INTERNAL CORRESPONDENCE b hMICALS and plastics P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303 in.TM) See Attached Distribution List D.'e June 22, 1977 Orgn4iing Dept. Gen 11emen: RECEIVED JUL 'j :S77 G. F. HURLET Subieci Guidance for Compliance with EPA Asbestos Regulation Enclosed is an outline providing guidance for compliance with Environmenta1 Protection Agency regulation, 40 CFR 61, Hazardous Air Pollutants, as it applies to the removal and disposal of ashestos-containing insulation and the notification of appropriate regulatory agencies. The outline summarizes key requirements of the regulation and suggests a standard format for use in notifying regulatory agencies. It is recommended that current location procedures be reviewed and any appropriate changes implemented to conform with specified removal and disposal requirements. It is also suggested that locations within the same EPA Region coordinate the timing for initial notification of the proper regulatory agencies to make the submissions reasonably concurrent (August 1 might be a realistic target date). It is further suggested that larger locations will find that annual notifica tion on a calendar year basis (in early December of the prior year, except for 1977) using the best estimate of expected activity will minimize their paper work. The EPA regulation is in addition to an OSHA standard governing worker exposure (29 CFR, Chapter XVII, Section 1910.1001). However, only EPA requires notifica tion of removal and disposal activities. The cost impact of modifying proce dures to meet EPA regulations appears to be quite variable within Chemicals and Plastics, but would seem to be in the range of $100,000 - $200,000 total, on an annua I bas i s . Any requests for clarification of the plan requirements should be directed to Mr. D. G. Moshier of the Maintenance Operations Team. Copies of the regula tion can be provided upon request (they may be found in the Environment Reporter at 121:0461). RAH/w R. A. Huber Maintenance Operations Manager UCC 017295 i GUlDAflCE^&dEfittPfc * ANC&WliJtt EPA ASBESTOS REGULAHOtryy 1. REGULATION AND APPLICABILITY Regulation - 40 CFR 61, Subparts A and B App 1 icabi1ity - To the demolition of structures or renovation of equip ment and piping that involves removal of more than 160 square feet or 260 lineal feet of insulation containing more than one percent asbestos by weight, either in a single project or a predictable series of projects over the course of one year that are additive to this amount. OVERALL REQUIREMENTS OF REGULATION Practices - Comply with defined removal and disposal practices. Notificat ion - Provide timely notification of EPA. KEY REQUIREMENTS - REMOVAL PRACTICES (1) Insulation shall be removed prior to demolition where the demolition would likely damage and expose insulation. (2) Insulation must be wetted prior to removal and kept wet until disposal is accomp1ished. (3) Insulation on pipe or equipment which is to be removed in sections must have exposed surfaces wetted and kept wet during dismantling. (4) Stripped insulation must not be dropped or thrown to the ground. Dust tight containers or chutes must be used for lowering insulation removed that is more than 50 feet above ground level. KEY REQUIREMENTS - DISPOSAL PRACTICES (1) No visible emissions of insulation are allowed in transport to the disposa1 site. (2) No visible emissions may result from disposal operations. (3) For disposal' areas one of the following requirements must be met: (a) A six-inch earth cover is provided over disposed insula tion within 24 hours. (b) An effective resinous or petroleum-based dust suppression agent is applied at the end of each operating day. (c) A natural barrier adequately deters public access to the site. UCC 0172% 2. inch) warning signs are [See Attachment 1, 61.25] ;.QUtREMENTS -"EPA~NOTlFlCATION I TimingEf*A and applicable States are to be notified either: ^/ '(a) Annually, or (b) 10 days prior to planned demolition or renovation, or (c) As soon as possible after beginning an unplanned (emergency) removal project. The above notification requirement applies, whehever^thjsjtota^amount for the project or time period exceeds 160 square feet of equipment --ipr 260 lineal feet of pipe insulation. Office to be Notified - [See Attachment 1, 61.04] Federal: Director, Enforcement Division Environmental Protection Agency (Regional Office City Address) State: (Applicable only in the following CSP states) California (Sacramento County) (Say Area) Georgia New York North Carolina Suggested Text of Notification letter The attached notification relative to the demolition and/or renovation of facilities containing friable asbestos insulation is provided per requirements of kO CFR 61, Subpart B, Section 61.22 (d) Please contact the writer if there are questions concerning information contained in the notification. Signed UCC 017297 3. NOTICE OF INTENT TO DEMOLISH OR RENOVATE STRUCTURES, EQUIPMENT OR PIPING INVOLVING FRIABLE ASBESTOS INSULATION (1) Name of Owner _______ Union Carbide Corporation (2) Address of Owner (Location Street Address) (3) Description of Facility ________ Various buildings, equipment and piping used in manufacture and distribution of chemicals and plastics. An estimated xx square feet and yy lineal feet of insulation to be removed. (A) Address of Site _______ (Same as item 2 above) (5) Scheduled Start and Completion Dates ______(Either calendar year or other specified dates) (6) Nature of planned demolition or renovation and methods employed Demolition of obsolete facilities and renovation of existing fac i 1 i t i es . (7) Procedures employed Insulation wetted before removal, lowered to ground, disposed in a site which is (fenced or protected by natural barrier or covered daily). (8) Name and address of disposal site (Either same as 1 and 2 above or information for contractor site) (9) Agency ordering demolition Not applicable UCC 017298 (1) The regulation app]ies to friable asbestos which would mean insula tion containing more than one percent asbestos by weight which can be reduced to powder, when dry, by hand pressure. Any insulation purchased prior to 1975, containing asbestos as reinforcement, would meet the definition of friable asbestos and be subject to the regula tion. New insulation does not contain asbestos. (2) A standard text for a notification letter and a format for the notice (filled in with standard responses or indication of the type of response) are included. , (3) For locations with a reasonable amount of continuing activity involv ing insulation removal, paperwork would be minimized and made more routine if notification were made annually (in December for the coming year) using a best estimate of insulation quantities involved. Other locations may find that annual notification is unnecessary. {k) Recognize that an Occupational Safety and Health Standard, 29 CFR, Chapter XVII, Section 1910.1001, "Toxic and Hazardous Substances" impose certain requirements for personnel equipment, clothing, monitor ing, and medical examinations in work areas involving exposure to asbestos dust. There is a certain amount, but not total overlap with the EPA regulation. (5) The EPA regulation applies to any work done at a facility whether by company or contract personnel. Company personnel involved with contractors should assure that notification responsibility is assigned to the contractor in the work specification, or performed by the company. (6) It is suggested that disposal sites for asbestos be fenced (but not posted) even where another approved alternative requirement is being met to avoid future problems from uncovering the material i nadver ten11y. UCC 017299 X f ' -jr yi / ATTACHMENT I --------------------------------- Excerpts from EPA Hazardous Air Pollutant Regulation ENVIRONMENTAL PROTECTION AGENCY REGULATIONS ON NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS (40 CFR 61; 38 FR 8820, April 6, 1973; Amended by Code of Federal Regulations. Volume 40, Revised as of July 1, 1976, 41 FR 27 9 67, July 8, 1976; 41 FR 33264, August 9, 1976; 41 FR 34629. August 16, 1976. 