Document 4aJQG6e996gep4VvkNp3r2dpe

vs 7/5 E. I. DU PONT DE NEMOURS AND COMPANY, INC. WILMINGTON, DEL. ENGINEERING DEPARTMENT THERMAL INSULATION SPECIFICATION NO. 8544 FOR VICTORIA PLANT SITE MAINTENANCE AND OR PROJECTS This speciicaCion has been furnished by E. I. du Pont de Nemours and Company, Inc. The information and know-how contained here in may not be reproduced without the written permission of Du Pont. Approved : Date : Approved : Date : Approved : Q l/J K tdLucJ INSULATION ENGINEER t Date: This specification supercedes all previously issued insulation specifications from the Engineering Department. This specification is issued on Project 1908. However it shall be used for subsequent Projects with updating as required. ISSUE DATEREV. DATE 10/15/84 DUP 0838653 1. o 1.1 1.2 2.0 3.0 3. 1 3.2 3.3. 3.4 3.5 3.6 3.7 3.8 3.9 3. 10 3.11 4.0 5.0 5.1 5.2 5.3 5.4 5.5 5.6 6.0 6.1 6.2 6.3 6.4 6.5 6.6 '6.7 6.8 7.0 7.1 7.2 7.3 7.4 7.5 7.6 7.7 8.0 8.1 GUIDE FOR USING THIS SPECIFICATION..................................................1 SPECIFICATION GUIDE .............................................................................. 1 INSULATION SYMBOLS .................................................................................... 2 -NOTES ANDEXCEPTIONS .................................................................................. 3 THERMAL INSULATION SYSTEM- CATEGORY ........................................ 4 CATEGORY NO. 1- SERVICE TEMP. 36 TO 80 F........................... 4 CATEGORY NO. 2- SERVICE TEMP. 80 TO 750 F......................... 5 CATEGORY NO. 3- PERSONNEL SAFETY ........................................... 6 CATEGORY NO. 4- SERVICE TEMP. -200 TO +35F ... 7 CATEGORY NO. 5- DUCTS- IN WET AREAS....................................8 CATEGORY NO. 6- TRACED PIPE.......................................................... 9 CATEGORY NO. 7- DUCTS, PIPE- IN DRY AREAS ... 10 CATEGORY NO. 9- NOISE - PERSONNEL SAFETY .... 11 CATEGORY NO. 10- NOISE - ENERGY CONSERV.............................. 12 CATEGORY NO. 12- FIRE PROTECTION........................................ 13 CATEGORY NO. 14- FACTORY PRE-INSULATED PIPE . . 14 MATERIAL INDEX ................................................................................................ 15 THICKNESS JNDEX . 25 TABLE C2 . . . ^ .'........................................................................................ 25 TABLE C4.......................................................................................................... 2 6 TABLE HI........................................................................................................... 27 TABLE H2.......................................................................................................... 2 8 TABLE H5..................................................................................................................29 TABLE H6................................................................................................................. 30 PIPE INSULATION.................................................................................................31 GENERAL CONDITIONS .............................................................................. 31 APPLICATION SPECIFICATION FOR THICKNESS INDICES <49> AND BELOW.(35 DEG.F & BELOW) TABLE C2 . . . 33 APPLICATION SPECIFICATION FOR THICKNESS INDICES <50> THRU <54> (35 THRU 80 F) TABLES HI, C2, H5, H6........................................................................................................................... 35 APPLICATION SPECIFICATION FOR THICKNESS INDICES ABOVE <55> (81 TO 1200 F) TABLES HI, H2, H5, H6 36 APPLICATION SPECIFICATION FOR TRACED PIPE FOR THICKNESS INDICES 55 THROUGH 96 (81 THRU 500 DEG. F) TABLES HI, H2...........................................................................................37 FINISH....................................................................................................................... 38 FIRE RESISTANT FINISH (WHEN SUPPLEMENTARY CODE LETTER Q IS USED)..................................................................................... 40 FACTORY PRE-INSULATED PIPE (WHEN SUPPLEMENTARY CODE LETTER F IS USED)..........................................................................41 EQUIPMENT INSULATION ......................................................................... 43 GENERAL CONDITIONS .............................................................................. 43 APPLICATION SPECIFICATION FOR THICKNESS INDICES 49 AND BELOW (35 DEG. F & BELOW) TABLE C2 ... 45 APPLICATION SPECIFICATION FOR THICKNESS INDICES <50> THRU <54> (36 TO 80 F)TABLES C2, HI, H5, H6 47 APPLICATION SPECIFICATION FOR THICKNESS INDICES 55 AND ABOVE (80 TO 1200 F)TABLES HI, H2, H5, H6 48 FINISH....................................................................................................................... 49 FIRE RESISTANT FINISH FOR EQUIPMENT (WHEN SUPPLEMENTARY CODE LETTER "Q" ISUSED)................................. 52 FIBERGLASS-REINFIOCED EPOXYRESINFINISH ... 54 DUCT INSULATION................................................................................................ 56 GENERAL CONDITIONS .............................................................................. 56 Oc u o co CO CcOn <n o> rlW'Hr : -up- q--^IITgsreii1 .- j----- .*, rL-r- ........ .. 8.2 8.3 8.4 9.1. 9.2 9.2.1 9.3 9.4 9.4.1 9.5 9.6 9.7 9.8 Page 2 APPLICATION SPEC. FOR DUCTS (SUPPLEMENTARY CODE LETTER "J") INSULATION OUTSIDE THE DUCT -OUTDOORS 57 APPLICATION SPEC. FOR DUCTS (SUPPLEMENTARY CODE LETTER "J") INSULATION OUTSIDE THE DUCT - DRY, LOW ABUSE AREAS.................................................................................... 58 FINISH FOR INSULATION OUTSIDE THE DUCT...................... 60 APPENDIX "A"- INSULATION SYSTEM SKETCHES FOR PIPE 63 APPENDIX "B"- HANGER ROD RAIN SHIELDS............................... 64 APPLICATION.......................................................................................... 64 APPENDIX "C"- INSULATION OF TRAPS.......................................... 65 APPENDIX "D"...................................................................................................... 66 SOFT TYPE REMOVABLE (REUSABLE) INSULATION COVERS FOR PIPING AND EQUIPMENT OPERATING UP TO 650 DEG. F...................................................................................................... 66 APPENDIX "E"- INSULATION SYSTEM SKETCHES FOR TRACED PIPE...................................................................................................... 71 APPENDIX "F"- INSULATION SYSTEM SKETCHES FOR COLD EQUIPMENT 72 APPENDIX "G"- INSULATION SYSTEM SKETCHES FOR HOT EQUIPMENT............................................................................................................ 73 APPENDIX "H"- INSULATION SYSTEM SKETCHES FOR DUCTS OR BREECHING..................................................................................... 74 DUP 0838655 SPECIFICATION NO 8544 VICTORIA Page 1 1.0 GUIDE FOR USING THIS SPECIFICATION 1.1 SPECIFICATION GUIDE 1. Review the drawings or models for the pipe or equipment to be insulated. They will be identified with a double diamond, <><>. 2. The letter/number in the right hand diamond indicates the proper "Insulation Thickness Table". The number in the left hand diamond is the "thickness index" which indicates the insulation thickness in the in the "Insulation Thickness Table". The exception is when a single thickness is indicated such as found on ducts. In this case a cross is shown in the right hand diamond. 3. See the "Table of Contents" in front of the Specific at ion. 4. Note the numbered sections 2 thru 9. 5. Section 2 "Notes and Exceptions" provides data for Site areas or processes wh-ere special insulaton systems may be required. 6. Section 3 "Category" will assist Engineering, Construction and Plant Personnel in verifing that all pipe and equipment which must be insulated is included in the Specification. This Section is also helpfull for maintenance. 7. Section 4 "Material Index" is a list of approved insulation materials. Substitutes are not acceptable. 8. Section 5 "Thickness Index Tables" indicates the insulation material and thickness as shown in the double diamond. Where the insulation thickness index must be determined in the field, take the operating temperature in deg. F and add the number 460, then drop the last digit. Example; 300 deg F + 460 * 76 9. Sections 6,7 and 8 are the "Application Specifications". Review the "Table of Contents" for the correct Specification. 10. Section 9, the "Appendix" includes all sketches for fabrication details and additional supplemental Specifications. DUP 0838656 SPECIFICATION NO 8544 - VICTORIA Page 2 L.2 INSULATION SYMBOLS <60> Thickness Index (Example) The letter between the diamonds signifies special A conditions (Example)<60> <H1> A Stainless Steel Pipe and Equipment S Insulate For Personnel Safety D Dual-Temperature (Double Layer)Defined as a system subject to temperatures above and below freezing. J Duct- Antisweat -Insulation outside the duct. N Noise Reduction Q Fire Res is tant R Removabl e / Reus able In sulation F Factory Pr e-Ins ulated Pipe G Where th e insul at ion c an get wet , heavier and f1 as hi ng is requir ed for equ ipment. DUP 0838657 SPECIFICATION NO 8544 VICTORIA Page 3 2.0 -NOTES AND EXCEPTIONS This Section provides information for areas or pr oc es s e s where special insu lation materials or systems are requi red . DUP 0838658 SPECIFICATION NO 8544 - VICTORIA Page 4 3.0 THERMAL INSULATION SYSTEM- CATEGORY 3u Pont Engineering is responsible to code drawings and aodels . 3.1 CATEGORY NO. 1- SERVICE TEMP. 36 TO 80 F. A. General This category covers requirements for installing thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service36 to 80 F -Freeze protection Temp. F - Temp . C 36 to 80 2 to 27 Notation shown on drawings <50><C2> to <54><C2> 2. Insulation materials Insulation Polyisocyanurate foam- rigid (Code 118.1) 3. Insulation Thickness See Table C2 4. Insulation Jacket Materials Aluminum 5. Application Specification Pipe; see Sections 6.1, 6.3 and 6.6. Equipment; see Sections 7.1, 7.3, 7.5, 7.7 and 7.8. DUP 0838659 SPECIFICATION NO 8544 VICTORIA 3.2 CATEGORY NO. 2- SERVICE TEMP. 80 TO 750 F. Page 5 A . Ge n e r a 1 This category covers requirements for installing .thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service For energy conservation and personnel protection. 80 to 750 F -Steam, process lines and equipment. Temp. F 80 to 750 Notation shown <54> <H2> to Temp. 27 to on drawings <121> <H?> C 399 2. Insulation materials Ins ulation Calcium Silicate (Codes 102.1, 102.2, 102.3) 3. Insulation Thickness See Table H2 4. Insulation Jacket Materials Aluminum 5. Application Specification Pipe; see Sections 6.1, 6.4, 6.6. Equipment; see Sections 7.1, 7.2, 7.3 DUP 0838660 MaBBjwwffHM *m*mta--,-TiSmBiu .a wmnwm wmirawafe mmm-ti f*4 wtfm? tm.rnmw< PTU'Wi SPECIFICATION NO 8544 - VICTORIA 3 CATEGORY NO. 3- PERSONNEL SAFETY Page 6 A. General This category covers requirements for installing . thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service- For personnel pro tection/no energy conservation. Condensate and drain lines. Temp. F __C See below. 2. Insulation nfaterials Insulation Calcium Silicate (Codes 102, 102.1) 140 to 1200 F 60 to 649 C Notation shown on drawings SS <60><H1> to <166><H1> 3. Insulation Thickness See Table HI 4. Insulation Jacket Materials A1uminum 5. Application Specification Pipe; see Sections 6.1, 6.4, 6.6. Equipment; see Sections 7.1, 7.2, 7.3. C. I. To prevent corrosion, guards are preferred instead of insulation for personnel protection where possible. Where protective guards or insulation is required for personnel protection follow these guidelines: Extend the insulation 8 feet above floors, stairs, and regular working or travel platforms. Extend the insulation 3 feet beyond the restrictions of platforms, catwalks, stairs, fixed ladders, or designated travel paths . DUP 0838661 SPECIFICATION NO 8544 - VICTORIA 3.4 CATEGORY NO. 4- SERVICE TEMP. -200 TO +35 F Page 7 A. General This category covers requirements for installing thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service- Cold temperature Brine piping and equipment. Temp. F -200 to + 35 Notation shown on drawings <26><C2> to <49><C2> Temp. -129 C to +2 2. Insulat ion Inater ial S'" Insulation Po1yisocyanurate (Code 118.1) 3. Insulation Thickness See Table C2 4. Insulation Jacket Materials Vapor Barrier + Aluminum 5. Application Specification Pipe; see Sections 6.1, 6.2 and 6.6. Equipment; see Sections 7.1, 7.2, 7.5 and 7.7. DUP 0838662 SPECIFICATION NO 8544 - VICTORIA 3.5 CATEGORY NO 5- DUCTS- IN WET AREAS A. General This category covers requirements Cor installing .thermal insulation systems on ducts. B. Insulation, Thickness, Finish and Application Specifications 1. Service Outdoor and high abuse areas for heating and ventilating ducts. For anti-sweat and warm service. Temp. F Temp. C 36 to 300 - - 2 to 150 Notation shown on drawings JJ <50><+> TO <76><+> 2. Insulation materials Ins ulation 36 to 80 F. 2 Polyisocyanurate 81 to 300 F. 3 Calcium silicate to 27 C. ( Code 118.1) to 150 C. ( Code 102, 102.1) 3 Insulation Thickne s s 1" thick for operating temperatures to 80 deg. F 1 1/2" thick above 80 deg. F or where flanges or stiffeners will not interrupt the finsh. 4. Insulation Jacket Materials Aluminum (Codes 716 series); Specify stucco embossed finish where a wrinkled appearance is undesirable. 