webb
OCD
C. E. Caldwell OCD
R. C. Miller OCD
R. E. Flake B-101
J. D. Laman B-1226
* H. R. Hoyle - 1707
Bldg.
Midland
* C. L. Sercu - Cleveland * R. G. Vaughn - Plaquemine
File (2)
* F. D. Axe - Pittsburg * R. R. Langner- 607Bldg., Midland
AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY
File OCD-331
-2-
i66US90Ii
INTRODUCTION:
The Occupational Safety and Health Act (OSHA) requires that occupational exposure to airborne asbestos dust be controlled so that no worker is exposed to more than 5.0 asbestos fibers per cubic centimeter of air based on a count of fibers greater than 5 micrometers in length. These are determined as a timeweighted average (TWA) exposure for an eight hour work day, and no peak concentrations of asbestos more than 10.0 fibers per cubic centimeter as determined by a minimum sampling time of fifteen minutes. This survey evaluated the airborne asbestos at the Chlor Alkali Unit of Oyster Creek Division.
METHODOLOGY:
The bulk storage of asbestos is located in a storeroom several hundred yards from the Chlorine Cells (Fig. 1). Each day enough asbestos is transported from the bulk storage to a temporary storage located between the cell blocks and on the cells (Fig. 2). As the asbestos is required it is carried onto the top of the cells, mixed in a large container, and used in that area (Fig. 3). Air samples were taken in each of these areas and a personnel monitor was worn by the Technician while mixing and using the material.
Airborne samples were collected using the Micronair permissible air sampling pump (Bendix Environmental Science Division, Baltimore, Maryland). The asbestos was collected by pulling air through a millipore filter. Flow rates for the pumps were calibrated at 2000 cubic centimeters per minute and the sampling times for the stationary pumps were fifteen minutes, while the personnel monitor was worn for thirty minutes. All analyses were done by Lee Martin B-1218.
RESULTS:
There were no asbestos levels that exceeded the limits establish ed by OSHA, (Table I). The highest level obtained was in the bulk storage area. In this area there was considerable loose dry asbestos.
File OCD-331
-3-
CONCLUSIONS:
Airborne asbestos measured during this survey was well below the current Threshold Limit Value (TLV).
RECOMMENDATIONS;
(1) Even though the concentrations of asbestos are below the TLV, care should always be used when handling the material.
(2) The bulk storage area should be used only for asbestos.
(3) The bulk storage area should be free of loose asbestos.
(4) There was some loose asbestos along side the cells. This should be removed.
(5) All clean up of asbestos should be performed by vacuum cleaners or wet cleaning method. No dry sweeping should be performed.
(6) Asbestos waste and scrap should be collected and disposed of in sealed bags or other containers.
(7) Medical surviellance is required on all personnel handling asbestos.
(8) Monitoring of this area should be done annually, and more frequently if work procedures change.
6 a fi 111 s
EHS HNE/bbs 4-15-74
TABLE I
AIRBORNE ASBESTOS
*
Fibers greater than 5.0 micrometers per cubic centimeter
LOCATION
NO. OF FIBERS
(1) (Fig.l) Bulk storage area-----------------------------------
1.97
(2) (Fig. 1) Bulk storage area---------------------------------------
0.80
(3) (Fig. 1) Bulk storage area--------------------------------------
0.14
(4) (Fig. 2) Temporary storage--------------------------------------
0.10
(5) (Fig. 2) Temporary storage--------------------------------------
0.01
(6) (Fig. 3) Downwind of asbestos work----------------------
0.25
(7) (Fig. 3) Downwind of asbestos mixing------------------
0.32
(8)
Personnel monitor---------------------------------
0.22
9660S9U1S
ST0650997
Fig. 1 Ashe, slos Storage
St ora g fc'
ST0650998
Fig. 2
On-jolo cxsbes-tos sio rage.
6660S901U
Fiq 2. Ce.ll arecL
50983
DOW CHEMICAL U.S.A.