41 FR 36918 September 1, 1976; 41 FR 40108, September 17. 1976; 41 FR 40467, September 20, 1976; 41 FR 43148, September 30, 1976, 41 FR 44860, October 13, 1976; 41 FR 46559, October 20, 1976; 41 FR 53017, December 3, 1976; 41 FR 54758 December 15, 1976; 41 FR 56805, December 30. 1976) Sobpart A--General Provision* 3 61.04 (a) All requests, reports, applications, submittals, and other communications to the Administrator pursuant to this part shall be submitted in duplicate and ad dressed to the appropriate Regional Of' flee of th Environmental Protection Agency, to the attention of the Director, Enforcement Division. The regional of* fixes are as follows: Region I (Connecticut. Maine. Htfflp* iOLrt, Massachusetts. Rhode Island, Tar* ment), John F. Kennedy Federal Building, Sor.cn, Massachusetts 02203. Region II (New York. New Jersey. Puerto Rloo, Virgin Islands), Pederul Office Build* mg, 20 Federal Plaza iFoley Square), New York, N T. 10007. . Region in (Delaware, Dtsvrtct of Columbia, PeQC'ylvania. Maryland, Virginia. West Vlr- rlnlal, Curtis Building. Sixth and Walnut Streets, Philadelphia, Pennsylvania 19106. Region TV (Alabama. Florida, Georgia. MJe- sUatppi, Kentucky, North Carolina, South Carolina. Tennessee), Suite 300. IVJl Peach- Me Street. Atlanta. Georgia 30309. Regloa V (Dllnol*. Indiana. Mlnnaots, Michigan. Ohio. WLscouain). 1 North Wacktr Drive. Chicago. Illinois 90606. Region VI (Arkansas. Louisiana, Hew Mexico, Oklahoma. Texas), 1600 Paeuraoo Afreet, Dallas. Texas 76201. Region VII (Iowa. Kansas, Missouri, Ne braska) . 1735 Baltimore flereet. Kanaaa City, Missouri 63106. Region VTII (Colorado. Montana. North Da kota. flouth DaJtota, Utah. Wyoming), 106 Lincoln Tower*. I860 Lincoln Street, Denver, Colorado 90203. Region LX (Arizona. California, Ha4fl, Nevada. Ouam. American Samoa), 100 Cali fornia Street. 3aa Francisco, California 94111, Region X (Washington, Oregon, fdaJbh, Alaska). 1200 Sixth Avenue, Seattle, 'Wash ington 99101. (b) SecUon 112(d) directs the Admin istrator to delegate to each State, when appropriate, the authority to implement and enforce the national emLssloq stand ards for hazardous air pollutants Tor staUonary aources_located In such State. Ail jafoirnatlon required to lie submitted to-EPA under paragraph (a) of thlauc tion, must also be submitted to the ap propriate State Agency of any Stale to whioh this authority has been delegated (provided, that each specific delegation may exempt sources from a certain fed*tfai or Statl reporting requirement). Thr eppropri&te - mailing addreai for thoae Spates whoser delegation request has been approved U as follows: P-Ca)lforDla: Bay Area Air Polhrtkm Control District, 9*9 ZD2a Stract, aap Frmoctaco, CA M 20*. Sscrtmento CountY Air Pollution Control District. 3701 Branch Center Read, Sacra mento. CA 96671. (L) Stats of Georgia, Ehrironmeatal Pro tection Division. Departmeht'of Natural Re- urce*. 27(7 Washington Btreet, 8 W At lanta, Georgia 30334. t> (HH)--New Tor*; New Tort State Depart ment of KnvlromnenUj Conservation, $0 Wolf Road, Albany. New York 12233. attention': Dbrt&oa of Air 2-eioances. [40 FR 48347, Ociober 15, 1975^ (Il> North Carolina Environmental Man agement Commission. Department of Natural aud Economic Resources. Division of Envi ronmental Management. P.O Box 27607. Ra leigh. North Carolina 27011. Attention: Air Quality Section. Subpart B--National Emission Standard for Asbestos S 61.22 Emission standard. (d) Demolition and renovation: The requirements of this paragraph shall apply to any owner or operator, of a demolition or renovation operation who Intends to demolish any institutional, commercial, or industrial building (in cluding apartment buildings having moro than four dwelling units), structure, facility, Installation, or portion thereof whJch contains any pipe, duct, boiler, tank. reactor, turbine, furnace, or struc tural member that is Insulated or fire proofed with friable asbestos material, except as provided in paragraph (d) (1) of this section; or who Intends to reno vate any Institutional, commercial, or In dustrial building, structure, facility. In stallation. or portion thereof where more than 80 meters (ca. 260 feet) of pipe in sulated or fireproofed with friable as bestos material are stripped or removed, or more than 15 square meters (ca. 160 square feet) ot friable asbestos material used to Insulate or fireproof any duct, boiler, tank, reactor, turbine, furnace, or structural member are stripped or re- mov-d- UCC 017300 (2) Written notice of intention to de molish or renovate shall be provided U the Administrator by the owner or opera tor of the demolition or renovation oper ation. Such notice shall be postmarkec or delivered to the Administrator at least 10 days prior to commencement of demo lition. or as early as possible prior tc commencement of emergency demolition subject to paragraph (d> (6> of this sec tion. and as early as possible prior to commencement of renovation. Such no tice shall include the following Informa tion : (1) Name of owner or operator. (ii> Address of owner or operator. (iii) Description of the building, strjcture. facility, or installation to be de molished or renovated. Including the size, age, and prior use of the structure and the approximate amount of friable asbestos material used for insulation and fireproofing. (iv> Address or location of the build ing. structure, facility, or installation. (v) Scheduled starting and comple tion dates of demolition or renovation. (vt) Nature of planned demolition or renovation and method(s) to ^>e em ployed. (vil) Procedures to be employed tc meet the requirements of this paragraph and paragraph (j) of this section. (viii) The name and address or loca tion of the waste disposal site where the friable asbestos waste will be deposited. (lx) Name, title, and authority of the State or local governmental representa tive who has ordered a demolition whicf Is subject to paragraph (d)(6) of th): section. 61*25 Waste disposal sites. (b> Warning signs shall be displayc< at all entrances, and along the propei t line of the site or along the perimeter u the sections of the site where asbestos containing waste materia) is depositr" at Intervals of 100 m (ca. 330 ft) or lcrexcept as specified in paragraph (d) c this section. Signs shall be posted In sue a manner and location that a person nu easily read the legend. The warm signs requited by this paragraph sh ' conform to the requirements of 20" x 14 upright format signs specified In 29 Cl 1910.H5(dM4J and this paragraph Th signs shall display the following lege:, in the lower panel, with letter sizes nr styles of a visibility at least equal t those specified in thus paragraph. LfCF.NU Asotstos Waste Divosai. Sits Do Not Crc.vte Dust Breathing Asbesl.