5 Application Specifications Ducts; see Sections 8.1, 8.2 and 8.5. Page 8 DUP 0838663 i<T'ii88i'iiiA)ijfiiiiiifiSa aia^lru-ei SPECIFICATION NO 8544 - VICTORIA 6 CATEGORY NO. 6- TRACED PIPE Page 9 A. General This category covers requirements for installing .thermal insulation systems on pipe. B. Insulation, Thickness, Finish and Application Specifications 1. Service Electric or Steam Traced Piping Temp. F Temp. C 81 to 500 27 to 260 Notation shown on drawings <55><H1,H2> to <96><H1,H2> 2. Insulation materials Perlite Silicate (Code 102.2) 3. Insulation Thickness See Table HI, or H2 4 Insulation Jacket Materials A1 um inum 5 Application Specification Pipe; see Sections 6.1, 6.5, 6.6. DUP 0838664 SPECIFICATION NO 8544 - VICTORIA 3. 7 CATEGORY NO 7- DOCTS, PIPE- IN DRY AREAS Page 10 A. General This category covers requirements for installing thermal insulation systems on pipe and ducts. B. Insulation, Thickness, Finish and Application Specifications 1. Service For anti-sweat and hot services; In low abuse areas where the insulation can not get wet. Temp. F Temp. 36 to 375 2 to Notation shown on drawings JJ <50><+> TO ' <84><+> C 190 2. Insulation materials Glass-Fiber (Codes 112, 112.6) 3. Ins ulation Thickness 1" thick for operating tempera tur es to 150 For temperatures above 150 F. see Table C4 Ins ulation Jacket Mate r ial s Fac tory applied FSK finish for sq uare duct Fac tory applied ASJ finish for ro und ducts and pipe 5. Application Specificat ion Pipe and .ducts; see Se ctio ns 8 . 1 AND 8.4 DUP o 09 GO 00 - -T-fg-i -' `A .-i^SLCn SPECIFICATION NO 8544 - VICTORIA 3.8 CATEGORY NO. 9- NOISE PERSONNEL SAFETY Page 11 A. General This category covers requirements for installing thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service Acoustic- No energy conservation Temp. F Temp. C 36 to 1200 2 to Notation shown on drawings NN <50> <H5 > Tff <166><H5'> 649 2. Insulation materials Glass-Fiber (Codes 112.1,A10.2)to 370 F (188 C) NN v <5 0><H5> TO <83><H5> Calcium silicate/glass-fiber composite (Codes 112.1, A10.2, 102, 102.1) above 370 F (188 C). Glass-Fiber to be the out side 1ayer . NN <84><H5> TO <166><H5> 3. Insulation Thickness See Table H5 4. Insulation Jacket Materials Lead laminated Aluminum (Code A30.4) Loaded Mastic (Code A60.5) 5. Application Specification Pipe: see Sections 6.1, 6.2, 6.4 Equipment; see Sections 7.1, 7.2, 7.3 DUP 0838666 SPECIFICATION NO 8544 - VICTORIA 3.9 CATEGORY NO. 10- NOISE - ENERGY CONSERV. Page 12 A. General This category covers requirements for installing .thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service Acoustic- For energy conservation Temp. F 36 to 750 Notation shown on drawings NN <50><H6> TO <121><H6> Temp. C 2 to 399 2. Insulation materials' Glass-Fiber (Codes 112.1.A10.2) to 370 F (188 C) NN <50><H6> TO <83><H6> Calcium Silicate/Glass-Fiber composite (Codes 112.1,A10.2, 102, 102.1) above 370 F (188 C). Glass-Fiber is to be the outside layer. NN <84><H6> TO <121><H6> 3. Insulation Thickness See Table H6 4. Insulation Jacket Materials Lead laminated aluminum (Code A30.4) Loaded mastic (Code A60.5) 5. Application Specification Pipe; see Sections 6.1, 6.2, 6.4 Equipment; see Sections 7.1, 7.2, 7.3 DUP 0838667 SPECIFICATION NO 8544 VICTORIA 3.10 CATEGORY NO. 12- FIRE PROTECTION Page 13 A. General This category covers requirements for installing .thermal insulation systems on pipe and equipment. B. Insulation, Thickness, Finish and Application Specifications 1. Service- Insulation system for fire protection. Temp. F Temp. C 36 to 1200 2 to 649 Notation showen on drawings QQ <50><H1 or H2> to C166XH1 or H2> 2. Insulation materials Insulation Calcium Silicate (Codes 102,102.1) or Perlite Silicate (Code 102.2) 3. Insulation Thickness; See the HI or H2 Tables. Minimum total thickness 4" (double layer) required. Where the insulation thickness tables indicate a thickness greater than 4", use the greater thickness. 4. Insulation Jacket Materials Stainless Steel (Code 753) 5. Application Specification Pipe; see Sections 7.1,7.4 and 7.9. Equipment; see Sections 8.1, 8.5 and 8.7. DUP 0838668 SPECIFICATION NO 8544 - VICTORIA 3.11 CATEGORY NO. 14- FACTORY PRE-INSULATED PIPE Page 14 A. General This category covers requirements for factory pre-insulated . piping, above or below ground. This system may be more economical where lines are greater than 100 ft. long and have few branches. B. Insulation, Thickness, Finish and*Applicat ion Specifications 1. Service- For cold, dual temperature, hot and traced sys tems . Temp. F Temp. C -40 to +1200 -40 to +649 Notation shown on drawings FF <42><+> to <166><+> 2. Insulation materials -40 to 80 F. (-40 to 27 C.) Polyurethane (Code 118) 81 to 1200 F. (28 to 649 C.) Calcium Silicate (Codes 102,102.1) Insulation Thickness See individual specification 4. Insulation Jacket Materials PVC, Polyethylene or FRP with polyurethane insulation. Aluminum, Galvanized Steel, PVC coated Galvanized or stainless steel with calcium silicate insulation. 5. Application Specification Pipe; see Section 6.10 DUP 0838669 SPECIFICATION NO 8544 - VICTORIA Page 15 4.0 MATERIAL INDEX Code Material Designation Brand Name Vendor 102 Calicum Silicate Thermo-12 Kaylo-IOAF Elbow insulation available * Super Caltemp, Type NA * SPRODLE WR1200 * P am s i 1 Manville Corp Owens-Co rning Fiberglas Corp Pabco Insulation Div LouisianaPacific Corp Sproule Mfg. Co. Pamrod, SA 102.1 Calcium silicate inhibited For insulation spec ified by this code number, see code 102 102.2 Perlite silicate Water resistant Sproule WR1200 Sproule Mfg. Co., 112.1 Glass fiber - high temperature pipe covering avail . with ASJ factory applied jacket 850 Snap-On Fiberglass Pipe Insulation Micro-Lok 650 Pipe Insulation Pipe Fiberglas Covering Knauf Pipe Insulation 850 Certain-Teed Corp Manville Corp Owens-Corning Fiberglas Corp Fnauf Fiber Glass Gmb H FFC (Dummy code) Two-piece Fiberglass fitting covers Armaglas-F Fitting Speciality Products covers & Insulation Co. 112.6 Glass fiberboard with factory applied FSK jacket IB300 Certain-Teed Corp. Spin-Glass No. 814 Manville Sales Corp. Rigid Insulation Knauf Fiber Glass Board 3 lb. GmbH Type703 Industrial Owens-Corning Insulation Board Fiberglass Corp. A10.2 Glass Fiberboard Heavy Density (For Acoustics) Spin-Glass No. 817 Manville Sales Corp. IB600 Fiberboard, Type 705 ' Type IB Board Certain-Teed Corp. Owens-Corning Fiberglas Corp. Knauf Fiberglass GmbH 114. 1 Mineral wool inhibited - 900 F Epitherm - 1200 Molded Pipe FBX 1300 Block FBX MF1200 Pipe Insulation Cadafit 1200/S Fibrex, Inc Fibrex, Inc Fibrex, Inc HAMFAB Corp DUP 0838670 SPECIFICATION NO 8544 - VICTORIA Page 1 114.2 118 118.1 501 502.4 508 1212 Blok K-Fac PC RXL 120 High Density Insul. Holmes Insulation U. S. Gypsum Roxul Co Co Mineral wool1200 F - Epitherm- 1200 Molded Pipe FBX 1300 Block FBX MF1200 Pipe Insulation K-Fac PC (block&pipe) Delta 10 Board 1212 blok RXL 120 High Density (block only) Cedarfit 1200 ^Lapinus 1200 Fibrex, Inc Fibrex, Inc Fibrex, Inc U. S. Gypsum Co Rock Wool Mfg Co Holmes Insulations Roxul Co HAMFAB Corp Rockwool Lapinus Polyurethane foam - rigid C-Tek T250 Trymer CPR-190-2 C-Teck Insulation Serv ices Inc. Upjohn Co, CPR Div Polyisocyanurate foam - rigid Type T-250 Rigid Fo am Trymer CPR-9501 C-Tech Insulation Services, Inc. Upjohn Co., CPR Div Asphalt cutback, cork filled Cork-Filled Mastic - 407 FR Lion Nokorode KKote Insul-Mastic , No. 553 - Type D Electro Chemical Engineering and Manufacturing Co Tosco Corp Porter Paint Co Insulating and finishing cement - inhibited Pabcote Louisiana-Pacific Corp, Pabco Insulation Div Heat transfer cement- water soluble Tracit 300 Standard Thermon Zeston Z-10 Chemax Mfg Corp Thermon Mfg co Manville Corp DUP 0838671 510 709 Heat transfer cement nonhardening Fibrated asphalt cutback Note; The (AF) in Tracit-1100 Cont roHeat Grade B Chemax Mfg Corp Controls southeast Inc . Weatherproof Plastic Mastic No. 401 FR ACS Industries, Inc Electro Chemical Engineering and SPECIFICATION NO 8544 VICTORIA Page 17 710 716 716.5 front of the mastic indicates asbestos free. ( AF) Foster C. I. Mastic 60-25 ( AF) Foster C. I. Mastic 60-26 ( AF) Cadamastics 820, 826 Insulkote SG Manufacturing Co H. B. Fuller Co, Assembly Products H. B. Ful1er Co , Assembly Products Epolux Mfg . Co Div Div Manville Corp Insulkote ST Manville Corp Lion Nokorode Seal-Kote Insul-Mastic No. 4010 Seaboard Mastic Tosco Corp Porter Paint Co Seaboard Asphalt Product Co Glass cloth Open weave Glass Cloth, J.P. Stevens Co,Inc S,t~yle 165 9/Geon Glass Cloth, Perma Glas-Mesh Corp. Type 209 10x10 Woven Glass Scrim Burlington Industries Fabric, Resin Inc Treated Style 1659 Luben Scrim Fabric Alpha Associates, Inc Style No. 59 Fiber Glass Scrim Clark Sc'hwebel Fiber Style No. 1659 Glass Corp. Smooth aluminum j acket 0.016" thick with 3-mil poly/ kraft backing Tri-Thermodyne( 3T) Childers Products Co Jacketing Sure-Fit Roll Louisiana-Pacific Jacketing Corp, Pabco Insulation Div Premetco Aluminum Premetco International, Jacket/Poly- Inc Surlyn Moisture Barrier Premetco Aluminum Premetco International, Jacket/3-Mil Inc Polyethylene/Kraft Barrier Aluminum Jacket RPR Products, Inc Aluminum Jacket Quality Service Metals Co Smooth aluminum jacket. Acrylic Coated 0.016" thick with 3-mil poly/ kraft backing Aluminum Jacket Acrylic Finish Sure-Fit Roll Jacketing, Coated Aluminum Jacket, 3-Mil Polyethylene/Kraft Childers Products Co Louisiana-Pacific Corp, Pabco Insulation Div Premetco International, Inc DUP 0838672 SPECIFICATION NO 8544 VICTORIA Page 18 Deep-corrugated aluminum jacket 0.016" thick Cross crimped. (Specify on order) 716.7 Deep-corrugated aluminum jacket. Acrylic coated 0.016" thick with 3-mil poly/ kraft backing Cross crimped. (Specify on order) 716.8 Smooth Aluminum Jacket, "Tadlar" Coated 0.016" thick with 3-mil poly/ kraft backing TED Smooth Aluminum (Dummy Jacket, "Tedlar" Barrier, Acrylic Coated Aluminum Jacket, Poly-Sur1yn Barrier, Acrylic Coated Ac rylic-Co ated Aluminum Jacket Ac rylic-Co ated Aluminum Jacket Premetco International, Inc RPR Products Inc Quality Service Metals Co Deep-Corrugated(3T)Childers Products Co Jacketing Deep-Corrugated Premetco International, Aluminum Jacket, Inc Poly-Surlyn Barrier Deep-Corrugated Premetco International, Aluminum Jacket, Inc " 3-Mil Polyethylene/Kraft Barrier, Epoxy Coated Sure-Fit Roll Lousiana-Pacific Corp, > Jacketing Pabco Insulation Div Aluminum Jacket RPR Products Inc Deep-Corrugated(3T)ChiIders Products Co Aluminum Jacket Acrylic Finish Deep-Corrugated Premetco International, Aluminum Jacket, Inc 3-Mil Polyethylene/Kraft Barrier, Acrylic Coated Deep-Corrugated Premetco International, Aluminum Jacket, Inc Poly-Surlyn Barrier, Acrylic Co ated Acrylic Coated RPR Products Inc Aluminum Jacketing Sure-Fit Roll Lousiana-Pacific Corp Jacketing,Coated Pabco Insulation Div Alumunum Jacket Ultrolon Finish 0.016" thick Aluminum Jacket Tedlar Finish Childers Products Co. Quality Service Metals Co ' Aluminum Jacket Ultrolon Finish Childers Products Co. DUP 0838673 SPECIFICATION NO 8544 - VICTORIA Page 19 Cod e) Coated 0.032" thick with 3-mil poly/ kraft backing 0.032" thick Aluminum Jacket Tedlar Finish Quality Service Metals Co 717.1 45 and 90deg. ell covers, two-piece aluminum die formed Ell-Jac, CE5-6 Moisture Barrier Sure-Fit Elbow Covers A1 um in el s Ell Covers Two-piece Childers Products Co Louisiana-Pacific Corp, Pabco Insulation Div Premetco International, Inc Quality Service Metals Co 717.2 Tee covers, twopiece aluminum - Ell-Jac, CE5-6 Moisture Barrier Sure-Fit Tee Covers Alupinels Childers Products Co Lousiana-Pacific Corp, Pabco Insulation Div Premetco International, Inc 717.3 Valve covers, twopiece aluminum Ell-Jac, CE5-6 Moisture Barrier Sure-Fit Covers Aluminels Childers* Products Co Louisiana-Pacific Corp, Pabco Insulation Div Premetco International, lac 717.4 Flange covers, two piece aluminum Ell-Jac, CE5-6 Moisture Barrier Sure-Fit Covers Aluminels Childers Products Co Louisiana-Pacific Corp, Pabco Insulation Div Premetco International, Inc 717.5 Flat end cap, two piece aluminum Ell-Jac, CE5-6 Moisture Barrier Sure-Fit Covers Aluminels Childers Products Co Louisiana-Pacific Corp, Pabco Insulation Div Premetco International, Inc 717.6 Beveled end cap, one-piece aluminum Ell-Jac, CE5-6 Moisture Barrier Sure-Fit Covers Aluminels Childers Products Co Louisiana-Pacific Corp, Pabco Insulation Div Premetco International, Inc 717.7 45 and 90 deg. aliminum ell covers (gore or miter) Aluminum Jacket, Epoxy/Polyester Finish Aluminum Jacket, Poly-Surlyn Barrier, Acrylic Childers Products Co Premetco International, DUP 0838674 SPECIFICATION NO 8544 VICTORIA Page 20 721 734 Asphalt aluminum coating Insulation mastic 741 Vapor-barrier membrane 743 748 Synthetic organic fiber cloth, open weave PVC one piece fitting (For light duty service only) 749.1 FRP 45, 90 deg. Ell Covers 749.2 FRP Tee Covers 749.3 FRP End caps Coated Aluminum Jacket, 3-Mil Polyethylene/ Kraft Barrier, Acrylic Coated Sure-Fit Elbow Covers Premetco International, Inc Lousiana-Pacific Corp, Pabco Insulation Div Monsey Aluminum Roof Paint Monsey Products Co Vi-Cryl CP-10-F Eco-Mastic 55-50 Foster Aqua-Fas Mastic 38-00 Trowel, 48-00 Spray FnatTer Seal fas GPM 35-00 Foster Sealfas GPM 36-00 Jaxsan 600 Vimasco WC-1FR Vimasco WC-5-FR Mastic Childers Products Co Mon-Eco Industries, Inc H. B. Fuller Co , Assembly Products Div H. B. Fuller Co, Assembly Products Div H. B. Fuller Co , Assembly Products Div Plastic Coatings Corp Vimasco Coatings Corp Vimasco Coatings Corp i Servi-Wrap P-500 Roywrap 550 M W. R. Grace and Co Royston Laboratories, Inc PC Fabric 79 Elasta Fab No.894 Quality Cloth Pittsburgh Corning Corp Vimasco Coatings Corp Quality Service Metals Ceel-Tite 1ight-gauge Permajac SX PVC Zip Jacket (indoor only) CEEL-CO Topline Products Inc. Speed-Line Mfg Co. Chil-Jac Fitting Cover s Perma-Jac H.D. Fitting Covers Childers Products Co Topline Products Co Chil-Jac Fitting Cover s Perma-Jac H.D. Fitting Covers Childers Products Co Topline products Co Chil-Jac Fitting Covers Perma-Jac H.D. Fitting Covers Childers Products Co Topline Products Co DUP 0838675 SPECIFICATION NO 8544 - VICTORIA Page 21 749.4 751.1 752.1 752.3 753 753.1 FRP Flange Cover 8 Chil-Jae Flange Covers Perma-Jac Flange Childers Products Co Topline Products Co Aluminum Jacket 32 mil thick Specify Acrylic Coated Tri-Thermodyne(3T) Jacketing 32 mil .032 Sure-Fit Roll Jacketing 32 Mil Aluminum 32 Mil Premetco Aluminum Jacket/ 3-Mil Poly/Kraft or Poly-Surlyn Childers Products Co Louisiana-Pacific Corp. Pabco Insulation Div. RPR Products, Inc Premetco International, Inc Aluminum Jacket 24 mil thick Specify Acrylic Coated Tri-Thermodyne(3T) Jacketing 24 mil .024 Sure-Fit Roll Jacketing 24 Mil Aluminum 24 Mil premetco Aluminum Jacket/ 3-Mil Poly/Kraft or Poly-Surlyn Childers Products Co Louisiana-Pacific Corp. Pabco Insulation Div. RPR Products, Inc Premetco International, Inc t Deep-Corrugated 24 Mil Acrylic Co ated Specify cross krimp on order 24 Mil DeepCorrugated Acrylic Coated with 3 mil Poly/ Kraft or Poly/ Surlyn 24 Mil Deep- Corrugated (3T) Acrylic Coated Acrylic Coated Aluminum Jacket 24 Mil with 3 Mil Poly/Kraft Deep-Corrugated .024 Sure-Fit Roll Jacketing Acrylic Coated Premetco International Childers Products Co RPR Products Inc Louisiana-Pacific Pabco Div Smooth stainless Steel 0.010"thick jacketing (Specify Type 304 or 316 for fire protection and 316 only for corrosion protect.) 