________________________________________________________________________________________________________
TEXAS DIVISION FREEPORT, TEXAS 77541
ENVIRONMENTAL HEALTH REPORT
AIRBORNE ASBESTOS SURVEY CATHODE CLEANING UNIT OYSTER CREEK DIVISION
file no.
OCD-327
natf April 9, 1974
H.author N. Edwards
CHECKED
DATE____
Summary
A survey for airborne asbestos was made at the cathode cleaning unit. All analyses were below the levels required for the asbestos standard established by the Occupation Safety and Health Act (OSHA).
ST065 I 000
Distribution
M. E. Sanders OCD C. J. Barras OCD C. E. Caldwell OCD R. C. Miller OCD R. E. Flake B-101 J. D. Laman B-1226
* C. L. Sercu- Cleveland * R. R. Langner -607 Bldg.-Midland * X. G. Vaughn - Plaquemine File (2)
H. R. Hoyle 1707 Bldg. -Midland *F. D. Axe - Pittsburg
AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY
File No. OCD-327
-2-
INTRODUCTION
The Occupational Safety and Health Act (OSHA) requires that occupational exposure to airborne asbestos dust be controlled so that no worker is exposed to more than 5.0 asbestos fibers per cubic centimeter of air based on a count of fibers greater than 5 micrometers in length. These are determined as a time-weighted average (TWA) exposure for an eight hour work day, and no peak concentrations of asbestos more than 10.0 fibers per cubic centi meter as determined by a minimum sampling time of fifteen minutes. This survey evaluated the airborne asbestos at the cathode cleaning unit.
METHODOLOGY
The cathode cleaning area was surveyed and ten locations were selected as stationary points for monitoring (Fig.l). Four other samples were collected from a monitor worn by a Technician during four hours of work.
Airborne samples were collected using the Micronair permissible air sampling pump (Bendix Environmental Science Division, Baltimore, Maryland). The asbestos was collected by pulling air through a millipore filter. Flow rates for the pumps were cali brated at 1500 cubic centimeters per minute and the sample times for the stationary pumps were thirty minutes while the time for sampling of the personnel monitor was one hour each for four hours. All analyses were done by Lee Martin B-1218.
RESULTS
There were no asbestos levels that exceeded the limits established by OSHA, (Table I). This operation seems to keep everything damp at all times and therefore asbestos levels are low.
CONCLUSIONS
Airborne asbestos measured during this survey are well below the current Threshold Limit Values (TLV).
? T065 I 00 I
File No. OCD-327
-3-
RECOMMENDATIONS
(1) Even though the concentrations of asbestos are below the TLV, care should always be used when handling the material.
(4) When the weather is warm and outside the cleaning area is dry, another survey should be made. This would evaluate the levels created by the truck traffic along the roadways.
ST0651002
EHS HNE/bbs 4-9-74
TABLE I
AIRBORNE ASBESTOS Fibers greater than 5.0 micrometers per cubic centimeter
GOO I 99()ib
(1) (Fig.l) Change Room, dirty clothes area
0.30
(2) (Fig.l) Lunch Room, on table
0.16
(3) (Fig.l) On cathodes that have been cleaned
0.27
(4) (Fig.l) On wall (5' from floor)
0.86
(5) (Fig.l) Between motors (5* from floor)
0.67
(6) (Fig.l) On wall (5' from floor)
0.10
(7) (Fig.l) On cathodes - ready for cleaning
0.16
(8) (Fig.l) Along road on cathodes (5! from ground) 0.10
(9) (Fig.l) Along road on cathodes(4' from ground) 0.12
(10) (Fig.l) Along road on cathodes(4* from ground) 0.13
PERSONNEL MONITOR First hour------------------------------------------------------------------------- 0.73 Second hour----------------------------------------------------------------------- 0.13 Third hour--------------------------------------------------------------------- * Fourth hour----------------------------------------------------------------------- 0.10 * Filter became wet during work (unable to evaluate)
EHS HNE/bbs 4-9-74