-'x U Hazardous to Your Health Notation l" Sans Serif. Gothic or Dtock Sans Serif. Gothic or Block 14 Point Guthjr Spacing between linr> .shall bo at lc'r equal to the height ot the upper of th t-vo tin^v Loca tion Bound Brook Brownsvi1le Elk Grove 1 ns titute Marietta N i agara Falls Seadrift Sistersvi 1 le South Charleston Taft 1*echnical Center Texas City Torrance Latex Plants Distribution UCCI DISTRIBUTION LIST Plant Manager R. A. DeCoudres W. W. McManus J. 0. Zimmerman H. J. Karawan C. A. Wales G. C. Merz 0. L . Go r i s A. W. Boyd C. A. Ke i 1 T. L. Rapp J. W. Biddle D. L. Engle J. A. Grady - H. L. Robinson Plant Maintenance Manager Asst. Plant Manaqer P. A. Schultz J. L. Goodson A. L. Barefoot R. C. Glock P. Barna C. E. Rogan, Jr. T. J. Oliver G. W. Bartlett R. L. Shomo C. A. McNei11 R. G. Link L. W. Pha i r R. N. Bates A. G. Stephens W. E. Shacke1 ford T. 0. B 1 urn J. S. Kn i gh t J. M. Stogdon - - R. A. Mendez D. L. Brucker EP/OH Coordinator G. R. Stringer L. T. Windel R. L. Foster R. G. Hull C. C. Duffie1d V. D. Dutcher J . A. Helm D. G. Olds L . E. Carlson J. L. Worstel1 A. W. Carlson D. L. White G. F. Hurley^-^t J . B. Leverton J. P. Alexander K. G. Morlock A. R. Randall J. E. Stevens V. Vega F. D. Bess 5H N. W. Gaines - 511 R. C. Hie ronymus - 511 E. Q. Hu 11,MD - 511 R. T. Kramer 512 M. G. Manetti - nyo.^6 A. E. Montagna - NY0.21 D. G. Moshier - 511 R. E. Pee 1e - 5 11 E. C. Powe11, Jr. - 511 T. P. Raby - 312 M. D. Seymour - 511 R. D. Stief - 511 B. H. Thomas - 511 D. T. Watters - 511 UCC 017301 />/ 6- 121:0401 jT^'VIKONMENTAl^ROTE' TtONj)CENCY REGULATIONS ON NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS (40 CFR 61. 38 FR 8820. April 6. 1973; Amended by Code of Federal Regulations. Volunic 40. Revised ns of July |. i`>75; 40 FR 42195. September II. 1975; 40 FR 45171. October 1. 1975. 40 FR 48292. October 14. 1975; 4u l-'R 48347. October 15. 1975:40 FR 50719, October 31. 1975; 40 FR 58646, December I 8. 1975: 40 FR 59729. Dccembet <i.i 1075: 41 FR 1914. January 13. 1976; 41 FR 4264, January 29. 1976; 41 FR 7750, February 20, 1976; 41 FR I 1820, March 22. 1976: 41 FR 19633. May 13. 1976: 41 FR 21450. May 26. 1976.41 FR 24885. June 21. 1976: 41 I K 27967. July 8, 1976; 41 FR 33264. August 9, 1976; 41 FR 34629. August 16, 1976; 41 FR 36918. September 1, 1976 41 FR 40108, September 17. 1976; 41 FR 40467, September 20, 1976; 41 FR 43148. September 30. 1976; *U Fit 44860. October 13. 1976, 41 FR 46559. October 20, 1976) Subpart A--General Provisions 61.1)1 Applicability. The provisions of this part apply to the owner or operator of any stationary source for which a standard is prescribed under this part. f>1.02 Urfinilion*. As used In this part, all terms not de fined herein shall have the meaning given them in the act: ia> `'Act" means the Clean Air Act (42 USC. 1857 et seq.). <b "Administrator" means the Ad ministrator of the Environmental Pro tection Agency or his authorized repre sentative. (cl "Alternative method" means any method of sampling and ana}}zing for v.n air pollutant which is not a reference method or an equivalent method but which has been demonstrated to the ~. Administrator's satisfaction to produce, m specific ca.scs. results adequate for his determination of compliance. * | VI I R 159V,. Mjy }, 1 974) (d) "Cuimneinvil" means that an own er or operator lias undertaken a continhous . program of construction or modification or that an owner or operator has entered into a contractual obligation to undertake and complete, within a rea sonable time, a continuous program of construction or modification. lc> "Compliance schedule" means the date or dates by which a source or cate gory of sources is required to comply with the standards of tills part and with any steps toward such compliance which are set forth in a waiver of compliance under 5 61.11. ;f i "Construction" means fabrication, erection, or installation of a stationary source. *g` "Effective date" Ls the date of pi omulgation in the Federal Rf.ciste* of an applicable standard or other regu lation under tins part. *h) "Equivalent method" means any method of sampling and analyzing for an air pollutant which has been dernons.iatcd lo Die Administrator's satisfac tion to have a consistent and quantita tive known iclatlonship to the reference method, under specified conditions. fit "Existing source" means any sta* tionary source which is not a new source. cj > "Modification" means any physical change m. or change In Ihc method of operation of. a stationary source which me leases the amount of any hazardous air pollutant emitted by such source or which results in the emission of any hazardous air j>ollutant not previously emitted, except that: (1) Routine maintenance, repair, and replacement shall not be considered physical changer., and <2> The following shall not be con sidered a change in the method of operation: <i) An increase in the production rate. If such increase does not exceed the op erating design capacity of the stationary source: (ii> An Increase in hours of operation. Oo "New source" means any stationary source, the construction or modification of which is commenced after the publi cation in the Federal Recister of pro posed national emission standards for hazardous air pollutants which will be applicable to such source. (1> "Owner or operator" means any person who owns. leases, operates, con trols or sui>ervis06 a stationary source im> "Reference method" means any method of sampling and analvzing fot an air pollutant, as described m ap pendix B to tins part. <n> "Startup" means the setting in operation of a stationary source for any purpose. <o> "Standard" means a national emission standard for a hazardous air pollutant proposed or promulgated under th:j part. (p' "Stationary source" means any building, structure, facility, or installa tion which emits or may emit any air pollutant which has been designated as by the Administrator. 6103 Abbro ialion*. The abbreviations used in this part have the following meanings: 'C--Degrees Centigrade, cfm--Cubic feet per minute. ft:--Square feet, ft --Cubit feet. *F--Degiecs Fahrenheit. In--Inch. ! -- Liter, ml --Milliliter. M--Molar, m'--Cubic meter, mn--Nanometer, oz--Ounces. v/v--Volume pei volume, yd'--Square y&rua. w.g.--Water gage. inHg--Inches of mercury. inHO--Inches of water, g--Grams, mg--Milligrams. N--Normal. R--Degree Rankine. min--Minute sec--Second, avg -- At erase. I D -- Inside diameter. O D --Outside diameter. /.g--Micrograms (10-* gram>. % --Percent. Ilg--Mercury. Re--Beryllium, g Ol.lH A.Mnss. (a' All requests rtrporTo, .ipphca'-lons, submittals, and other communications lo tiie Administrator pursuant to this part shall be submitted in duplicate and ad dressed to the appropriate Regional Of fice of the Environmental Protection Agency, to the attention of the Director. Enforcement Division. The regional of fices arc os follows: Region I (Connecticut. Maim* New Hamp shire. MassaclHiNCt'ii. Phooe JV.and, Ver mont). John F. KcuikU) rvdej-U Building. Boston, Massachusetts 02203. Region H (New Tork. N>w y. Enteric Klco. Virgin Islands), Federal OiUce Build- ug. 2G Federal Plaza (Foley Square). New \orK. N.Y. 10007. Region III (Delaware. D's'Hct 'A Columbia. reiin*yivftnju, Maryland. Virginia, Wcll Vir- iniim). Cuius UulMLug. 6lxih and Walnut Streets, Philadelphia, rVnuM'lvnuia 1910G. Region TV < A1 .vbarr.:i. Flonrtn. OcO'gta. M.e- -.;sippl, Keniucky. Non)i C.nohu.i, South rqrolma. Trnnevre), friute 300. Will Peach- i ce Suett, Atlanta.. Gecn^ia 3030^ Region V (Illinois. IndMim. Minnesota, Michigan. Olilo, Wisconsin). 