10 Mil Smooth Stainless Steel Jacket with 3 mil poly/kraft barrier Childers Products Co Premetco international, Inc RPR Products, Inc Quality Service Metals Co Louisiana-Pacific Corp. Pabco Insulation Div. 45 and 90 deg. ell Stainless steel Ell-Jac, Stainless Childers Products Co Steel Stainless Steel RPR Products, Inc O c u o 00 Co oo 0) "4 SPECIFICATION NO 8544 VICTORIA Page 753 .2 753.3 753.4 A30.4 A60.5 802.1 810 813 817 826 Ell Tee covers, twopiece stainless steel Ell-Jac, Stainless Steel Stainless Steel Tee Covers Childers Products RPR Products, Inc Co Beveled end cap Stainless Steel Ell-Jac, Stainless Steel Stainless Steel Beveled End Cap Childers Products RPR Products, Inc Co Deep-corrugated stainless steel jacket 0.0l0"thick 10 Mil Deep-Corr. Childers Products Co Type-316 Stainless Steel Jacket Lead Sheeting Aluminum jacket Specify 1 lb. or 2 lb . / s q . ft. Lead Muff1-Jac Super Lead-lined Childers Products Co. Premetco International, Inc . Loaded mastic Apply at 0.14" thickness Lagging adhesive Muf f1-Lag Childers Products Co., Inc . Sodium Silicate, Technical Grade Sodium Silicate, N Brand F Du Pont Co, Chemicals and Pigments Dept PQ Corp Water-resistant adhesive Note 1. Nonflammable in wet state Foster Stic-Safe 85-15 (Brush, Spray Grade) Adhesive No. 33 Spray Grade Chil-Stix Clear CP-85 (Trowel) Chil-Spray NF CP-89 (Spray)(1) H. B. Fuller Co. Assembly Products Div 3 M Co Childers Products Co Caulking compound Silastic 732 RTV Silicone Sealant SCS-1202, White Silicone Sealant Dow Corning Corp. General Electric Co General Electric Co Al uminum Chem-Calk 1200-75 No. 1020 Woodmont Products Anchor Adhesive Tuff-Bond Quik-Set Goodloe E. Moore Co. Insulation Adhesive Tuff-Bond No. 9 Sytrofoam Brand Goodloe E. Moore Co. Dow Chemical SPECIFICATION NO 8544 VICTORIA Page 23 901 921 926 927 964. 1 964.2 971.1 979 980 ' 987 992 Mastic No. 11 Rain Shields (PVC) Rainshield Topline Products, Inc Stainless steel wire (18 gage) Stainless Steel Wire Applicator or Distributor Stainless steel bands and seals (3/8" x .015") Stainless Steel Bands and Seals Applicator or Distributor Stainless steel bands and seals (3/4" x .015") Stainless Steel Bands and Seals Applicator or Distributor Spindle Anchors (metal plate) Spindle Anchors Metal Plate Spindle Anchors Metal Plate Goodloe E. Moore Co Miracle Adhesives Corp Spindle Anchors (nylon plate) Spindle Anchors Nylon Plate Goodloe E. Moore Co Sheet-metal screws (stainless steel) Sheet-Metal Screws (Type AB,ANSI) Sheet-Metal Screws (Type AB,ANSI) K. G. Lilly Fasteners, Inc Premetco International, Inc Insulation Pins (weldable 10 ga.) Specify length Insulation Insulation Insulation Insulation Pins Pins Pins Pins AGM industries, Inc H. A. Jones Co, Inc Nelson Div TRW, Inc Rilco Manufacturing Co Division of Sadler Industrial Services 'Inc All weather springs breather All Weather Breather Springs All Weather Breather Springs Techalloy All Weather Breather Techalloy All Weather Breather Springs Ins ul-Mate Childers Products Co A. J. Gerrard and Co Techalloy Co, Inc, De-Tech Instrument Techalloy Co, Inc, De-Tech Instrument Div RPR Products, Inc Masking Tape Scotchbrand No . 280 Masking Tape 3M Co Listing tape (glass cloth) Specify 2" wide x min. thk. 0.060" Thermoglass Tape, 9731 Finish Thermoglass Tape, 9731 Finish Thermoglass Tape, Alpha Associates, Inc Amatex Corp Claremont Co, Inc DUP 0838678 SPECIFICATION NO, 8 544 VICTORIA Page 24 9731 Finish 997 S-clips (stainless steel) Stainless Steel Band (see Code 927) Applicator or Distributor 998 Nylon Fasteners Prefast Fasteners Premetco International, Inc 999 Pressure Sensitive Tapes 1520 CW Foil 1540 CW ASJ Mactac ASJ 6100 IA-8000 2 Mil Foil Perms Tape ASJ Std. 105-7 2 Mil Foil 120-6 Fastape ASJ 0835 Fastape 0805 2-Mil Foil Venture Tape Corp. Morgan Adhesives Co. Compac Corp. Fasson Industrial Div. DEF (dummy c ode) Preinsulated Unitherm Dekatrace t ubing(plain, Thermotube elec . or steam traced) 1/8 to 3/4" t ubing Order with transition fitting covers Samuel .Moore and Co. Thermon Manufacturing Co 1 DUP 0838679 SPECIFICATION NO 8544 - VICTORIA Page 25 5.0 THICKNESS INDEX 5.1 TABLE C 2 THICKNESS INDEX TABLE C2 Temperature range: MINUS 200 TO 80 F (-129 TO 27 C) Use for: Cold, dual temperature, electric or steam traced systems Insulation: Polyisocyanurate, Code 118.1 36 to 80 F. Thicknesses shown are calculated to provide the economic insulation thickness and a surface temperature which does not exceed 140 deg. F NOMINAL PIPE DIAMETER Thick .5 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Equip 1 1.5 54 54 54 54. 54 54 -54 54 54 54 54 54 54 54 54 54 EXAMPLE: 12" pipe, "Thickness Index" <53><C2> 1. Look under column for 12" pipe 2. The number "53" is not listed: go to the next higher number Listed - in this case "54" and the thickness is 1 1/2". 35 F and Below The thicknesses at the exterior condition is 95 listed below are calculated to prevent condensation surface of the insulation when the ambient temperature deg. F with a 7 deg. F dew point depression. Thick NOMINAL PIPE DIAMETER Inch. .5 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Equip 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 44 46 40 40 31 36 21 31 16 48 48 48 49 49 49 44 44 46 48 48 48 48 48 .48 48 4H 49 49 36 40 42 42 44 44 46 ' 46 46 46 46 46 . 48 33 36 40 40 40 40 42 42 44 44 44 44 44 21 26 31 36 36 36 40 40 40 40 41 42 42 16 21 26 31 33 34 36 36 37 38 39 40 40 16 16 11 26 31 31 31 36 36 36 36- 36 16 21 26 26 26 31 31 31 31 32 16 21 21 21 21 21 24 28 31 16 16 16 18 19 20 21 26 16 16 16 16 21 16 49 48 45 44 40 38 34 33 28 23 20 EXAMPLE: 8" PIPE, "THICKNESS INDEX" 1. Look under col umn for 8" pipe. 2. The number "42 It is not listed: listed - in this ease "40 " and <42><C2> - go to next lowe r the thickness is - index number 3" 'i DUP 0838680 f ' iiifcUh ?gs iiajtiST- aiv^att.itat-1.'- SPECIFICATION NO 8544 - VICTORIA Page 26 5.2 TABLE C4 THICKNESS INDEX TABLE C4 Temperature r ange: 36 to 375 F (2 to 1 90 C) Use for: An ti-swea t a nd hot se rvic es ; in low ab use areaLS where th e insul at ion cannot get wet Insulat ion: G1as s- fib er (Codes 112 ,112 .6) Thicknesses shovn are calculat ed t o pr ov ide the economic insulat ion thickness a nd a surface temper atur e wh ich d oes not exce ed 140 F. NOMINAL PIPE DIAMETER Thic k. Flat Inch .5 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Surf . 1 SL 84 84 1.5 SL 2 SL 84 84 82 81 79 78^_' ,77 76 75 74 73 72 71 61 84 84 84 84 84 84 84 83 82 82 81 71 84 84 84 84 81 2.5 SL 84 "SL" denot es sing le 1ayer. EXAMPLE: 12" p ipe , "Thic kne ss Ind ex" <80> <C4> 1. Look under column for 12 " pipe 2. The number "80" is no t 1 isted: Go to n ext h ighe r number . 3. In this cas e "84". Us e 1 1/2" thic knes s . DUP 0838681 SPECIFICATION NO 8544 VICTORIA Page 27 5.3 TABLE HI THICKNESS INDEX TABLE HI Temperature Range: 140 to 1200 F (60 to 649 C) Use for: Personnel Protection Thicknesses shown are calculated to provide the economic insulation thickness and a surface temperature which does not to exceed 140 F. TEMPERATURE RANGE: 140 to 1200 F Insulation: CALCIUM SILICATE (CODES 102, 102.1) NOMINAL PIPE DIAMETER Thick Flat Inch .5 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Sur 1 96 95 89 88 84 83 78 1 . 5 121 116 108 106 10k '99 97 94 94 93 90 88 88 88 87 91 2 146 138 138 124 118 113 109 107 106 104 101 100 99 98 98 102 2 .5 166 158 155 141 133 129 122 121 118 116 112 111 110 108 108 U2 3 166 166 158 147 144 135 134 130 128 123 122 121 120 118 122 3. 5 4 4. 5 5 166 166 157 149 146 141 139 134 133 132 130 127 132 166 163 158 150 150 143 142 141 141 136 142 166 166 161 160 153 152 150 150 146 150 166 166 166 166 166 166 166 166 S Example : 12" pipe , th ickniess index <70> <H1> 1. Look under col umn for 12" pipe . 2. The number 70 is not 1 isted . 3. Go t o next higher numb er 1 isted - Inl th:Ls c ase 93. 4. Use 1 1/2 " th ickness. D C TJ O 0to0 00 o> M00 SPECIFICATION NO 8544 - VICTORIA Page 28 .4 TABLE H2 THICKNESS INDEX TABLE H2 Temperature range: 81 TO 750 F (27 to 399 C) Use for: Energy conservation of steam energy Insulation: Calcium Silicate (Codes 102.1,102.2) Thicknesses shown are calculated to provide the economic insulation thickness and a surface temperature which does not exceed 140 F. NOMINAL PIPE DIAMETER Th ick. FI Inch. .5 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Su 1.5 SL 93 89 77 73 73 73 71 68 2 SL 104 98 98 80 76 74 73 70 2.5 SL 121 109 108 101 93 86- 80 80 78 73 73 73 72 70 70 3 SL 121 115 109 103 100 95 90 90 90 87 87 87 86 85 70 3.5 DL 4 DL 4. 5 DL 121 116 110 107 105 103 101 100 98 96 95 94 93 121 121 118 115 113 no 104 100 100 98 98 97 121 121 121 116 114 112 no 108 107 105 85 93 97 5 DL 121 121 121 117 113 111 109 105 5.5 DL 121 121 121 115 109 6 DL 121 115 6.5 DL 121 "SL" denotes single layer. "DL" denotes double layer. EXAMPLE: 12" pipe, "Thickness Index" <93><H2> 1. Look under column for 12" pipe. 2. The number "93" is not listed: Go to next higher 3. In this case "100". Use 3 1/2" thickness. number. DUP o 00 03 00 CD 00 SPECIFICATION NO 8544 - VICTORIA 5.5 TABLE H5 Page 2 9 THICKNESS INDEX TABLE H5 Temperature Range: 41 to 1200 F (2 to 649 C) Use for: Thermal/Acoustic without energy conservation Thicknesses shown are calculated to provide a surface temperature which does not exceed 140 F. Insulation Thick.(In .) Mat * 1 codes 112.1 NOMINAL PIPE DIAMETER or 102.1 A10.2 .5 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Eq . 0 + 2 83 83 83 83 83 " 83 83 83 83 83 83 83 83 83 83 83 1 + 2 165 165 158 147 144 135 1.5 +2 165 165 157 149 146 141 139 134 133 132 130 127 132 2 +2 165 163 158 150 150 143 142 141 141 136 142 2.5 +2 165 165 161 160 153 152 150 150 146 150 3 +2 165 165 165 165 165 165 165 165 N EXAMPLE: 12" pipe -" Thickness index" <132> <H5 > 1. Look under column for 12" pipe. 2. The number "132" is not listed. 3. Go to next higher number which is "139". 4. Use 1.5" of Code 102.1 plus 2" of code 112.1 or A10.2 which gives a total thickness of 3.5". SPECIFICATION NO 8544 - VICTORIA 5.6 TABLE H6 Page 30 THICKNESS INDEX TABLE H6 Temperature Range: 41 to 750 F ( 2 to 399 C ) Use for: Thermal/Acoustic with energy conservation Thicknesses shown are calculated to provide a surface temperature which does not exceed 140 F. Ins ulat ion Thick.(In .) Mat'1 codes 112.1 or 102.1 A10.2 .5 NOMINAL PIPE DIAMETER 1 1.5 2 3 4 6 8 10 12 14 16 18 20 24 Eq . 0 +2 104 98 98* 80 76 73 1 1.5 2 +2 121 121 115 109 103 100 95 90 90 90 87 87 87 86 85 70 + 2 121 116 110 107 105 103 101 100 98 96 95 94 93 85 + 2 121 121 118 115 113 110 104 100 100 98 98 97 `93 2.5 + 2 121 121 121 116 114 112 110 108 107 105 97 3 +2 121 121 121 117 113 111 109 105 3.5 +2 121 121 121 115 109 4 4.5 +2 +2 121 115 121 N EXAMPLE: 12" pipe - "Thickness Index:" <102><H6> 1. Look under column for 12" pipe 2. The number "102" is not listed 3. Go to next higher number which is "104". 4. Use 2" of Code 102.1 plus 2" of code 112.1 or A10.2 which gives a total thickness of 4". DUP 0838685 -gaseaL SPECIFICATION NO 8544 - VICTORIA Page 31 6.0 PIPE INSULATION 6.1 GENERAL CONDITIONS 6.1.1 Keep Che insulation dry at all times during storage and installation. No wet insulation shall be installed. If the insulation becomes wet during or after installation, it shall be removed and replaced with new dry insulation. The insulation may be protected with plastic film, but must be vented to prevent sweating. 6.1.2 Finish on pipe, fittings, flanges, valves, metal. The only exceptions to this requirement surfaces and removable insulation described in the this specification. etc., to be are irregular Appendix of 6.1.3 Provide the following corrosion protection to insulated pipe and tubing. 6.1.3.1 All carbon steel-pipe shall be painted per the paint specification. 6.1.3.2 Stainless steel pipe and tubing which is not painted' shall be protected with mastic at 35 deg. F and below and above 35 deg. F coat the pipe or tubing with sodium silicate per this * specific at ion . 6.1.3.3 Do not apply sodium silicate to the pipe where it will not be insulated. 