1 North Wackei Orlvf. Chicago, Illinois oi)b06 Tlrgioo VI (Arkansan. Louisiana, Nct- Mexico. OMc.homa. Texas), 1000 Paficn.on street, Dallas. Texas 70201. Pa*gion VII (Iowa. Kun-us. Mtsionil. Nc- :-'Rbka). 1735 Baltimore Street. Kansan City, m- jsdui i hjioe. RCvituu VIII iCc'iorado. Mnni-am., No-vh Da- Sooth Dakota, Uuui. Wyoming). 1S9 >jii<oln Toners. 1800 Lincoln Sinei, CX-ntor. Culoiado 80203. Region IX (Arizona. CalUoi m. Haxftfl, Nevada. Guam. American .Samoa), 100 Callfen nia Street, S.m Franc h.go, Call lorn la 24 111. Region X (Wor.htntrion. O'egon, Idaho, .Uivm), J200 Sixth Avenue, :vauu\ Wash ington 08101. <b) Section 112d` dnccU the Admin istrator to delegate to each Sm.e. v.hcn Appropriate, the authority to implement and enforce the national emisrloi) stand ards lor hazardous ah* pollutants for sta tionary sources located in such State. Ail infoimotion icquncd to be .siibiimietl to EPA under paragraph 'r\> of this '.v. non. must also be submitted to the i- propriatc State Agency of any Stale to whioh this authority has been delegated 'provided, that each specific delegation may exempt sources from a certain fe-cm! or Stali reporting requirement). 1 n. appropHatc mailing address for Uuv-e 1 2-1 7-76 Copytigni $ 1976 by The Bveou ol Noi>onol (See. 61.04(b) | 23 UCC 01 7302 FEDERAL REGULATIONS wwhose iirlf'GJUion request hn-s been ,m*ovcd Is ns follows: 1A) [rcw:rvcil| (D) SUU U. AJbam*. Air Pollution Con trol DItImoo. Air DoiluUoxi Cont_rol Comml*. ston. 648 9. MeDoocrugh STUc-ot, Montgomery, Alabama 30KH. 14 I IK 4(l4f*7. ScplemlKr 2(1. 1 ^ 7 61 (Cl-Hil | reserved | <F) California; Day Ar<*s Air Pollution Control District, 93u tills St.. San Francisco. CA 94109 Del Norte County AJr Pollution Control Dis trict. Courthouse. Crescent City. CA 96531 Fresno County Air Pollution Control District. 515 S. Crflar Avenue, Fresno. CA 93702 Humboldt County Air Pollution Control Dis trict. 5G00 S. Broadway, Eureka, CA 06501 Kern County Air Pollution Control District. :700 Flower St. (P.O. Box 997). Bakers field. CA 93.102 M.idern County Air Pollution Control Dis trict. 135 W. Yoscmltc Avenue. Madera, CA 93637 Mendocino County Air Pollution Control Dis trict. County Courthouse, Uklnh, CA 95482 Monterey Bay Unified Air Pollution Control District. 420 Church St. (P.O. Box 487), Sillnns. CA 9.1.901 Northern Sonoma County Air Pollution Con trol District. 3313 Chanalc Hd . Santa Jlosa. CA 95104 Sarmmento County Air Pollution Control District. 2701 Branch Center Road. Sacra mento. CA 05827 San Joaquin County Air Pollution Control District, tnoi E. IlaTriton St. (PO. Dox 2009). Stockton. CA 95201 Stanislaus County Air Pollution Control Dis trict. 820 Scenic Drive. Modesto. CA 95350 TY1nlt7 County Air Pollution Control Dis trict. Box AJ. Wravcrvlllc. CA 90093 Venlutir County Air PcnulWn Control Dis trict. 625 E. Santa Clara St. Ventura. CA 93001 'U H<i4M7l thmber t >a75: 4 I I R ' 145*'. m.m 2f*. l')7f. 2; ; ;; i 0 7 ; 41 | U V-M Alien si 9. 411 i HH, Ss.plcu.lv. I 7. I 97u} x. 41 I It <G)--State, of Colorado. Colorado Air Pollution Control Division. 4210 East llLh Avenue, Denver, Colorado 80220. J IT. t K Mi7 I 9. Ociohcr 31. 197V >11) Suic m (mmciiKiii. Department ->i Eiivji onincntai Prolcctiun. Stale Offce Budding. Hat Hard, Conm.-cucm 06115 141 1 k 11 K:n, M.mit io7r; < III k I ] U M I VCiJ j (l.l Savr of Crurrl*. KiivUmiiihmIM Prn- l rc' Dlvllon. P'-i'vrtincnl of Nn'ural Re- r'-p*, ;'7<* Wn-htucton Blreet. SVC., AV- liuu.a. Gcurc'.a ju.iJ1 ui i it :11>ik' :i. 197(ii iMUOl lUMlU'dl (D state of Lndt.m.v lUni:a -a.r Pollu tion ConWol Hoard. 1-t'ti) Wc-.t Michigan Street, CitXirtnfttvinv Indiana 4C20G. \Ai lit 4 11 4 K. Sepu-mKr 31). 19761 |iv^rvnl| (IM .State n( Maine. Department of Envi ronmental Protection. State House. Augusta, kUlnr 0-1.1.0. | 40 I K 5'7:<). Ikwemlvt 3*1. 1975! ( V| j -cwr sed I Washington Street, B ' ton, Mawachu* setts 02111. [4 ! IR 19633 Mj; 1 3. 19761 (JC) State of Michigan. AJr Pollution Con trol Division. Mlchlgaa Department of Natu ral ItR-ources. Steven* T. ?.!ason Building, nth Floor. Lansing, Michigan 40926. (41 ! R 1914. January 13, 19761 (Y)-(DO) [reserved) 61.03 I*roh ifiilril .nrli\ it ic. (a) After the effective date of any standard prescribed under this part, no owner or operator shall construct or mod ify any stationary source subject to such standard without first obtaining written approval of the Administrator in accord ance with this subpart, except under an exemption granted by the President under section 112(c) C2) of the act. (EE) New Hampshire Air Pollution Sources, the construction or modification Control Agency. Department of Health and Welfare, StAte Laboratory Buildlnii, ITazen Drive, Concord. New Hampshire 03301. f which commenced after the publicai) -a date of the standards proposed to bv applicable to such source, are subject i > tills prohibition. 14 1 I R 9633- Mjy 13. 1976( (IT). (GG) {reservedj b> After the effective date of any standard prescribed under this part, no (HH)--New Tor*: New York State Depart. - owner or operator shall operate any new rneru of EnvtronmeotAl Conservation 50 Wolf Hoad, Albany. New York 12233, attention: Division of Air Resources. [40 PR 48347, October 1 5. 1 975} source m violation of such standard ex cept under an exemption granted by the President under section 112(0 <2) of the act. (II) J icwrved| (JJ)--State of North Dakota. State De partment qf Health, State Capitol, Bl6marcJc, North nrttqta 56501. | 4 1 ! R 448.59. Ociubcr 13. 1 9761 (K K.). ( LL) | reserved | <c Ninety days after the effective date of any standard prescribed under this part, no owner or operator shall operate any existing stationary source in viola tion of such standard, except under & vnivcr granted by the Administrator in accordance with this subpart or under .MM)--State of Oictjon. Dcparimcni of Dm ii onmcntal Quality. 1234 SW Moi rlson Street, Poi (Jand. Oregon 97205. J4 1 f R 7750, IVbrujry 20, 1 9761 INNMUW) | reserved) (VV) Commonwealth of Virginia. Vir ginia State Air Pollution Conlioi Board. Hcom 1106, Ninth Street Ofnce Build an exemption granted by the President under section 112(c) (2) of the act. id) No owner or operator subject to the provisions of this part shall fail to report, icvise reports, or report source h.*st results as requ:red under this part. 61.06* l)r|rriniiiAlim of conslrm'MOR ur nu><li (7 <*n I ioi>. ing. Richmond. Vugim* 23219. Unon wril.lcn application by an owner [4 1 IK 8346. lebru.iry 26. 1 9761 or operator, the Administrator will make i\vw> Hi Washington; State of Wash ington. Department of Ecology, Olym pia. Washington 98504. Hi) Northwest Air Pollution Author ity, 207 Pioneer Building, Second and Pine Streets, Mount Vernon, Washing ion 98273. Hli) Puget Sound Air Pollution ControJ Agency, 4 3 0 West Harrison Street, Seattle. Washington 98119. Hv) Spokane County Air Pollution a determination of whether actions t aken or intended to be taken by such owner or operator constitute construction or modification or the commencement thereof wilhm the meaning of this part. The Administrator will within 30 days of receipt of sufficient information to evaluate an application, notify the owner or operator of his determination. 6*1.07 A j j * 1 i r a|o n for a||>ro\j| ol < otiMriM lmii or tnodi 11';ilion. Control Authority. North 811 Jefferson, Spokane. Washington 99201. c v> Yakima County Clean Air Author ity. County Courthouse, Yakima, Wash- la) Tlic owner or operator of any new source to which a standard prescribed under this part is applicable shall, prior to the dale on which construction or trclmi 03901. modification is planned to commence, or [4(1 I R 58649. December 18. ! 975J Hvri Olympic Air Pollution Cvimol Ailh*ri\'. 120 Fast Slate Avenue. Olvnipo. w.vhuicMn onsoi. (vil) Font Iiut'.i Air Pollution Conlioi AnSuite 7GA1 H. NE Ha^.cl Dell Avenue, v.nicotu cr. WaHiUmion 06065. [41 | K 4 264. J.nni.iry 29, 1976} I XXi *[ Z/. i 11, v i veil I. (A \ \). HillH) | reserved| . within 30 days after tlie effective date m the case of a new source that already has commenced consiiuclion or modifia*..on and )rv. not begun operation, sub nut to Hie Administrator an application lor anpiova! of such construction or modification A separate application shall be submitted for each stationary source, Uj i Each application shall include: 1 > Tnc name and address of the ap- pbcant. (CCC>--US. Virum Islands: U S. Vu - (2 i The location or proposed location pin I'dands Department of Conservation of the sotn cc. and Cultm nl Affairs. P.O. Box 578, Chn r- (3 Technical information describing lotlr Amalie. St. Thomas, U S Virgin the proposed marine. s7e. design, operot- IHnndx 00801. inft design capacity, and method of oper 14 i 1 R 346 29. Annul 16. |976| (1) 01 >) | resci ved | . ation of the. source, including a descrip tion of any equipment to be used for control of emissions. Such technical in t\V) Mu.i.sachtj^etlA Department of 139 IR 379S7. Ouoln-i 25. 1974; 40 IR Pm-!ronmei)taj Quality Engineering. 18169. Aptil 25. I97.S. 40 IR 42195, Division of Air Quality Control, 600 Si-picmbui II. I 975 i formation shall include calculations of omission estimates in sufficient detail to permit assessment of the validity of such calculations. Enviionmenl Reporter UC'C 017303 [Sec. 61.07 (b)(3)! 24 ,,oOOS tMISSIONS UI.UIO^A ' /I OH jijinr'!)* ,\(lin!iiilr;ilnr. * fa> The Administrator will, within 60 day.' of receipt of sufficient information ;o evaluate an application under S 61.07. notify llic owner or operator of approval or intention to deny approval of con* struclion or modification. (b> If Uic Administrator determines that a stationary source for which an application pursuant to 61.07 was sub mitted wi11. if properly operated, not rati** emissions in violation of a stand ard. he will approve the construction or modification of such source. <c) Prior to denying any application f`- approval of construction or modifica tion pui suant to this section, the Adminivtrctor will notify the owner or operator making such application of the Admin istrators intention to issue such denial, together with: <]> Notice of the information end findings on which such intended denial is based, and 12) Notice of opportunity for such owner or operator to present, within such time limit as the Administrator shall specify, additional information or argu ments to the Administrator prior to final ,.ction on such application. id' A final determination to deny any application for approval will be in writ ing and will set forth the specific grounds rn which such d -mal is bailed. Such final determination v/ill be made within 60 days of present ition of additional inforinnMon or arguments, or 60 days after the final date specified for presentation, if no presentation is made. <c) Neither the submission of an ap plication for approval nor the Admin istrator's granting of approval to con struct or modify shall: U) Relieve an owner or operator c: legal responsibility for compliance with ?*\y applicable provision of this part or of any other applicable Federal. State, or local requirement, or <2> Prevent the Administrator from implementing or enforcing this part or taking any other action under Hie act.. 61.09 Noliflcnlitm of -Inrlup. fa) Any owner or operator of a source which has an initial startun a Per the effective date of a standard p; escribed under this part shall furnish the Admin istrator written notification as follows: (1) A notification of tne anticipated date of initial startup of the 'omce not mere than 60 days nor less than 30 days prior to such date. (2> A notification of the actual dale of Initial startup of the source within 15 days after such date. 61.10 Stmrrr rt|,.rl!ng nnd v.nher TC* 'a' The owner 0r operator cf any existing source, or ; ny new source which a standard prescribed under this part is applicable which had an Initial .startup which preceded the efTcUivc date of a standard prescribed under this pare .shall, within 90 days after the effective date, provide the ioilowing information in writing to the Administrator: it) Name and address of the owner or operator. (2) The location of the source. <3i The type of hr./..udous pchutar.U emitted by the stationary source. (4) A brief description of the nata:?. size, design, and method of operation of ihe stationary source including the op erating design capacity of such source. Identity each point of emission for each hazardous poLlutant. (5) The average weight per jnont.h of the hazardous materials being processed ly the source, over the last 12 months preceding the date of the report. <6> A description of (he existing con trol equipment for each emission point. n ' t 12-17-76 Copyrtghi C 1976 by The Bureou of Notionol Affow*, Inc. [Sec. 61.10(al(6)J UCC 017304 r*A zardous emissions 121:0403 (j) Primary control dcvicc<$> for each hazardous pollutant. rti> Secondary control dcvice<$> for each ha7-ardous j>ollutant. riji) Estimated control efficiency (per cent) for each control device. (7) A statement by the owner or oper ator of the source as to whether he can comply with the standards prescribed in this part within 90 days of the e/TecUve date. . (b> The owner or operator of an existIni; source unable to operate in compli ance with any standard prescribed under this part may request a waiver of com pliance with such standard for a period not exceeding 2 years from the effective date. Any request shall be in writing and shah include the following information: (1) A description of Hie controls lo be installed lo dimply willi iic sundurd. (2) A coinpiuntc schedule, including the due each Mep towjrd compliance will Ik: reached. Such list shall include js j minimum the following dates: (i) Date by which contracts for emis sion control systems or process modifica tions will be awarded, or date by which orders will be issued for the purchase of component parts to accomplish emis sion control or process modification; ui' Date of imitation of onsite con struction or installation of emission con trol equipment or process change; fiii) Date by which onsite construc tion or installation of emission control equipment or process modification is to bo completed; and Ov) Date by which final compliance is to be achieved. <3> A description of interim emission control steps which will be taken during the waiver period. (c' Changes in the information pro vided under paragraph 'a) of this section shall be provided to the Administrator within 30 days after such change, except that if changes will result from modifica tion of the source, as defined In 61.02 (ji, the provisions ol 61.07 and 5 61.08 are applicable. (d) The format for repotting under this section is included as appendix A of Jus part. Advice on reporting the status of compliance may be obtained from the Administrator. 