6.1.3.4 When coateing the stainless steel surface to be insulated with sodium silicate (Code 802.1) add red food coloring at the rate of 1 ounce per gallon. Use a minimum of 1 gallon per 100 sf. Let coating dry before applying insulation. Do not apply sodium silicate to items that cannot be covered by" insulation on the same day. 6.1.4 Leave flanged joints un-insulated until connecting pipe and equipment has been hydrostatically tested by Du Pont, and released to the contractor for completion of insulation. 6.1.5 Steam tracer jumpers will be installed outside of the insulation at all flanged joints. 6.1.5.1 Cover steam tracer jumpers with 2" wide listing tape,(Code 992), spiral wrapped with 50Z overlap. Finish listing tape with a coat of insulation mastic, (Code 734). 6.1.6 Instrument tubing can be insulated as indicated in the previous paragraph. Where long tubing lines or severe weather conditions are anticipated, it is recommended to use the preinsulated tubing (Code DEF). 6.1.7 All fittings (flanges, valves, nozzles, drains, etc) are to be insulated (unless specifically excluded) with the same DUP 0838686 SPECIFICATION NO 8544 - VICTORIA Page 32 thickness as the adjacent piping. On screwed fittings, use insulation with same O.D. as adjacent pipe insulation. 6.1.8 At flanged joints, stop the insulation 1 bolt length plus 1" from the back of the flange. Do not bevel insulation. 6.1.9 See sketches in the Appendix for methods of installing and finishing removable insulation on hot and cold systems. 6.1.10 On piping where the insulation can get wet, install rain shields (Code 901) secured with nylon fasteners (Code 998) per Appendix B on horizontal lines where pipe hanger rods or pipe clamps penetrate top of insulation. Support all new lines outside the insulation jacket where possible with a 180 degree, 10 gage galvanized steel saddle (length to be 1.5 times the O.D. of the insulation). 6.1.11 Where protective guards or insulation is required for personnel protection follow these guide lines: 6.1.11.1 Guards are preferred instead of insulation for personnel protection where possible. 6.1.11.2 8 feet above floors, stairs, and regular working or travel platforms. 6.1.11 3 3 feet beyond the restrictions of plat forms, catwalks ', stairs, fixed ladders, or designated travel paths. DUP 0838687 SPECIFICATION NO 8544 - VICTORIA Page 33 6.2 APPLICATION SPECIFICATION FOR THICKNESS INDICES <49> AND BELOW.(35 DEG.F & BELOW) TABLE C2 6.2.1 Insulate with polyisocyanurate, (Code 118.1). 6.2.1.1 Use plain joints for thickness indices <47> through <49>, 10 through 35 F. 6.2.1.2 Use offset butt and longitudinal joints for thickness index <46>, 0 F and below. If offset joints are not used, install double-layer insulation. 6.2.2 Stagger joints. 6.2.3 Install insulation in a full bedding coat of fibrated asphalt cutback (Code 709). Coat all contact surfaces of the insulation with the same material. 6.2.4 All cuts for protrusions such as nozzles, hangers, brackets, etc, 'shall be^tightly fitted. No gaps are permitted around these cutouts. Seal all cutouts with fibrated asphalt cutback (Code 709) at time of application. 6.2.5 Secure insulation through steel wire (Code 921), applied 9" centers. Above 12" O.D. use seals (Code 926). 12 O.D. with 18 gage stainless over masking tape (Code 987), on 3/8" stainless steel bands and f 6.2.6 Where insulation terminates at flanges, flanged fittings, etc, cover the end of the insulation and a 2" minimum of the insulation and the adjacent metal with fibrated asphalt cutback (Code 709), reinforced with organic fiber cloth, open weave (Code 743) . 6.2.7 Insulate all metal in contact with the pipe and that which protrudes through the insulation with the same thickness as the pipe insulation. Cover the protrusions for a minimum of 12" from the insulation surface on the pipe. 6.2.8 Apply vapor barrier membrane (Code 741), to the pipe insulation. Overlap adjacent sheets a minimum of 2" at all joints. Vapor barrier membrane to be applied smooth, tight, adhered to the insulation wrinkle-free, and sealed-off to all penetrations. 6.2.9 When fittings are fabricated from pipe insulation, use thickness equal to that of the pipe insulation. Install fitting insulation in a full bedding coat of fibrated asphalt cutback (Code 709). Coat all butt joints of the insulation with the same material. DUP 6.2.10 Finish fittings with reinforced mastic. Apply a tack coat of fibrated asphalt cutback (Code 709) and imbed organic fiber cloth, open weave (Code 743). Overlap adjacent reinforcing material a minimum of 2". Also overlap vapor barrier membrane o> 00 SPECIFICATION NO 8544 -VICTORIA Page 34 (Code 741), a minimum of 2". Apply a second coat as soon as the first coat becomes tack-free. Both coats must be applied the same day. (First coat 25 S.F. per gallon, second coat 17 S.F. per gallon). Approximately 1/10" dry film thickness. DUP 0838689 -atmaag.. ; ags.attMrlim w: SPECIFICATION NO 8544 - VICTORIA Page 35 6.3 APPLICATION SPECIFICATION FOR THICKNESS INDICES <50> THRU <54> (35 THRU 80 F) TABLES HI, C2, H5, H6 - 6.3.1 Insulate with polyisocyanurate (Code 118.1). 6.3.2 For acoustical applications insulate with glass-fiber (Code 112.1). Secure the insulation in the same manner as indicated in this specification. 6.3.3 If cracks or imperfections cannot be satisfactorily closed, replaced the affected section of insulation. 6.3.4 Offset (ship-lap) insulation is preferred. Where plain joint insulation is used, coat (seal) all butt surfaces of insulation with fibrated asphalt cutback (Code 709). Coat all irregular metal projections a minimum of 6" from the pipe insulation surface with cork filled mastic (Code 501). 6.3.5 Stagger joints. 6.3.6 Secure insulation thru 12" O.D. with 1" masking tape (Code 987) on 9" centers. Above 12" O.D. use 3/8" x .015 stainless steel bands and seals (Code 926). 6.3.7 Do not bevel the insulation where it is terminated at t flanges, valves, etc. 6.3.8 Commercially available fitting covers are preferred. 6.3.9 When fitting covers are fabricated from pipe insulation, use thickness equal to that of the pipe insulation. 6.3.10 All cuts for protrusions such as hangers, nozzles, nipples, etc, must be tightly fitted. No gaps are permitted around these cutouts. DUP 0838690 SPECIFICATION NO 8544 - VICTORIA Page 36 6.4 APPLICATION SPECIFICATION FOR THICKNESS INDICES ABOVE <55> (81 TO 1200 F) TABLES HI, H2, H5, H6 - . ) .6.4.1 Insulate with calcium silicate (Code 102.1) or (Code 102 2 6.4.2 For acoustical applications where the temperatures require the calcium silicate/glass-fiber composite system, secure the calcium silicate as indicated in this specification. 6.4.3 Stagger joints. 6.4.4 Secure with 18 gage stainless steel wire (Code 921), 3 per section through 20" O.D. Above 20" O.D. use 3/8" x .015 stainless steel bands and seals (Code 926). 6.4.5 Close cracks or imperfections by either tamping, or filling with insulating and finishing cement, inhibited (Code 502.4) . 6.4.6 Commercially available fitting covers are required. Molded calcium silicate (Code 102.1), (Code 102.2) or Routed Mineral wool (Code 114.1), (Code 114.2). 6.4.7 When fittings are fabricated from pipe insulation, use. insulation thickness equal to that of the pipe insulation. 6.4.8 Do not bevel the terminated insulation at flanges, valves, etc . 6.4.9 All cuts for protrusions such as hangers, nozzles, nipples, etc, must be tightly fitted. No gaps are permitted. DUP 0838691 SPECIFICATION NO 85'44 VICTORIA Page 37 6.5 APPLICATION SPECIFICATION FOR TRACED PIPE FOR THICKNESS INDICES 55 THROUGH 96 (81 THRU 500 DEG. F) TABLES HI, H2 - --6.5.1 Insulate with perlite silicate, (Code 102.2) 6.5.2 Use insulation with I.D. for next larger size pipe which will accommodate, but not touch, tracer(s). 6.5.3 Do not "route-out" insulation or allow tracer to embed in insulation . 6.5.4 Provide nominal 1" wide x 9" long spacers on 18" centers between pipe O.D. and insulation I.D. 6.5.5 Spacer to be same material as pipe insulation. 6.5.6 Thickness of spacer must be sufficient to provide snug fit and firm support for pipe insulation. 6.5.7 Center every othe^ spacer at butt joint of pipe insulation. 6.5.8 Stagger joints. 6.5.9 Install draft stops on vertical lines. Use heat transfer J cement-nonsetting (Code 510) through 425 deg. F and water soluable cement (Code 508) above 425 deg. F on nominal 4 ft. centers. Width of stop to be a minimum of 1" wide and thick enough to completely fill the space between the pipe and insulation. Locate stops at top and bottom of vertical section and at terminations above and below flanged or screwed connec tions. 6.5.10 If cracks or imperfections cannot be satisfactorily closed, replace the affected section of insulation. 6.5.11 Secure insulation wire, (Code 921), over centers. Above 12" O.D. and seals, (Code 926). thru 12" O.D. with stainless steel 1" masking tape, (Code 987), 9" on use 3/8" x .015 stainless steel bands 6.5.12 Do not bevel terminated insulation at flanges, valves, etc . 6.5.13 Commercially available fittings are preferred. 6.5.14 When fittings are fabricated from pipe insulation, use thickness equal to that of the pipe insulation. 6.5.15 All cuts for protrusions such as hangers, nozzles, nipples, etc., must be tightly fitted. No gaps are permitted around these cutout?. 6.5.16 See sketches in Appendix for installation details. DUP 0838692 SPECIFICATION NO 8544 - VICTORIA Page 38 6.6 FINISH - . 1 u s e .016" smooth ac ryl ic coat .5) . aluminum jacketing (Code . 2 L ap jacket a min imum of 2" circumferentially g itud in ally. Machine cut and roll to provide a tight tall in a wat:ershed fa shion wit laps on horizontal ween th e two and thr ee o' clock ppoosition. and fit. pipe 6.6.3 On electrically traced lines, secure jacket with 3/8" x .015" thick stainless steel bands, (Code 926), on 9" centers with a band over each circumferential lap, or secure jacket with nylon fasteners, (Code 998), on 4" centers thru 6 1/2" O.D. and on 6" centers above 6 1/2" O.D. Do not use metal screws on jacket or fitting covers. 6.6.4 Jackets installed on lines which have a vapor barrier membr ane (Code '741) or^re in forced asphalt cutback (Code 709). Inst a lied over the insulation, must be secured with 3/8" x .015" thick stainless steel bands and seals (Code 926) on centers. Do not u se screws for covering or fitting finish. Do not let j acke ting interfere with vapor barrier installation. 6.6.5 Band ing is the required me thod all t ites . Prov ide 3/8" x 0. 015" ( Code 926) on 9" c ente rs with a b and lap . to secure a 11 j acket ing on thick s tainle ss stee 1 bands over e.ach c ire urnfe rent ial 6.6.5. 1 An er ing al tern ativ e for ho t Dept . c oncurranc e pipi is ng, whiere using 3/8 II permitte long , d No wi . th 7 ess steel shee t metal 8 crews ( Code 97 1. 1) or nyl on ner s ( Code 998) on 4" c en ters through 6-1 " O.D., and 6" 6-1/2 " O.D. 6.6.6 Use aluminum fi tting cov er a (Code 717 .1) , ( Code 717. 2), (Code 717. 3), (Code 717.4) , ( Code 71 7.5) or ( Code 717.6) on all fittings to the largest commercially available size. Otherwise use fabricated metal covers (Code 717.7) or purchased FRP covers (Code 749.1). The FRP covers are more economical to install and are preferred for water resistance he al mum gore or miter covers. FRP flange covers (Code 749.4) are t ferr ed ov er aluminum flange covers (Code 717.4). Pont 326Y line "Imron" coating. (Code 749.2) (Code 749.3) and Specify FRP finish to be white. s sp ecifie <*. yl ic or a Du FRP fitting covers ( Code 749. 1) (Code 749.4) is alsc acc eptabl e . 6.6.6.2 In highly corrosive areas where "Tedlar" coi ted alum in um (Code 716.8) is specified, only FRP fitting covers ( Cod e 749. 1) (Code 749.2) (Code 749.3) and (Code 749.4) are acc eptabl e. Specify FRP finish to be white. DUP 0838693 1* "iHIl'iiM aBBIi'. ft -safetas- Jget*:t*ar'^iaMvaeJ* " SPECIFICATION NO 8544 - VICTORIA Page 39 6.6.7 On irregular surfaces use Che following finish. 6.6.7.1 Where insulation can get wet or in high mechanical abuse areas, use a reinforced polyester or epoxy finish system. See Engineering Std. SN221P or the attached Epoxy Resin Specification. 6.6.7.2 On hot services where the insulation cannot get wet and in low mechanical abuse areas, use a reinforced mastic system. Apply a tack coat of insulation mastic (Code 734), and imbed open weave cloth (Code 743). Overlap adjacent reinforcing material a minimum of 2". Apply a second coat as soon as the first coat becomes tack-free. Both coats must be applied the same day. Total coverage is 10 to 15 sq. ft. per gal. 6.6.8 Install aluminum beveled end insulation terminations above 35 insulation. caps (Code 717.6) at all F <50>. Do not bevel the 6.6.9 Seal all penetratio-irS' and possible points of moisture entry with a 3/8" b~ad (minimum) of caulking compound, (Code 813). This is to be done at the time of metal application. Do not feather edges. Apply on clean, dry surface at a temperature recommended by the manufacturer. 6.6.10 Finish for removable insulation on cold services will be a tack coat of fibrated asphalt cutback (Code 709) reinforced with organic fiber cloth, open-weave (Code 743). Embed the reinforcing in the wet tack coat. Lap adjacent pieces of reinforcing a minimum of 2 inches, and eliminate all wrinkles and protruding edges. Apply a second coat as soon as first coat becomes tack-free. Both coats must be applied the same day. (First coat 25 S.F. per gallon, second 17 S.F. per gal). Apply a final finish coat of asphalt aluminum coating (Code 721) after the (Code 709) is dry. 6.6.11 For acoustical applications, finish the insulation with lead laminated aluminum (Code A30.4). 6.6.11.1 the lead laminated aluminum (Code A3 0.4) can purchased with an acrylic or tedlar finish. be 6.6.11.2 The standard lead laminated aluminum has a 1 lb/sq.ft lead barrior. For severe noise conditions the jacket can be purchased with a 2 lb/sq.ft lead lamination. 6.6.11.3 Secure this jacketing with bands as indicated in this specification. 6.6.11.4 Fittings and irregular shapes shall be finished with loaded mastic (Code A60.5) and reinforcing open weave glass cloth (Code 710). Embed cloth into mastic which shall be a minimum thickness of 0.14". O UP 0838694 SPECIFICATION NO 8544 VICTORIA Page 4 6.7 FIRE RESISTANT FINISH (WHEN SUPPLEMENTARY CODE LETTER Q IS USED) - 6.7.1 Use .010 smooth stainless steel jacketing (Code 753). 6.7.2 Lap jacket a minimum of 2" circumferentially longitudinally. Machine cut and roll to provide a tight Install in a watershed fashion with laps on horizontal between the two and three o'clock position. and fit. pipe 6.7.3 Banding is the required method all sites. Provide 3/8" x 0.015" (Code 926) on 9" centers with a band lap. to secure all jacketing on thick stainless steel bands over each circumferential 6.7.3.1 On electrically traced lines, or lines vapor barrier membrane (Code 741) or reinforced (Code 709), installed over insulation, screws are to secure the jacket or fitting covers. which have a asplalt cutback never permitted 6.7.3.2 An alternative for hot piping, whwre permitted with Engineering Dept. concurrence, is using 3/8" long, No.7 stainless steel sheet metal screws (Code 971.1) on 4" centers through 6-1/2" O.D., and 6" above 6-1/2" O.D. 6.7.4 Use preformed stainless steel fitting covers (Code (Code 753.2) to the largest commercially available otherwise use fabricated metal covers. Use stainless finish on all fittings and irregular surfaces. 753.1) size, steel 1 6.7.5 Install all insulation not bevel the fittings. stainless steel beveled end caps (Code 753.3), at terminations above 35 F,thickness indice <49>. Do insulation. Install end caps at all flanged 6.7.6 Seal all penetrations and possible points of moisture entry with a 3/8" bead (minimum) of caulking compound, (Code 813). This is to be done at the time of metal application. Do not feather edges. Apply on clean, dry surface at a temperature recommended by the manufacturer. 6.7.7 Finish for removable insulation on cold services will be a tack coat of fibrated asphalt cutback, (Code 709), reinforced with organic fiber cloth, open-weave, (Code 743). Embed the reinforcing in the wet tack coat. Lap adjacent pieces of reinforcing a minimum of 2 inches, and eliminate all wrinkles and protruding edges. Apply a second coat as soon as first coat becomes tack-free. Both coats must be applied the same day. (First coat 25 S.F. per gallon, second 17 S.F. per gal). Cover reinforced mastic system with stainless steel (Code 753). DUP 0838695 SPECIFICATION NO 8544 - VICTORIA Page 41 6.8 FACTORY PRE-INSULATED PIPE (WHEN SUPPLEMENTARY CODE LETTER F IS USED) - 6.8.1 Factory pre-inaulated pipeis available for above ground and underground systems. 6.8.2 When placing order, include the following information. 6.8.2.1 Minimum operating temperature of pipe. 6.8.2.2 Maximum normal operating temperature of pipe. 6.8.2.3 Complete DuPont pipe specifications for procurement of pipe including length desired. Vendor can handle up to 40 ft. lengths . . . .6 8 2 4 Maximum and minimum ambient air temperature. . . .6 8 2 5 Average-wind velqe-iTty. . . .6 8 2 6 Maximum external surface temperature of insulation is not to exceed 140 F. 6.8.2.7 Maximum allowable heat gain/loss. 6.8.2.8 Thickness of insulation on cold systems is sufficient to prevent surface condensation when temperature is 95 F. with a 7 Deg. dewpoint depression. 6.8.2.9 End of pipe is to extend 6" beyond end of insulation. 6.8.2.10 Copy of necessary arrangement drawings clearly marked to show scope of work to be pre-insulated. 6.8.2.11 Request submission of approvial drawings for review prior to release of fabrication. 6.8.2.12 For hot systems, protect exposed ends of insulation to prevent water entry and exposure to sunlight. 6.8.2.13 For cold systems, seal exposed ends of insulation heat shrunk sleeve to provide permanent vapor barrier. 6.8.2.14 The jacket material for cold and hot systems must be selected on environmental conditions. 6.8.2.14.1 For hot systems (81 to 1200 F.) the be calcium silicate (Code 102) or (Code 102.1) 22 gauge aluminum, 24 gauge' galvanized steel galvanized steel or 26 gauge stainless steel insulation shall with jacketing of and PVC coated 6.8.2.14.2 For cold and warm temperatures (-40 to +80 F.) the insulation shall be polyurethane (Code 118) with jacketing of PVC, polyethylene or FRP. DUP 0838696 SPECIFICATION NO 8544 VICTORIA Page 42 6.8.2.15 Caution must be considered when welding "sect" to stainless steel pipe. Sect is a skin effect current system patented by Ric- Wil. racers r acing Approved Vendor: RIC-WIL Energy Products Co. 950 Sussex Blvd. P.0, box 232 Broomall, PA 19008 DUP 0838697 SPECIFICATION NO 8544 - VICTORIA Page 43 7.0 EQUIPMENT INSULATION 7.1 GENERAL CONDITIONS - 7.1.1 Keep insulation materials dry at all times during storage and installation. No wet insulation shall be installed. If the insulation becomes wet during or after installation, it shall be r.emoved and replaced with new and dry insulation. Insulation may be protected with plastic film, but must be vented to prevent condensation. 7.1.2 Equipment 24" or less in diameter may be insulated with pipe insulation in which case, the insulation thickness specified in the applicable pipe insulation tables will take precedence over the thickness specified in the "Equipment Insulation Tabulation". 7.1.3 All finishes on equipment, vessels and fittings surfaces will be metal. The exceptions to this are removable insulation, equipment heads,' and J.rregular shapes as indicated in this s pecification. 7.1.4 Insulation index with the code letter "D" included . indicates dual-temperature service. Install the insulation in two layers. Stagger all joints between layers. > 7.1.5 Provide the following insulation to equipment. corrosion protection under 7. 1.5.1 All carbon steel equipment shall be painted per the paint specification. Stainless steel equipment which is not painted shall be protected with mastic at 35 deg F and below and above 35 deg F coat with sodium silicate per this specification. 7.1.5.2 Do not coat with sodium silicate where it is not to be insulated. 7.1.5.3 When sodium silicate (Code 802.1) is used,add red food coloring at the rate of 1 ounce per gallon. Use a minimum of 1 gallon per 100 S.F. Let the coating dry before insulating. Do not apply sodium silicate to items that cannot be covered by insulation on the same day. 7.1.5.4 Where the insilation can get wet and identified on drawings with the letter "G" between the diamonds, heavier metal jacketing and flashing is required as. indicated in the equipment finish section of this specification. 7.1.6 Sketches included in appendix of illustrate methods of installing and insulation on hot and cold systems. this specification finishing removable 7.1.7 All body flanges, manholes, nozzles, etc, are to be insulated (unless specifically excluded) with the same thickness as specified for the equipment. Flanges on nozzles shall be the DUP 0838698 SPECIFICATION NO 8544 VICTORIA Page 44 same thickness as specified for piping. 7.1.8 Leave flanged joints uninsulated until connecting pipe and equipment has been hydrostatically tested by Du Pont, and released to the contractor for completion of insulation. 7.1.9 At flanged joints, stop the insulation 1 bolt length plus 1" from the back of the flange. Do not bevel insulation. DUP 0838699 SPECIFICATION NO 8544 - VICTORIA Page 45 7.2 APPLICATION SPECIFICATION FOR THICKNESS INDICES 49 AND BELOW (35 DEG. F & BELOW) TABLE C2 - 7.2.1 Insulate with polyisocyanurate insulation, (Code 118.1). 7.2.1.1 Use plain joints for thickness indices <47> through <4 9>, 10 through 35 F. 7.2.1.2 Use offset joints for thickness indices <46> and below, 0 F and below. Double layer insulation must be used where tongue and groove or shiplap type insulation joints are not used. 7.2.2 Stagger joints. 7.2.3 Install insulation in a full bedding coat of fibrated asphalt cutback (Code 709). Coat all contact surfaces of the insulation with the same material. 7.2.4 When insulation is installed in double layer, seal the outer layer to the inner layer by a continuous coat of fibrated asphalt cutback (Code 709). 7.2.5 Where insulation terminates at flanges, flanged fittings, etc, cover the end of the insulation and 2" minimum of the , insulation and the adjacent metal with fibrated asphalt cutback' (Code 709) reinforced with organic fiber cloth, open weave (Code 743) . 7.2.6 All cuts for protrusions such as nozzles, pipe, supports, angles, etc, must be tightly fitted. No gaps around these cutouts are permitted. Seal all cutouts at time of application. 7.2.7 Secure insulation in place with 3/8" x .015" thick stainless steel bands and seals (Code 927) 12" on centers. 7.2.8 18-gage stainless steel wire, (Code 921), over masking tape (Code 987) may be used where needed. 7.2.9 Insulate all metal in contact with equipment and which protrudes through the insulation with same thickness as the equipment insulation. Cover the protrusion for a minimum of 12" from the equipment insulation surface. 7.2.10 Apply vapor barrier membrane, (Code 741), over the cylindrical insulation. Overlap adjacent pieces a minimum of 2" at all joints. 7.2.11 The vapor barrier must be applied and sealed against all nozzles before flange covers are applied. 7.2.12 Where insulation cannot get wet and in low abuse areas, provide a finish for heads, cones, irregular shapes, etc, of reinforced mastic. Apply a tack coat of fibrated asphalt cutback (Code 709) and imbed organic fiber cloth, open weave (Code 743). Lap adjacent pieces of reinforcing material a minimum of 2" and DUP 0838700 SPECIFICATION NO 8544 VICTORIA Page 46 eliminate wrinkles. Apply a second coat as soon as the first coat becomes tack free. Both coats must be applied in the same day. (First coat 25 S.F. per gal, second 17 S.F. per gal). 7.2.13 Where insulation can get wet and high abuse areas apply the reinforced fibrated asphalt cutback (Code 709) finish indicated in the above para. Allow the mastic to dry prior to applying a protective finish of reinforced epoxy resin. See the specification for the application of epoxy resin finishes. DUP 0838701 SPECIFICATION NO 8544 - VICTORIA Pag e 4 7.3 APPLICATION SPECIFICATION FOR THICKNESS INDICES <50> THRU <54 > (36 TO 80 F)TAB LE S C2, HI, H5, H6 - 7.3.1 Insulate with polyisocyanurate (Code 118.1) per this application specification. 7.3.2 For acoustical applications, insulate with glass-fiber (Code A10.2). Secure the insulation in the same manner as indicated in this specification. 7.3.3 If cracks or imperfections cannot be satisfactorily closed, replace the affected section of insulation. 7.3.4 Offset or ship-lap insulation is preferred. Where plain joint insulation is used, coat (seal) all butt joints of insulation with fibrated asphalt cutback (Code 709). Coat all irregular metal projections a minimum of 6" from the equipment insulation surface with cork-filled mastic (Code 501). 7.3.5 Stagger joints. 7.3.6 If vessel is large enough, the bent around the tank. insulation board may be 7.3.7 Where insulation terminates at body flanges, skirts, etc, > a beveled end collar (Code 717.6) is required. Do not bevel insulation. See sketches in the Appendix. 7.3.8 All cuts and protrusions such as nozzles, pipe, supports. angles, etc, must be tightly fitted. No gaps around these cutouts are permitted. 7.3.9 Secure insulation in place with 3/4" x .015" thick stainless steel bands and seals (Code 927 ) 12" on cen ters . " Stainless steel wire (Code 921) 18-gage over masking tape (code 987) may be used where needed. DUP 0838702 a^ggmyjHgr i SPECIFICATION NO 8544 - VICTORIA Page 48 7.4 APPLICATION SPECIFICATION FOR THICKNESS INDICES 55 AND ABOVE (80 TO 1200 F)TABLES HI, H2, H5, H6 - 7.4.1 Insulate with calcium silicate (Code 102.1) or (Code 102.2) . 7.4.2 For acoustical applications where elevated temperatures require a calcium silicate/ glass-fiber (Code A10.2) composite insulation system, secure the insulation in the same manner as indicated in this specification. 7.4.3 Stagger joints. 7.4.4 Secure insulation in stainless steel bands and Stainless steel wire, 18 gage needed. place seals (Code with ( Cod e 921 ) , 3/4" 927 ) may X .015" thick 12" on centers. be used where 7.4.5 Close cricks or imperfections by either tamping or filling with insulating and finishing cement, inhibited (Code 502.4). 7.4.6 All cuts and protrusions such as nozzles, pipe, supports, . angles, etc, must be tightly fitted. No gaps around these cutouts are permitted. t 7.4.7 Insulate all metal in contact with the equipment and which protrudes through the insulation, with the same thickness as the equipment insulation. Cover the protrusions for a minimum of 12" from the equipment insulation surface. 7.4.8 Where insulation terminates at body flanges, skirts, etc, install a aluminum beveled-end collar(Code 717.6). Do not bevel the insulation. See sketch in the Appendix. 7.4.9 No scored or grooved insulation is permitted. DUP 0838703 SPECIFICATION NO 8544 VICTORIA Page 4 9 7.5 FINISH 7.5.1 Where the insulation cannot get we t and in low abuse areas, the following finish may be used 7.5.1.1 Use 0.016" smooth acrylic coated aluminum jacketing (Code 716.5). For vertical equipment above 4 ft. in diameter it is more economical to use deep corrugated acrylic coated aluminum (Code 716.7). 7.5.1.2 The heads of equipment and irregular shapes shall be finished with reinforced mastics. Apply a tack coat of insulation mastic (Code 734) and imbed organic fiber cloth, open weave (Code 743). Lap adjacent pieces of reinforcing material a minimum of 2" and eliminate wrinkles. Apply a second coat as soon as the first coat is tack free. Both coats must be applied in the same day. First coat 25 SF per gallon, second coat, 17 SF per gallon. 