61.11 W.ihrr i>f i'nitpli.inrr. iat Based on the information provided in any request under 5 61.10. or other in formation. the Administrator may grant a waiver of compliance with a standard for a peiiod not exceeding 2 years from the effective date of such standard. Such waiver will be in writing and will: U) Identify the stationary source cov ci ed i2> Specify Die let mutation date of the waiver. The waiver may be termi nated at an earlier date If the conditions specified ur.der pai agraph (b) (3) of this section are not met. <3> Specify l >tcs by which steps to ward compliance are to be taken; and impose such additional conditions as the Administrator determines to be neces sary to assure installation of the neces sary controls within the waiver penod. and to assure protection of the health of persons during the waiver period. <c) Prior to denying any request for a waiver pursuant to tliis section, the Administrator will notify the owner or operator making such request of the Ad ministrator's intention to issue such denial, together with: <1> Notice of the Information and findings on which such intended denial is based. and (2) Notice of opportunity for such owner or operator to present, within such time limit as the Administrator specifies, additional information or argu ments to the Administrator prior to final action on such request. id) A final determination to deny any request for a waiver will be in writing and will set forth the specific grounds on which such denial is based. Such final determination will be made within 60 days after presentation of additional in formation or arguments, or GO days after the final date specified for such presen tation. if no presentation Is made. (e> The granting of a waiver unde, this section shall not abrogate the Ad ministrator's authority under section 114 of the act. waiver. Such cancellation will be made only after notice Is given to the owner or operator of the source. 61.I t Source leM auJ ruul> timl meth od*. (a) Methods 101. 102. and 104 In ap pendix B to this part shall be used for ali source tests required under this part, unless an equivalent method or an al ternative method has been approved by the Administrator. <b) Method 103 in appendix B to this part is hereby approved by the Admin istrator as an alternative method for sources subject to 61.32<a) and 5 6V.42 ib). (c> The Administrator may. after no tice to the owner or operator, withdraw approval of an alternative method granted under paragraphs (a), (b> or (d) of this section. Where the test results using an alternative method do not ade quately indicate whether a source is In compliance with a standard, the Ad ministrator may require the use of the reference method or its equivalent. (d) Method 105 in Appendix B to this part is hereby approved by the Adminis trator as an alternative method for sources subject to 61.52(b). | 40 IK 48292. October M, 1975, ^Ol.lo h v ailuliilii* of iifuruJi*oii.. 61.12 finl"ion Icsls and luon i t or i it c. fa) Emission tests and monitoring shall be conducted and reported as set forth in this part and appendix B to this part. (b) The owner or operator of a new source subject to this part, and at the request of the Administrator, the owner or operator of an existing source sub ject to this part, shall provide or cause to be provided, emission testing facili ties as follows: (1) Sampling ports adequate for test methods applicable to such source. 2) Safe sampling piatform(s). <3) Safe access to sampling platform(s). * (4) Utilities for sampling and testing equipment. 61.13 W.u' or of rm :vJon l ol *. (a) Emission tests may be waived upon written application to the Aummistjalor if. in his judgment., the xowice is meeting the standard, or d the sou: re is operating under a waiver of compliance or has requested a waiver of compliance <b> If application for waiver of the emission test Is made, such application shall accompany the information lequired by $61.10. The appropriate form is contained in appendix A to thus part. <c) Approval of any waiver granted pmsuant to this section shall not abro gate the Administrator's authority under the act or In any way prohibit the Ad ministrator from later canceling such T"he Availability to tho public of in formation provided to. or otherwise ob tained by. the Adnumstratoruuder this part shall be governed by Part 2 of this chapter. (4 1 I'U 36918. Sc |> i ember I, I 9761 61.16 Slate authority . (a) The provisions of this part shall not be construed in any manner to pre clude any State or political subdivision thereof from: (1) Adopting and enforcing any emis sion limiting regulation applicable to a stationary source, provided that such emission limiting regulation is not less stiingcnt than the standards prescribed under this part. (2) Requiring the owner or operator of a stationary source, other than a sta tionary source owned or operated by the United Stales, to obtain permits. licenses, or approvals prior to initiating construc tion. modification, or operation of such source. 61.17 Circumvention. No owner or operator subject to the provisions of this part shall build, erect, install, or use any article, machine, equipment, process, or method, the use of which conceals an emission which would 1022 76 Copy** ,M < 1976 by The Buieou of Notional Affairs, Inc. UCC 01 7305 [Sec. 61.171 S FEDERAL REGULATIONS ^crwisc constitute a violation of an tural members are wrecked or taken out The deposition of asbestos tailings or as applicable standard. Such concealment arc excluded. bestos-containing was to on roadways includes, but is not limited to, the use of (n) "Planned renovation*' means a covered with snow or Ice is considered gaseous dllut-ants to achieve compliance renovation operation, or a number of "surfacing." with a visible emissions standard, and sue)] operations, In which the amount (c) Manufacturing: There shall be no the piecemeal carrying out of an opera of friable asbestos material that will be visible emissions to the outside air. ex tion to avoid coverage by a standard that removed or stripped within a given pe cept as provided in paragraph (f) of this applies only to operations larger than a riod of time can be predicted. Operations section, from any of the follow'ing op specified size. that are individually non-schcduled are erations If they use commercial asbestos [40 FR 48291Qc1oN.t 14. 19751 Subpart B--National Emission Standard \ for Asbestos j. 61 .20 ApplTcnbiiily. " The provisions of this subpart .are ap plicable to those sources specified in 5 61 22. 61.21 Definitions. Terms used in this subpart are defined in the act. in subpart A of this part, or in this section as follows: (a) "Asbestos'* means aclinolite. amositc. anlhophylhte, chrysotile, crocidolile, tremolite. <r>) "Asbestos material*' means asbesios or any material containing as bestos. (c) "Particulate asbestos material'' means finely divided particles of asbestos material. '<]> "Asbestos tailings" means any solid waste product of asbestos mining or included, provided a number of such op or from any building or structure in erations can be predicted to occur during which such operations are conducted. a given period of time based on operating experience. (o) "Emergency renovation*' means a renovation operation that results from a sudden, unexpected event, and Is not a planned renovation. Operations necessi tated by non-routino failures of equip ment arc Included. (p) "Adequately wetted" means suf ficiently mixed or coated with water or an aqueous solution to prevent dust emissions. (q) "Removing" means taking out fri able asbestos materials used to insulate or fireproof any pipe. duct, boiler, tank, reactor, turbine, furnace, or structural member from any building, structure, facility, or installation. (r) "Stripping" means taking o/T fri able asbestos materials used for insula [40 FR 48292. October 14. 1 975( (1) The manufacture of cloth, cord, wicks, tubing, tape, twine, rope, thread, yarn, roving, lap, or other textile ma terials. (2) The manufacture of cement prod ucts i3> The manufacture of fireproofing and insulating materials. (4) The manufacture of friction products. <5> The manufacture of paper, mill- board. and felt. <G> The manufacture of floor tile.\ (7) The manufacture of paints, coat ings. caulks, adhesives, sealants. <8) The manufacture of plastics and rubber materials. 9> The manufacture of chlorine. tion or fireproofing from any pipe. duct, (10) The manufacture of shotgun boiler, tank, reactor, turbine, furnace, shells. or structural member. (11) The manufacture of asphalt con milling operations which contains as bestos. :e> "Outside air" means the air out side hmkhnes and structures. <f "Visible emissions" means any emissions which arc visually detectable (s) "Fabricating'* means any process crete. ing of a manufactured product contain (d> Demolition and renovation: Jfoe ing commercial asbestos, with the ex requirements of this paragraph shall ception of processing at temporary siiejf^rrppTy to any owner or operator of a for the construction or restoration cf renovation operation who buildings, structures, facilities or instal intends to demolish any InstitutionaT without the aid of instruments and which lations. rpuiiiTcTcial, or industrial building (in contain particulate asbestos material. <t) "Inactive waste disposal site" cluding apartment buildings having more (g) "Asbestos mill" means any facility engaged in the conversion or any Inter mediate Step in the conversion of asbestos ore into commercial asbestos. Outside storage of asbestos materials Is not con sidered a part of such facility. (h) "Commercial asbestos" means any variety of asbestos which Is produced by extracting asbestos from asbestos ore. U) "Manufacturing" means Ihe com bining of commercial asbestos, or in the case of woven friction products the com bining of textiles containing commercial nsbenos, with any other mntcrlal(s). In cluding commercial asbestos, and the processing of this combination Into a product as sDrrjfird in 5 Gl.22(c) (j> "Demolition" means the wiccking or taking out of any load-supporting structural member amt any related re moving or stripping of friable asbestos materials. (k) "Friable asbestos material" means any material that contains more than 1 percent asbestos by weight and that can be cmmblcd, pulverized, or reduced to powder, when dry, by hand pi ensure. "Control device asbestos waste'' means any asbestos-containing waste material that is collected in a pollution control device. <m) "Renovation" means the remov ing or stripping of friable asbestos mate ria! used to insulate or fireproof any pipe. duct, boiler, lank, reactor, turbine, furnace, or structural member. Opera means any disposal site or portion thereof where additional asbestos-con taining waste material will not be depos ited and where the surface is not dis turbed by vehicular traffic. (u) "Active waste disposal site" means any disposal site other than an Inactive site. (v> "Roadways" means surfaces on whichil miiiuowtoir vvechiiiivc-liecsj turaavne.il ijniLculuiudninibg. but not limited to. highways, roads. streets, parking areas, and driveways. (w) "Asbestos-containing waste mate rial" means any waste which contains commercial asbestos and is generated by a source subject to the provisions of this subpart, including nsbestos mill tailings, control device asbestos waste, friable as bestos waste material, and bags or con tainers Mint previously contained com mercial asbestos. (40 I K 48292. Oclnltcr 14. 1 975] 61.22 Fmbsiim Miin<Lril. (a) Asbestos mills: There shall be no \isiblc emissions to the outside air from any asbestos mill except as provided In paragraph (f) of this section [39 1 K 15936. May 3. I 974J (b) Rnodu-ays: The Mtrlacinp of road ways with asbestos tjihnps or with .ishc\tos-con!atmn wnstc that is LWiKinted by any source swbtect lo p;ir:i^r.iplis fc). (d). (e) or (li). of this section is prohibited, except for temporary road than four dwelling units), structure, facility. Installation, or portion thereof which contains any pipe. duct, boiler, tank, reactor, turbine, furnace, or struc tural member that is Insulated or fire proofed with friable asbestos material, except as provided in paragraph (d)(1) of this section: or who Intends (ft renn*- any institutional, communal nr du--s--t-n---a--l---b--u---il-d---i-n- g---,---s--t-ructure. facilsi-ty, insSrHfrHon. or portion thereof wncre more than 80 meters (ca. 2G0 feet) of pipe in sulated or fireproofed with friable as bestos material arc stripped or removed, or more than 15 square meters (ca. 160 square feet) of friable asbestos material used to insulate or fireproof any duct, boiler, tank, reactor, turbine, furnace, or structural member are stripped or re moved. (])(i) The owner or operator of a demolition operation is exempted from the requirements of tins paragraph pro vided. (1) the amount of friable asbestos material in the building or portion thereof to be demolished is less than 80 meters (ca. 260 feet) used to insulate pipes, nnd less than 15 square meters (ca. 160 square feet) used to insulate or fire proof auy duct, boiler, tank, reactor, tur bine, furnace, or structural member, and (2) the notification requirements of par agraph (d)(1) (il) are met. (ii) Written notification shall be post marked or delivered to the Administrator at least 20 days prior to commencement of demolition and shall include the In tions in which load-supporting struc ways on an area of asbestos ore deposits. formation required by paragraph (d) (2) nonmtni RepoUer UCC 017306 ISec. 61 22(d)(11 In) I H AZARDOUS emissions 1 . tKlO of this section, with the exception of the i4i The fi 'owing prrccduica shall lie ground level, except lho--o materials rc- information required bv paragraphs used to picvr :t emissions of particulate inovcfVj** .unit;, U_iirjgeVnons._shaTl be (2) (iii), (vi). (vi>, (vui). and fix), and asbestos material to outside air: TVaiisJ>oiTed^tojJic ground via dustlti^ht shall .state IJic jncajured or estimated hi JYinble nsbrsio.s materials, \r-cd chutes or`containers. amount of friable asbestos material used for insulation and fireproofing which is present. Techniques of estimation shall be explained. lo insulate or fireproof nnv pipe. duct, boiler. Lank, reactor, Lubinc. furnace, or structural member, shall be icmovcd fvi> Except as specified below._lhc wet ting reonurments of tins paragraph are suspended when the temperature afTlic' prmt or~we~LliiTg~rs ljeiOW d'l? fjZT'l . (2) Written notice of intention to de-^ ^wnciwilame asbestos materials are not molish or renovate shall be provided to the-Administrator by the owner or opera`s "IMiv portion of tor of the demolition or renovation oper ation. Such notice shall be postmarked ' _____ facility, or in- u'iTfllE or deliveredlo the Administrator atleast able asbestos materials and before lo"gays pnor Ifl conirucnrcmeiil pf demo- avrcckmg or dismantling of any other > htinn ftr ^ Anrlv as nnssible prior to pnrrTop J ~n f ' ksiuihh qinTT-~;Lr; urtrrfe. I commencement of emergency d^HTDIfllliu facility, or installation that would pre \ silPjccTTo paragraph (d)(6) of this sec- clude access to such materials for sub j tidlj. ntid as early as possible prior to sequent removal. Removal of