7.5. 1.3 Lap smooth aluminum jacket a minimum of 3" circumferentially and ^longitudinally. Machine cut jacket to obtain a tight fit. 7.5.2 Where the insulation can get wet and in high abuse areas or where the letter "G" appears between the diamonds on drawings, the following finish is required. 7.5.2.1 For equipment 3'-6"in diameter or less the finish shall be 0.024 minimum thick acrylic coated aluminum (Code 752.1). Secure with stainless steel bands (Code 927) and a breather spring (Code 980) on each band. The 4" spring shall be tensioned to 5". 7.5.2.2 Equipment above 3'-6"in diameter use 0.032" smooth acrylic coated aluminum (Code 751.1), or for vertical equipment over 4 ft. in diameter, deep corrugated acrylic coated aluminum 0.024" (Code 752.3). For highly corrosive areas use the deep corrugated tedlar coated aluminum 0.024" (Code752.4) or smooth aluminum 0.032" (Code TED). 7.5.2.3 CAULKING COMPOUNDS ARE NOT AN WHERE METAL FLASHING CAN BE APPLIED, stiffener rings and similiar protrusions thickness to the side wall finish, fabrication details. ACCEPTABLE SUBSTITUTE Cover all body flanges, with metal equal in See the Appendix for 7.5.2.4 The jacketing longitudinal joints on vertical equipment shall be sealed with closure strips or"Z" joints. The jacket shall recess a minimum of 2" in the joint. Lap the circumferential joint a minimum of 3". Support each course with S-clips (Code 997) on 36" centers. 7.5.2.5 The heads of equipment and irregular shapes shall be finished with a reinforced polyester or epoxy resin system. See Engineering Std. SN221P or the Epoxy Resin System in this DUP 0838704 SPECIFICATION NO 8544 - VICTORIA Page 50 s pecificacion. 7.5.2.6 Immediately after application of metal jacketing, seal all penetrations and possible points of moisture entry with a 3/8" bead (minimum) of caulking compound (Code 813). Do not feather edges. Apply caulking on clean, dry surfaces at a temperature recommended by the caulking manufacturer. 7.5.3 Jackets installed on equipment having a vapor barrier membrane (Code 741) installed over the insulation must be secured with bands. No screws are permitted with finish over membrane. 7.5.4 Cut the metal jacket so that the vertical seams overlap at the center of the nozzles. Where it is practical use metal collars or back-up strips secured by stainless steel sheet metal screws. See sketches in the Appendix. 7.5.5 Install metal beveled end caps, or collars, at all insulation terminations. See sketches in the Appendix. 7.5.6 Use 3/4" x .015"thick stainless steel bands (Code 927) on all equipment. The bands are to cover each overlap and one in the middle for smooth aluminum jacketing. All equipment operating above 35 deg. F <50> requires at least one breather spring (Code 980) per band. Use two breather springs per 30 L.F. of band on equipment operating at or above 200 F<66>. Screws may be supplemented with bands as required to provide improved watertight seams. Use 3/8" long, No.7 stainless steel screws (Code 971.1) on 6" centers. ` 7.5.7 Install the deep corrugated aluminum jacketing (Code 716.7) (Code 752.3) (Code 752.4) in the following manner. Lap corrugated sheets a minimum of 2-1/2 corrugations. Secure laps with stainless steel sheet metal screws, (Code 971.1), on 6-inches centers. Locate screws on ridge of overlap. Use a screw length which does not penetrate the insulation. Support succeeding courses with a minimum of 2 stainless steel "S" clips per sheet. Apply 3/4" stainless steel bands on about 3-foot centers. All openings cut in metal jacketing that provide a gap in excess of 1/8" shall have separate flashing applied of the same material. Seal all cuts and other possible sources of water entry with a 3/8" bead (minimum) of caulking compound (Code 813). See para. on proper application of caulking. 7.5.8 Approved metal flashing and removable insulation details are illustrated in the Appendix of this specification. 7.5.9 For removable/reusable insulation covers on cold systems below 35 F, use rigid insulation covers. Finish to be aluminum in the same thickness as the jacket. See sketches in the Appendix. Seal the joints with caulking (Code 813). For hot systems, the soft type removable/reusable insulation covers are acceptable. See Appendix for the Specification. DUP 0838705 SPECIFICATION NO 8544 - VICTORIA Page 51 rr i-* 7. 5. 10 An acceptab le method of ins tall ing m shown in the Append ix . end c ap s is 7. 5.11 For acousti cal applications. fin ish in 8U)L at i on wi th lead lamina ted aluminum (Code A30.4). 7. 5.11 . 1 the lead 1 am in a t e d a 1 um inum (Cod e P.u rcha sed with an acrylic or tedlar f ini sh . A3 0 .4) c an be 7. 5.11 . 2 The stand ard lead laminate d al umin um hiis a 1 lb ./ s q . f t . le ad bar rier. Fo r severe noise co nd it ions t he jac ket ing c an be pu rcha sed with a 2 lb./sq.ft. lead laminati on 7. 5.11 . 3 Secure th is jacketing wi th band s as i nd icated for sm ooth al uminum in this specificatio n. 7. 5.11 .4 Equipment heads and irregular shap es shall be f in ished wi th loaded masti c (Code A60.5) and re in fo rc ed ope n we av e glass cl oth (Code 710)- Embed clrOth into ma Stic wh:Lch sh all be a minimum thickness of 0.4)14". DUP 0838706 SPECIF 1CATION NO 8544 - VICTORIA Page 52 7.6 FIRE RESISTANT FINISH FOR EQUIPMENT (WHEN SUPPLEMENTARY CODE LETTER "Q" IS USED) - 7.6.1 Finish with .010" thick, smooth (Code 753) or corrugated (Code 753.4),Type 304 or 316 as required, stainless steel jacket. (See paragraph in this specification for alternatives to deep corrugated jacket). 7.6.2 Cover all equipment insulation with stainless steel finish, smooth or deep corrugated as applicable, including body, heads, fittings, protrusions, irregular surfaces, etc. 7.6.3 Lap jacket a minimum longitudinally. Machine cut fit . of 3" circumferentially and and roll jacket to obtain a tight 7.6.4 Gored segments for heads are concealed side and beaded on the other. compound (Code 813) into the bead installation. - ' to be Apply a of each crimped on the bead of caulking gore prior to 7.6.5 Jackets installed on equipment having vapor barrier membrane, (Code 741), installed over the insulation must be' secured with 3/4" x 0.015" thick stainless steel bands (Code 927). No screws are permitted with finish over membrane. When a * vapor barrier membrane is not installed, 3/8" long, No.7, stainless steel screws (Code 971.1) on 6" centers may be used with approval of the Engineering Dept. 7.6.6 Where openings are cut in the metal jacket to fit around nozzles, use metal collars or back-up strips secured by stainless steel sheet metal screws. See sketches in the Appendix. 7.6.7 Seal all penetrations and possible points of moisture entry with a 3/8" bead (minimum) of caulking compound, (Code 813). Do not feather edges. Apply on clean,dry surfaces at a temperature recommended by the caulking manufacturer. 7.6.8 Install stainless steel beveled end caps or collars at all insulation terminations. 7.6.9 Use 3/4" x .015" thick stainless steel bands on all equipment. Use one 4" breather spring (Code 980) on each band. Provide a additional spring per 30 L.F. of band on equipment operating at or above 200 F<66> . 7.6.10 Deep corrugated jacketing may be used on vertical equipment and vessels over 4 feet in diameter. Lap corrugated sheets a minimum of- 2-1/2 corrugations. Secure laps with stainless steel sheet metal screws (Code 971.1) on about 6-inches centers. Locate screws on ridge of overlap. Use a screw length which does not penetrate the insulation. Support succeeding courses with a minimum of 2 stainless steel "S" clips per sheet. Apply 3/4" stainless steel bands on 3 ft. centers. Breather springs on the bands are required. DUP 0838707 SPECIFICATION NO 8544 - VICTORIA Page 53 7.6.10.1 Do not use screws on equipment operating below 35 deg. F since the vapor barrier membrane may be penetrated. Apply 3/4" stainless steel bands on 2 ft. centers. 7.6.10.2 All openings cut in metal jacketing that provide a gap in excess of 1/8" shall have a separate flashing applied of the same material. Seal all cuts and other possible sources of water entry with a 3/8" bead (minimum) of caulking compound (Code 813). See above para. for proper application. 7.6.11 Approved flashing and removable insulation are illustrated by sketches in the Appendix of this specification. 7.6.12 For finishes on cold and hot removable insulation, use 0.010" stainless steel jacketing (Code753). See sketch in the Appendix . 7.6.13 An acceptable method of installing metal end caps is shown in the Appendix. 7.6.14 Insulation support rings, stiffener rings, etc, that protrude beyond the insulation finish on vertical vessels must have a water shed flashing installed per the attached sketches in the the Appendix. DUP 0838708 SPECIFICATION NO 8544 - VICTORIA Page 54 7.7 FIB ERGLASS-REINFIOCED EPOXY RESIN FINISH - 7.7.1 This specification describes the methods and materials used to provide a fiberglass-reinforced epoxy resin finish over insulation. 7. 7. 1.1 This finish system can be used on insulated equipment heads and irregular shapes. 7.7.2 The principal safety hazard is dermatitis. Eye and hand protection is required. This system is solvent free and therefore does not require special ventilation. 7.7.3 Procedure 7.7.3.1 This finish can be applied to polyisocyanurate foam-rigid, calcium silicate, cellular glass or mineral wool without any special preparation required. 7.7.3.2 When applying this finish to fiber glass -insulation it is recommended to lay a lightweight woven glass lagging cloth on the insulation in order to eliminate epoxy resin penetration. Precut a sufficient number of pieces of cloth and allow for a ` minimum of 1" overlap. 7.7.3.3 Fill cracks or openings in the insulation applying finish. before 7.7.3.4 For cold temperature systems, apply the epoxy resin directly over the mastic system when it has become dry. 7.7.3.5 This-system must be applied at temperatures above 32 F (0 C). For ease of application, when outdoor temperatures are below 50 F (10 C), keep epoxy in a warm area until ready for application. 7.7.3.6 The resin is a two-component mix with a pot-life of 20 to 60 minutes after mixing. Mix only the amount resin which can be readily applied. 7.7.3.7 For ease of handling, order material in containers no larger than one gallon. 7.7.4 Application 7.7.4.1 Cut the reinforcing cloth in lengths for ease of handling. Lay the sections of cloth directly on the insulation. Overlap adjoining sections of cloth by 2" min. Cloth can be pinned to the insulation. 7.7.4.2 Mix Alocit Thixotrope 28.96 with hardener (resin base coat) and apply directly to the surface of the cloth and insulation with a stiff bristled brush (cut bristles). DUP 0838709 SPECIFICATION NO 8544 VICTORIA Page 55 7.7.4.2.1 For large areas(10 square feet or greater), such as equipment heads, or where severe mechanical abuse or foot traffic is expected, use 6 x 6 or 8 x 8 reinforcing cloth with a resin base coat of 20 mils wet thickness (80 sq ft per gal.). 7.7.4.2.2 For small areas, and where only moderate abuse is expected, use 10 x 10 to 13 x 13 reinforcing cloth, with a resin b-ase coat of 10 mils wet thickness (160 sq ft per gal). 7.7.4.3 The base coat need not be dry prior to applying the brush application top coat of Alocit Aquacoat Adhesive 28.15. 7.7.4.4 The thickness of the top coat should be 10 mils wet thickness (160 sq ft./gal) for all applications. 7.7.4.5 When ordering Aquacoat Adhesive 28.15, specify desired color. Available colors in stock are white and gray. Other colors available on special order. required. 7.7.4.6 For a non-skid surface texture, broadcast quartz or 70 mesh silica sand in the wet top coat. 7.7.4.7 Clean tools with paint thinners immediately after use. Approved Vendors: ; Epoxy Resins: Alocit Thixotrope 28.96 Alocit Aquacoat Adhesive 28.15 Alcoit Products A division of Warfield co . , Inc. 1005 Sussex Boulevard Broomall, Pennsylvania 19008 Tele: 215-328-9440 Synthetic Organic Reinforcing Cloth 6x6 to 8x8 (for large areas) Elasta Fab No. 894 - Vimasco Corp. PC Fabric 79 - Pittsburgh Corning Corp. Quality Cloth - Quality Service Metals Glass Reinforcing Cloth 10x10 to 13x13 (for small areas) Glass cloth, Style 1659/Geon - J.P. Stevens and Co. Woven Glass Scrim Fabric, Resin Treated Style 1659 - Burlington Industries, Inc. Luben Scrim Fabric Style No. 59 (white) Alpha Associates, Inc. Fiber Glass Scrim Style No. 1659 - Clark Schwebel Fiber Glass Corp. DUP 0838710 SPECIFICATION NO 8544 - VICTORIA Page 56 8.0 DUCT INSULATION 8.1 GENERAL CONDITIONS - 8.1.1 The specific at ion provides for insulation inside outside the duct . or 8.. 1.2 The insulation must be kept dry at all times during storage and installation. The insulation may be protected with plastic film, but must be vented to prevent sweating. 8.1.3 Check all ducts seams and flanges for air tightness since any leak can destroy the insulation vapor barrier. 8.1.4 In the event of a work delay, all possible points of moisture penetration must be sealed before work is halted. DUP 0838711 ^asgg;gasisB33tBS.;^;Baafc :g'-ggw*ata~" SPECIFICATION NO 8544 - VICTORIA Page 57 8.2 APPLICATION SPEC. FOR DUCTS (SUPPLEMENTARY CODE LETTER "J") INSULATION OUTSIDE THE DUCT -OUTDOORS - 8.2.1 This specification is for ducts where the insulation can get wet or in high abuse areas, with operating temperatures to 300 F. <76>J<+>. 8.2.2 The insulation shall be polyisocyanurate (Code 118.1). 8.2.2.1 The insulation thickness shall be 1" for temperatures to 250 F. <71>J<+>. The insulation thickness shall be 1 1/2" for temperatures above 250 F. <72 >J<+>. 8.2.2.2 Where the insulation can cover stiffeners and flanges, increase the thickness by 1/2", thus providing an uninterrupted j acket. 8.2.3 Where the.duct ttemperature is between 35 and 80 F. with the insulation index on^drawings <50>J<+> through <54>J<+>, apply fibrated asphalt cutback (Code 709) to all butt ends of insulation where it terminates such as at flanges and all insulation joints which are not the offset (shiplap) type. 8.2.4 Secure insulation to the duct. Duct surface clean. Use insulation adhesive (Code 826) 150 F max. top, sides and bottom. must be <6 1 >, on 8.2.4.1 For ducts greater than 18" on sides and bottom install Spindle anchors (Code 964.1),(Code 964.2) on 16" centers and no greater than 2" from any edge. Use anchor adhesive (Code 817) on ducts operating up to 200 F <60>. Weld pins (Code 979) must be used on ducts operating above 200 F. 8.2.5 For additional in information, see sketches in Appendix "H" . DUP 0838712 SPECIFICATION NO 8544 VICTORIA Page 5 8 8.3 APPLICATION SPEC. FOR DUCTS (SUPPLEMENTARY CODE LETTER "J") INSULATION OUTSIDE THE DUCT - DRY, LOW ABUSE AREAS - 8.3.1 This specification is for ducts and pipe indoors, dry and low abuse areas in the temperature range of 33 to 375 F.,and indicated on drawings <50>J<+> through <84>J<+>. 8..3.2 The insulation shall be glass fiber (Code 112.6) and (Code 112), with a factory applied finish. 8.3.3 For square or rectangular ducts use glass fiberboard insulation (Code 112.6) with factory applied FSK finish. 8.3.3. 1 Where insulation can cover stiffeners and flanges, increase the thickness by 1/2", thus providing an uninterrupted j ac ket. 8.3.3.2 For anti-sweat and temperatures to 150 F. <61> use 1" thickness insulation. Above 150 F. <62> refer to the insulation thickness Table ,,C4. 8.3.3.3 Secure insulation to the duct in the following manner. Duct surface must be clean. Use insulation adhesive (Code 826) to 150 F. maximum temperature or (Code 810) to 200 F. maximum temperature. For ducts greater than 13" on sides and bottom, install spindle anchors (Code 964.1) or (Code 964.2) on 16" centers and no greater than 2" from any edge. Use anchor adhesive (Code 817). For ducts operating above 200 F. <66> weld pins (Code 979) must be used. 8.3.3.4 Seal the duct seams with 2 mil foil tape (Code 999). Use 3"wide tape on butt joints and 5" wide tape on corner joints. 8.3.3.5 Where pins are required to secure the insulation system, impale the pin through the jacket, bend and depress or cut the ptn over the washer and cover with strip of 2 mil foil tape (Code 999) . 8.3.4 For round ducts and pipe use one-piece, hinged glass fiber insulation (Code 112) with factory applied ASJ finish and longitudinal lap adhesive. 8.3.4.1 Where the insulation can cover flanges, increase the thickness by 1/2", thus providing an uninterrupted jacket. 8.3.4.2 For anti-sweat and temperatures to 150 F. <61> use 1" thickness insulation. Above 150 F. <62> refer to the insulation thickness Table C4. 8.3.4.3 Insulate the fittings with routed or molded fiberglass two piece fitting covers (Code FFC). DUP 0838713 STRCITXCATION NO 8544 VICTORIA 'Page 5 9 Finish the fittings with one piece PVC fitting covers (Code 748). 8.3.4.4 Seal the circumferential seams with 3" wide matching ASJ tape Code 999). 8.3.5 All tape must be applied in accordance with the tape manufacturers recommendations. 8.3.5.1 The surface where the tape is to be applied must be free of oil or grease and dry. The area temperature shall be above 32 deg. F. Do not stretch the tape, but lay it on the surface and apply firm wiping pressure on the tape with a nylon squeege. 8.3.6 For additional information, see sketches in Appendix "H". DUP SPECIFICATION NO 8544 - VICTORIA Page 60 8.4 FINISH FOR INSULATION OUTSIDE THE DUCT - 8.4.1 Finish on ducts that are outdoors, in washdown or high abuse areas are to be metal covered. 8.4.2 Finish with .016" stucco embossed aluminum jacketing (Code 716) or (Code 716.5). The embossed surface must be specified in the order. Cross break the flat surfaces on metal jacketing to eliminate a wrinkled appearance. Deep corrugated aluminum (Code 716.6) or (Code 716.7) shall be used on ducts greater than 48" on any side. Lap all metal jacketing a minimum of 3" in a water shed fashion. Install insulation metal corner beading 2" X 2" .X .020" minimum. 8.4.3 Secure the embossed aluminum jacketing in the following manner. Over the insulation, provide metal bands .020" X 3" wide minimum secured with appropriate pins, bent and depressed over the band. Locate bands at jacketing overlap. Screw (Code 971.1) metal jacketing to the bands 4" on center. Provide a bead of caulking compound (Code" 813) between all metal overlaps on all horizontal ducts. 8.4.4 Secure the corrugated aluminum jacketing in the following - manner. Secure Z type sub-girts by welding or with self dr illing/self tapping screws to the duct stiffeners or flanges. 1 Sub-girts to be 16 gage galv.steel and spaced on 18" centers maximum. Attach the jacketing to the sub-girts with stainless steel screws spaced on 6" centers maximum. Seal the head of each screw with caulking compound (Code 813). 8.4.5 Install metal collars, at all insulation terminations. All openings in metal jacketing in excess of 1/8" shall have flashing applied of the same material. Seal all cuts and other possible sources of water entry with a minimum 3/8" bead of flashing compound. 8.4.6 Where the insulation can get wet, in high abuse areas, for irregular surfaces, and for removable insulation where metal jacketing cannot be properly installed, apply a polyester/epoxy resin system. See Engineering Std. SN221P or the Epoxy Resin Specification included in this specification. 8.4.7 Where the insulation cannot get wet, in low abuse areas, for irregular surfaces, and for removable insulation apply a tack coat of insulation mastic (Code 734), .03" wet thickness. Reinforce with open weave cloth, (Codes 710 or 743). Embed the reinforcing in the wet tack coat. Lap adjacent pieces of reinforcing a minimum of 2 inches, and eliminate all wrinkles and protruding edges. Apply a second coat .08" wet thickness as soon as first coat becomes tack-free. both coats must be applied the same day [first coat 50 SF (square feet) per gal., second coat 20 SF per gal.] Apply a final finish coat of asphalt aluminum coating after the finish is dry where metal jacketing is not used . DUP 0838715 SPECIFICATION NO 8544 VICTORIA Page 61 8.4.8 Seal all points of possible moisture penetration with 3/8" bead of caulking compound (Code 709). 8.4.9 For additional information, see sketches in Appendix "H". DUP 0838716 SPECIFICATION NO 8544 - VICTORIA 9.0 APPENDIXES APPENDIXES "A"- INSULATION SYSTEM SKETCHES FOR PIPE Page 6 2 "B"- HANGER ROD RAIN SHIELDS "C"- INSULATION OF TRAPS "D"- REMOVABLE INSULATION COVERS RIGID AND SOFT TYPE INSULATION SYSTEM SKETCHES FOR TRACED PIPE INSULATION SYSTEM SKETCHES FOR COLD EQUIPMENT INSULATION SYSTEM SKETCHES FOR HOT EQUIPMENT INSULATION SYSTEM SKETCHES FOR DUCTS OR BREECHING DUP 0838717 jjmmu *J& iiiiU-<iiiiiiBilHiiiiiiiiiiMiiiliMi SPECIFICATION NO 8544 - VICTORIA 9.1 APPENDIX "A"- INSULATION SYSTEM SKETCHES FOR PIPE Page 63 DUP 0838718 sucttfe-'jarE .;fct5i>Bisg t.MaKal.ji'iliM-'- -; fSj-ly 5e-I i- _-- ---a4g iI. .... ^ 7~i-^zA .. ,-s jjcxamgawra.^ naj.;Lii.;-;s.t Bia KPPLNBXX INSULATION SYSTFM SKKTCHF.S FDR PTPF PAGE A Do not bovol insulation Beveled and cop, oo SN217P Attach aluminum fackat Elevation Vortical Sactlan to tha cap with a minimum of two icrawt equally spaced Overlap adfo ta provide watershed. Use wire or tape ta hold in place until screw is applied in tha lap For outdoor or wot area installations, apply flashinp compound. BEVELED END CAP FOR TERMINATION OF INSULATION DUP 0838719 APPENDIX "A" INSULATION SYSTEM SKETCHES FOR PIPE FITTINGS PAGE Z Baauty Bond METAL EHD CLOSURE DUP 0838720 SPECIFICATION NO 8544 VICTORIA Page 64 9.2 APPENDIX "B"- HANGER ROD RAIN SHIELDS - 9.2.1 APPLICATION - 1 . Trim bottom of rain shield (Code 901) to follow the contour of the outside diameter of the pipe insulation. .2 Temporarily position rain shield on hanger and al low approximately 3/16" clearance between bottom of skirt and top of pipe insulation. 3. Mark location of cylindrical portion of rain shield on hanger rod . 1. Remove rain shield. 2. Remove all loose dirt, grease, and scale from this section of hanger rod. 4. Apply a continuous ^bead of flashing compound (Code 813) around the circumference of the rod where t.he rain shield neck area will make contact. 5. Open rain shield and install on hanger rod with the . cylindrical section (neck area) fully bedded in the wet flashing compound. .6 Pull tight and secure the cylindrical section with stainless steel hose clamp. Fasten the skirt overlap of the rain shield fastener (code 998) located approximately bottom of the skirt. with 3/4" a nylon from the .8 Punch hole for nylon fastener with special punch available from Premetco International, Inc. DUP 0838721 APPENDIX "B" PAGE i End Via* HANGER ROD RAIN SHIELDS Hangar Rod Dia 0 <ta) Va- Vi Va- Vi Va - ll/a V/* - IV* Rata SMaid Ho. RS 38-12 RS 58-34 RS 78-111 RS 114-112 Flara Angka A 20* 30* 40* SO* Skirt Langlti L(ln) #y< 7'/a '/* * DUP 0838722 .. JiB,; SPECIFICATION NO 8544 - VICTORIA 9.3 APPENDIX "C"- INSULATION OF TRAPS - Eauimant bama nffltfmmn *: r-.-; i- : PAGE 65 TABLE - MSULATKN OF 1BAFS Typo at Trap it In. taro Mpo Ahaap UMnsUataS Trap at Trap WapulroP tody Paqulraa hnarallto uekar Disk Ptoai and TharmostPic Imouisa Laval Chamoar Onfiea Thatmal Expansion Thamwatane Y No Vas NO NO No No Vas YM YM Vaa Vas No NO NO NO Yta ym Naiaa: 1. Whara waeifiad. it meftaa <X bar* pips ira nacataary o prwtoa auocooung tor prooar no oparanon. ilia iaa*h puarpt whan nacaasary around traps ta praraet parsanna I frsai canrael with hot siirfecat. DUP 0838723 SPECIFICATION NO 8544 - VICTORIA Page 66 9.4 APPENDIX "D" - 9.4.1 SOFT TYPE REMOVABLE (REUSABLE) INSULATION COVERS FOR PIPING AND EQUIPMENT OPERATING UP TO 650 DEG. F - 1. Conditions for use: o Wherever removable insulation covers are required, the soft type covers shall be used per this specification. o For indoor or outdoor use, see material qualifications. 2. Insulation thickness guide (minimum installed thickness), a. Below 300 deg. F - 1" thick for pipe. - 1-1/2" thick for flanges and 'equipment. b. 300 to 500 deg. F - 1-1/2" thick for pipe. - 2" thick for flanges and equipment. c. 500 to 650 deg. F - 2" thick for pipe. - 3" thick for flanges and equipment . d. 500 to 650 deg. F - Dow jacketed process systems Indoors. - See materials paragraph "A-l" for thickness. 3. Materials a. Insulation for Indoor use where insulation will not get wet. (Also see Item 7.) 1. Low density (1.05 lb/ft3) Ref. SN200M, Code 204.1. - Insulation Wool TIW Type I (Order without metal mesh) . Owens-Corning Fiberglass Corporation. - Thickness to be 6" compressed to 4", 3" minimum installed . - For pipe less than 2" diameter, compress 4-1/2" to 2" . DUP 0838724 2. Low Density (2.5 lb/ft3) (Code 204.2). Insulation Wool TIW Type II (Order without metal mesh) . - eigfciat,. a: SPECIFICATION NO 8544 - VICTORIA Owen 8-Corning Fiberglass Corporation. Page 67 b. Insulation for indoor and outdoor use. 7.) (see also Item 1. High density insulation (9 to 11 lb.ft3) (Code 209). Temp-Mat, Pittsburgh Corning Corporation, Inc. Burglass 1200, Burlington Industries. Insulgard Type 2, Southern Mfg. Co. Claremont 1200 Glass Blanket, Claremont Co., Inc. Filomet D, Alpha Associates. Note- Should"the insulation get wet, it will maintain its integrity when it has become dry. 2. Medium density insulation (6 lb/ft3). (Also see Item 7.) Kaowool, Babcock & Wilcox Company Thermo -Mat , Johns -Manvi lie Sales Corporat ion Fiberf rax Fiberma t B1anke t , Carbo rund urn Out side cover finis h (cold side ) on indoor appl i cat ions and finish on both sides for o utdo or applica t ions to 500 deg . F. High temp erat ur e glas s cl oth , silicone co ated (Code 746). Alpha-Mari tex , Fiber G1as s/ Silicone St yl e 3259- 2-SS or 8301-2- ssL. Al pha Assoc iate s , Inc -- Style 2300 - Si 1icone coate d (for ind oor us e on iy) Southern Textil e Corporatio n . - Thermoglas S , St yle G0P752/9 736 , Amate x Co rpora t io n. Ins ide cover f inish (hot side) on i ndoor appl icat i ons and out door applic at ion s abov e 500 deg . F. Can also b e used as a outside c over finish on indoor appl icat ions . High t era perature cl oth , PI ain ( Code 745) Alpha-Mari tex, St yle 2025/9383. Alpha Asso c iate s , Inc O C TJ O 00 CO 00 -IS4J cn . ! -Bifflia:;a;:i.S-lii SPECIFICATION NO 8544 VICTORIA Page 68 Thermoglass, Style G10P752, Finsih 9731 Amatex Corporation. Style 2025 - Finish 100, Southern Textile Cor por a tion . e. Accessories 1. High-temperature glass thread Teflon coated (Code 993). Alpha D-24 Machine D-39-Hand Alpha Associates, Inc. 2. Lacing Ring and Lacing Washers (stainless steel). - Lacking Ring, ,P*rt No. 111-0201-00. - Lacing 2 -' Hole washers (use 2.Ring). 1" Diameter, 2-Hole, Part No. 033-0201-20. - Available from: H. A. Jones Co., Inc. Box 34, Dayton View Station Dayton, Ohio 45406 A.G.M. 110 Shawmut Road Canton, MA 02021 - Pan-Ty Cable Ties, PLT Locking Ties Heat Stabilized Color: Black (Panduit Color No. 30). Panduit Corporation Note: Size cable tie to assure appropriate tensile strength. 4. Measurement, Fit and Clearance o When installed, the overlapping or butted edges of the cover must be tight to prevent any chimney affect or safety burn hazard. Chinking is not acceptable. o Removable insulation must overlap permanent insulation a distance equal to the thickness of the soft insulation being applied or minimum of 3 inches whichever is greater . o It is recommended when possible that the fabricator do all dimensional take-offs on custom applications for fit and clearance. DUP 0838726 SfECXJICATIOH HO 8544 VICTORIA Page 69 o Where design and construction of soft covers for a unit (vessel, manifold, etc) are such that similar, or multiple pieces exist, the vendor shall supply an installation drawing and/or assembly instruction to aid in installing the covers. o Cover vendor shall provide Du Pont with a fabrication sketch of the cover and maintain a record of the sketch in file with proper identification in the event a replacement cover is required. o Provide access to pressure bulbs, thermowells and sample/purge connections (separate covers are required) for a specific area. o Keep the number of segmented covers for a specific area to a minimum without exceeding the weight limit. 5. Design and Construction'"" o Locate horizontal seams on the bottom or sides of pipe or equipment, where possible. o Weight for practical working pieces not to exceed 50 ) pounds unless approved by Du Pont. Use the recommended low density insulation where handling the cover may be a problem. o Provide adequate stitching to prevent migration of the insulation within the cover. Use a minimum of one stitch per foot. o Provide permanent stainless steel tag or approved alternate identification outside the cover which will not be affected by heat and environment. o Maximum spacing of lacing rings to be 3" for pipe covering and 4" for equipment covers. o Maximum length of pipe cover to be 8 ft. unless the site specifically requests a longer cover. o When requested, provide tell-tale hole on the bottom of each cover to identify leaks. o Joints - To prevent a chimney effect at blanket to blanket joints. Use either Butt or Overlap joints. Where overlap is used, provide 3" tapered ends and draw-down wire (16 ga sst or monel). A 1" seam will be provided to house the wire or cord. Kevlar cord may be used in lieu of wire. DUP 0838727 SPECIFICATION NO 8544 VICTORIA Page 70 o Hog rings will not be used except on the inside cut. o Sewing shall be double straight stitched at 8 to 10 stitches per inch, with each row spaced a minimum of 1/8" to a maximum of 1/2" apart. Fabric seams will be inside seams whenever possible. Final closing seam can be outside and must be machined stitched. 6. Approved Vendors o It is recommended that a vendor near the plant site be cons idered. o In selecting a vendor, the number of soft covers required and the complexity of the covers will be a determining factor. o Vendors must be approved by the Engineering Department. 7. Insulation Thermal Efficiency The following information may be used thermal efficiency of the insulation this specification. as a guide to the materials indicated in l ' Example: An insulation with a K factor of .20 is twice as efficient (approximately 1/2 the heat loss) as a insulation with a K factor of .40 for the same thickness. Insulation Material K Factor (btu/(h)(ft2)(deg.F/In.) @200 deg. F Me an @300 deg.F Mean Insulation Wool TIW Type 1 Compressed to 1/2 the Thickness Insulation Wool TIW Type 2 Temp-Mat or equal (11 lb/ft3 density) Kaowool or equal (6 lb/ft3 density) .40 .35 .30 .28 .29 .57 .50 .42 .32 . 36 DUP 0838728 Page 70.1 ALTERNATE METHOD OF SECURING SOFT COVER DUP 0838729 APPENDIX "D" TYPICAL RIGID REMOVABLE/REUSABLE INSULATION AT FLANGED FITTINGS (REQUIRED FOR COLD TEMPERATURE SYSTEMS) Page 3 CODE 743 SYNTHETIC ORGANIC PIBER CLOTH-OPEN WEAVE. CODE 709 FIBRATED ASPHALT CUTBACK.-- FOR IRREGULAR SURFACES AND REMOVABLE INSULATION. 4 CODE 813 FLASHING COMPOUND.-- SEALANT AT ALL POINTS OF MOISTURE ENTRY. 5 CODE 743 SYNTHETIC ORGANIC FIBER CLOTH-OPEN WEAVE. CODE 709 FIBRATED ASPHALT CUTBACK.-- SAME AS ITEM 3 ABOVE 6 CODE----- REMOVABLE INSULATION. 7 CODE 927 STAINLESS STEEL BANDS AND SEALS. 8 CODE ----- PERMANENT INSULATION. 9 CODE 741 VAPOR BARRIER MEMBRANE. 10 CODE 716 SMOOTH ALUMINUM JACKET. NOTE: ON COLD SYSTEM, DO NOT LET ALUMINUM JACKET EXTEND UNDER REMOVABLE INSULATION. APPLY BEAD OF FLASHING COMPOUND ON THE LONGITUDINAL JOINTS OF THE REMOVABLE INSULATION. ALTERNATE: FOR FLANGES USE PREFABRICATED RIGID (FRP) REMOVABLE/ REUSABLE INSULATION COVERS, (CODE 749.4) CJ Sjj o 00 u 23 w J.* APPENDIX "D" TYPICAL RIGID REMOVABLE/REUSABLE INSULATION AT FLANGED FITTINGS (REQUIRED FOR COLD TEMPERATURE SYSTEMS) Page 2. 3 CODE 743 SYNTHETIC ORGANIC PIBER CLOTH-OPEN WEAVE. CODE 709 FIBRATED ASPHALT CUTBACK.-- FOR IRREGULAR SURFACES AND REMOVABLE INSULATION. 4 CODE 813 FLASHING COMPOUND.-- SEALANT AT ALL POINTS OF MOISTURE ENTRY 5 CODE 743 SYNTHETIC ORGANIC FIBER CLOTH-OPEN WEAVE. CODE 709 FIBRATED ASPHALT CUTBACK.-- SAME AS ITEM 3 ABOVE 6 CODE----- REMOVABLE INSULATION. 7 CODE 927 STAINLESS STEEL BANDS AND SEALS. 8 CODE ----- PERMANENT INSULATION. 9 CODE 741 VAPOR BARRIER MEMBRANE. 10 CODE 716 SMOOTH ALUMINUM JACKET. HCTE: OS COLD SYSTEM, DO NOT LET ALUMINUM JACKET EXTEND UNDER REMOVABLE INSULATION. APPLY BEAD OF FLASHING COMPOUND ON THE LONGITUDINAL JOINTS OF THE REMOVABLE INSULATION. ALTERNATE: FOR FLANGES USE PREFABRICATED RIGID (FRP) REMOVABLE/ REUSABLE INSULATION COVERS, (CODE 749.4) DUP 0838732 APPENDIX "E" i'l -\ [ *C INSULATION SYSTEMS FOR TRACED PIPE Page I * Tfrfcat Croas lacHen Figure 4A - Tfcpteat Spaoar Dalai TYPICAL TRACE* AMANCEMEMTt DUP 0838733 APPENDIX "E ) INSULATION SYSTEMS FOR TRACED PIPE Page 2 DUP 0838734 Typfcil MuUp* Ttaoara TYPICAL TIUen ARMNG&CXn SPECIFICATION NO 8544 - VICTORIA Page 72 9.6 APPENDIX "F"- INSULATION SYSTEM SKETCHES FOR COLD EQUIPMENT DUP 0838735 APPENDIX fi^wirmbn ( , MINUS 1QC*F TO PLUS 35*F Page 1 LIi4 l*f ( anfU mnd wM Sactimt A--A PICURE I - AHCLE-IEOM SUPPORT DETAIL TOP DUP 00 W CO .Jkg.r:|E> -i-^l'^y :~osfei:^.iaij*jgi||j|i.iMiii-;gs XP'PSIYDXX *F" *wn T>TEM5 FOR COLO EQUIPMENT, MINUS 100*P TO PLUS SSF Page 2 Cantinu* i4a wall tw aa4 nf lacalali _4 fa 4 indiaa Pull>aaaf kaJJiwf Mi a4 sL Reinforced vapor-barrier mastic with FRP or epoxy on head continued down over side wall 4 to 6 inches below where top edge of jacket will be. I jachaf (a vapar-kairiar with flashinf a<acMfi4 Jaekar Ttk wll -Vapor-barrier membrane Wm >2* IncafaHan Jain caalar - FIGURE 3 - ALTERNATE INSULATION SYSTEM FOR VERTICAL TANKS TOP HEAD FLAT. CONICAL. OR DISHED * Taa PiajacKaa t--i ka P<ai4a4) DUP 0838737 ' Uaa mm pr*ca4ura far aa laaalataJ Miila aacaai flaskin* skauM ka cat la aafsIJa JlaMlar al iasalarian InstaaJ af *** * llliww i jttlll 4FIGURE - FLASHING AT NOZZLES APPENDIX "F* INSULATION SYSTEMS POR COLO EQUIPMENT. MIHUS 100*N TO l*LU5 3S*f -Altamaia band* ar mhm *a rita l*a cimaifaraaflal ban4t Reinforced vapor-barrier mastic, with FRP or epoxy Jainf (aalai A M.(S\V\\VVGOaK t-Vaasal ull^aat baMinfl taaiar Page 3 nCURE 5 - HORIZONTAL CYLINDRICAL EQUIPMENT INSULATION - SINGLE-LAYER DUP 0838738 APPENDIX "F" INSULATION SYSTEMS FOR COLO EQUIPMENT, MINUS 100*P TO PLUS 35*P Page 4 DUP 0838739 FIGURE < - HORIZONTAL CYLINDRICAL EQUIPMENT DOURLE LAYER APPENDIX "F* INSULATION SYSTEMS FOR COLD EQUIPMENT, MINUS lOO^F TO PLUS 35* F Page 5 FulUcaaf kakkiny **(*, Firm* bank* mnww^ Umm Uiitabia an lay*. far *ik* |M baffaa haak inaalarian Jaekat (If r**uir*k> Attach racial wira* a, banks f* **y>*n*k yirth banks far lia*f insulatian ******* Fla* insulatian far su**arf anyl Camylataly Iniufat* lay far ****** 12* baiaw wtlar* it kayartt (ram haak insula tian Reinforced vapor-barrier mastic, with FRP or epoxy E*ui**i*nt structural anyl* lay <u***rr Sactfan A--A FIGURE 7 - VERTICAL CYLINDRICAL EQUIPMENT WITH STRUCTURAL ANGLE LEG SUPPORTS Tank kall-'**^ * laakat (if r**uir*k) -Vapor-barrier membrane Insulatian FuUoat Mfiny (aalar Vs" a 1 * lany mks walk an 12'cantars Canfinuaua tys'klantata* r*k laa* Tank h**k lashiny DUP 0838740 .Insulatian su***rts fack sralkak FIGURE 7A- VERTICAL CYLINDRICAL EQUIPMENT WITH SKIRT SUPPORT - figfoasj ti'M ; ...i^-------.uhaim ijar APPENDIX "F* INSULATION SYSTEMS FOR COLO EQUIPMENT, MINUS 100*F TO PLUS 3S*F Pfaiiii Zarttimieus %mdim fd .Filter bfck (typical) Page 6 Tap M 'U'ii, X I'len, red t!M an 12 Shall Fullweet bedding sealer Skewer (typical) Jaint laaiar (typical) Bands er wires Anyla Iran er flat bar with 2'min watershed, walk csntinueus Planfa intulatian fleshing sanpeund baud Finish Lajend a Salt die + l' i Salt lenyth + 1* e T Vl'min i a T - 1/* T, Intuletien thickness Pwllweet baddlnf faalar . See Flashing Detail for Vertical Equipment tgUfitii Fleshing cempaund baad Match lina r PlfMta IA -- Upper Oatail af PI wiped Vertical Eaui patent FIGURE ( . FLANGED VERTICAL EQUIPMENT DUP 0838741 APPENDIX "F" INSULATION SYSTEMS FOR COLO EQUIPMENT, MINUS 100*F TO PLUS 3S*F Page 7 Flfura SB -- Laawr Dlaka4 HaaW Men Straight Tvifant ia Balt Laxffti Plus I Inch ar Mara Fifara 1C Lawar Oi*^M HaM Pkara Siraiflit Tanfaat ia Laaa Tkan Bali Laaik Plaa I lack PI CURS t - PLANS CD VERTICAL EQUIPMENT (CONFO) D U P 0838742 SPECIFICATION NO 8544 VICTORIA Page 73 9.7 APPENDIX "G INSULATION SYSTEM SKETCHES FOR HOT EQUIPMENT - DUP 0838743 APPENDIX "G" 1^3, Vtutl- INSULATION SYSTEMS FOR EQUIPMENT 35 TO 1200F {2 TO 649BC) ^-1 ! Iimiltilw Jack** ()f required) with nestle cut cut ta eaceed nezzle die Flashing, upper C'acv Flashing cMt*uif ____ Page I Fleshing, lewer piece Detail -- Split Flashing Frevide nazsla length sufficient fat halt ramavai witheut damaging insulatian FIGURE I - FLASHING AT NOZZLES DUP 0838744 SHED ANGLE (FOR EQUIPMENT OPERATING ABOVE 300F 149C) APPENDIX "G* INSULATION SYSTEMS FOR EQUIPMENT 35 TO 1200F (2 TO 649C) Page 2 Continue head finish end of insulation head * 4 to 6". Finish on head continued down over side wall 4 to 6" below where top edge of jacket will be. Seal jacket to finish with flashing compound Ban4 taekat (Aluminum) Insulation Joint sealer where required, See specification. ' FIGURE 3 - INSULATION SYSTEM FOR VERTICAL TANKS WITHOUT WATER SHED ANGLES Vassal DUP 0838745 FIGURE 4 - CYLINDRICAL EQUIPMENT - HORIZONTAL APPENDIX INSULATION SYSTEMS FOR EQUIPMENT 35 TO 1200F (2 TO 649C) V V" die red-i Band lug17^ First bands segmented batwaan suitabla fastenings on legs, for side and bottom haad insulation Finish Attoch radial wtresor bonds to sagmantad girth bands (or haad insulation support PiM insulation (dr support angle Reinforced mostie Page 3 "Equipment structural angle lag support Saetion A A "(T + W) min -- increase if oauipmant is to ba traced or hove penal coils FIGURE 5 - VERTICAL CYLINDRICAL EQUIPMENT WITH STRUCTURAL ANGLE LEG SUPPORTS Vessel -Finish Joint sealer, see specification. ' Insulation Tank ^Extend Min insulation thicknoss r finish below support Insulation supports tack woldod (7* -- Vj) min * incroasa if oquipmont is to bo traced or hovo pane! coils \ lonq rods welded contors -Continuous V4" diomotor rod loop FIGURE 4 - VERTICAL CYLINDRICAL EQUIPMENT WITH SKIRT SUPPORT DUP 0838746 APPENDIX "GM INSOLATION SYSTEMS FOR EQUIPMENT 35 TO 1200F (2 TO 649C) Finish Continuous V4* die rod Filler block Page 4 Top hoc V* die k 1 * long red welded on 12" cantors Continuous welded joint w| --Vte" (min) Fobricofed Anglo Dotail Legend a Belt die + 1" b Bolt length + 1" c * (T + V2*) min -- see note d T - Vj* -- see note T Insulation thickness Note: Incroeso i( equipment is to bo traced or have panel coils. Figure 7A - Upper Detail FIGURE 7 - FLANGED VERTICAL EQUIPMENT Skewer Joint sealer (typical) Bonds or wires inish Continuous seal weld Standard angle (preferred) or fabricated angle. Min angle thickness Via* --Flange insulation See Flashing Detail for --sk.wer Vertical Equip See Flashing Detail for Vertical Equip. If scheduled remove! is required, metre Hong* eovtn removable Standard angle (preferred) or fabricated angle. Min angle thickness Skewer Flashing compound beod Match line DUP 0838747 APPENDIX "G' INSULATION SYSTEMS FOR EQUIPMENT 35 TO 1200F (2 TO 649C) Page 5 Figure 7B - Lower Dished Head Where Streight Tengent it Belt Length Plus 1 Inch er Mere Match line Fig 7A Filler hteck Skewer If scheduled removal it required, make flange cevert removable Bands er wires -Insulation -Finish See Flashing Detail on Vertical Equip -V*" dia * 1" long rod welded on 12" centers "Continuous V*" die rod Sloshing compound Finish Figure 7C -- Lower Dished Hood Where Streight Tengent is Loss Then Dolt Length Flus 1 Inch FIGURE 7 - FLANGED VERTICAL EQUIPMENT (CONT'D PROM PAGE 4) DUP 0 8 3 8 7 4 8 APPENDIX mG INSULATION SYSTEMS FOR EQUIPMENT 35 TO 1200*F (2 TO 649*c> Page 6 DUP 0 8 3 8 7 4 9 SHED ANGLE (FOR EQUIPMENT OPERATING BELOW 300F 149C) APPENDIX "G" Page 7 FLASHING ON VERTICAL EQUIPMENT WHERE BODY FLANGES AND STIFFENER RINGS ARE INSULATED (FOR EQUIPMENT OPERATING ABOVE 300F 149C) APPENDIX "G" Page 8 FLASHING ON VERTICAL EQUIPMENT WHERE BODY FLANGES AND STIFFENER RINGS ARE UNINSULATED (FOR EQUIPMENT OPERATING LESS THAN 300F 149C) APPENDIX "G" FLASHING ON VERTICAL EQUIPMENT WHERE BODY FLANGES REQUIRE REMOVABLE _____________INSULATION COVERS________ Page 9 DUP 0838752 (ELEVATION VIEW) pV/3 /2 j r ^ c <? 5fr'r:ys9//yu E _^/ y<ESSL. //r^'i- ..; ~7ct we to /7 tree 7/4 *'*/ i f" /-+ (," p.,f* * tsrje f / , . *, ij. "///< fG f/pA. 2.' fhr9`irt^" p-pez z.-)y/s ' /.Tou ~?fuci /90 C'r/l Y. 2.. i/y U- Z C `i T/r i f f?C* Alc. vcZSZ SS C/U.ertS*~ Sn/e*T 3 " T/fcr 3.- //<.'' 2 2 C F /SirO/e ff/Si/L ? Tfcrs f=^n FjL L '*'?? Ly /j OF LC t c/r^ s tutC *'C / / " 7V"f4- OF Fc&rjpe. i\ &CLT <if r c Fr/ tcp of . /F rsl, & G TTo fs*A /: Fr2/. & F ~n. 4 //C- T ff- l.p n^ff.eC + //or} -f /" /ft e> LT F f. s s F l y<r /e. S* s yf'-Z SFrer~C^- x_r sSz> 7~ SfS 7~c ssU> <~ J* 7~0 S-pFO^y SS'SJ'ZSC *1 T f C*S /yysT^ff c f? 7 res/ jrrcx. n~ f- ^ott f^vot^-r y~e> z>~ r c< /*.v.^c yy& ir n l f sy&of- c c 7- pj c>.*fc y. DUP 0838753 SPECIFICATION NO 8544 VICTORIA Page 74 9.8 APPENDIX "H" BREECHING - INSULATION SYSTEM SKETCHES FOR DUCTS OR * DUP 0 8 3 8 7 5 4 APPENDIX HM Page i Insulation, stoggorod ' Finish DUCT SKETCH DUP 0838755