friable asbestos materials used for insulation | he e* shall-jnciu^e tne i oiiowjhg informa- or fueproofing of any pipe. duct, or wetted due to freezing temperatures, such materials on pipes, ducts, boilers, tank^T reactors, turbines, furnaces, or structural members shall, to the maximum extent vossibic, btrrpmpvcfl ::s nnrcrsrrn sclttong pt'iorTo wrecking- In no caseThnTi fh5`TtTfliirY)icnlsoi paragraphs (d> (4) (iv) or (d)(4Hv> be suspended due to freezing temperatures. (vii) For renovation operations, local exhaust ventilation and collection sys lutin: structural member which are encased in tems may be used, instead of wetting as HName of owner or operator. K^(ii) Address of owner or operator. concrete or other similar structural ma specified in paragraph <d) (4 ) (li). to pi cterial is not required prior to demoli vent emissions of particulate asbestos <iii) Description of the building, struc ture. facility, or installation to be de molished or renovated, including the size, age, and pnor use of the structure, and the approximate amount of friable asbestos material used for insulation and fireproofing. riv Address or location of the build ing, structure, facility, or installation. W' (v) Scheduled starting and comple tion dates of demolition or renovation, v/ (vii Nature of planned demolition or renovation and method(s) to be em ployed. <vii> Procedures to be employed to meet the requirements of this paragraph -and paragraph O' of this section. * (viii> The name and address or loca tion of the waste disposal site where the tion. but such material shah be arie- _qunLrly ~welted whenever exposed dur ing demolition. (ih Friable asbestos :na.t/u :qls used to insulate or Tircnrpof_" ibncsV ducts. boners, tanks, rcii ii'ihr'L-.fju'- nacos,_ or hsTrnrtnral members shall be adcquatelv veileel ciunna's'liimne. ex- ~ccpx'aspi-ovideefTn paragraphs 'cfTctr (iv), cd> 14> tvi> or cd) <4> fvuJ of this section. (in) Pipes, ducts, boilers, tanks, re actors. turbines, furnaces, or structural members that are insulated or fire proofed with friable asbestos materials may be taken out of anv building, struc ture. facility, or installation subject to this paragraph as units or in sections provided the friable asbestos materials material to outside air when damage to rrmoment resulting from the wetting would be unavoidable. Upon request and supply of adequate informaiion~TntT'Admi'uslto tcr~w.il 1. d c [cr mi nc \\V)cU\cT <1 am - jvj cj^o, eouipmentires.1111 nIXfonTwcttfhg to comply with the provisions ortlusITar';i.;V,y'll_yoT^rr^5c"unaiolffal)IgT ^TTdfioc51 exhaust ventilation systems shall be de signed and operated to capture the asbes tos particulate matter produced by the stripping and removal of friable asbestos material. There shall be no visible emis sions to the outside air from such local exhaust ventilation and collection sys tems. except as provided in paragraph ' f i of this section. <3> Sources subject to tins paragraph arc exempt from the requirements of friable asbestos waste will be deposited, r (ix> Name, title, and authority of the State or local governmental representa tive who has ordered a demolition which is subject to paragraph (d)<6) of tins section. (3)<i) For purposes of determining whether a planned icnovntmg operation constitutes a renovation within the meaning of this paragraph, the amount of friable asbestos material to be re moved or stripped shall be: (A) For planned renovating opera tions involving individually non-scheduJed operations, tlie additive amount of friable asbestos material that can be pre dicted will be removed or stnpped t a ouitc over the maximum period of time for winrh a prediction can be made. The pound snail be not less than 30 days and not longer (nan one year. exposed during cutting or disjointing arc 5$ Ol.Ofxa). 61.07, and 61.00. adcouatcly wetted during the cutting 6> The demolition of a building, struc- or disjointing operation. Such units luie. facility, or installation, pursuant to shall not be drorped or thrown lo The an order of an authorized rcpie^entalivc ground, nut shall be careimiy lowered of a State or local governmental agency, to ground Icvct. is'ued because that building is slruclur- 'iv The stripping of friable asbestos niaterials`"usCQ Ju liisuii,.ie"Of~nTe't)rnoI "TCny J51p6. ducT.' Boiler, tank," re a c tor 7 tTj r bine, furnace, or structural member that allv unsound and in danger of imminent collapse is exempt from all but the fol lowing requirements of paragraph <d> of this section: has been rernoved as a unit or ;n sections .vUftTo'VTnea irTparagraph 'd)(4)iiif) of this section shall be performed in ac cordance with pTnTrrrnim"'7(lTTlT(,rn" of TTuf.^rtTOfi-'RnTlTcr'TVdfi^'rb'hTFir' s\ I77i the welling req i nr cm ent^.Tlor.m cTfli^Tist Vc n l fi a t i o n aiuT cm Tee l <lc rtf'm a y < i The notification : cquircmcnls spec ified by para gra ph (d)(2) of tins section: mi The requirements on stripping of friable asbestos materials from previously removed units or sections as specified in pamgranh (dM4i hvi of this section; be usetTTo prevent enusslons Co Oaf^oilT- tiii) The welling as specified by para- srclc*'aiTrFu7rh~local exha-ut'vc :!nT13Yr~ graph (d><4)(v> of tins section, of fr;- FT*ferns shall be desunied ar.n XTIT'TFTed able asbestos materials that have been U5~eapLifeline"asbestos pTrtieu!ate mat- removed or stripped; fen:>'rffc I(XT c'<rtn--rhr rr:; :;nr'T~n>* "T* ruble <iv The portion of the structure bring B> For each planned renovating op eration not covered by paragraph fd)(3) A), the total amount of friable as ashes Cos' `'"i n a CeTTaT'" T11 cm''c' "F i a 11 be no Tisnur einisMOns' to the outside air from oin7 Wnl^rvi:dT7<;I_vpnt d:U :nn and col demolished that contains fnablc asbest os mate; ials all be adequately wetted dm mg Uic wreck :ig operation. bestos material that ran be predicted will be removed or stripped at a source. (iii For purposes of determining whether an emergency renovating op eration constitutes a renovation within the meaning of this paragraph, the lection 'systems excerpt"-as pjoviticd in pai-agrnph <f> of this section. <v** All fnablc asbestos mafcrvals that !ia\'C been rcniovrd or s11iu>cd shall be adequately wetted lo ensure that such materials remain wet duYine nil rcmaiihr f T9 ; J< 1 i936. U i/ y 3. } 974. 40 l R 4H. 92 Oci'dicr 1 4. I 975f (c ' Spraying : Tlt^re c)ialt be no \ iiable cnh'Sions to the outclde air from the spray-on application of materials con taining more than 1 percent asbestos, on amount of friable asbestos material to iiTg~~sTagcs of urmnnrrph or renovarfon\ a dry weight basis, used to insulate be removed or stripped shall be the total and related handling operations, '^uch \fircproof equij>ment and machinery, c.x- amount of friable asbestos material that irmlcrials shall not be dropped or thrown fcept as provided in paragraph (f) of this will be removed or stripped as a result to (he ground or a lower floor. Such ma- section. Spray-on materials used to ni'a- of the sudden, unexpected event that tcrmls that have been removed or )nt.e or fireproof buildings, stria tuies. necessitated the tenovation. sTnpped.,,n^ovc pipes, and conduits shall contain less 1 -) 6- 7G Copy*>ghl 'V97^6^by TKr Buirau ol Nol'onal Aito'st lr>c. | Sec. 61.22(el| UCC 01 7307 i IULHAL iitGULAi IONS j percent asbestos on a dry uciclit waste mntch.il which is generated by any asbestos-containing waste mate such source. rial which is generated by such source. ~ sources subject to this paragraph Mc` cscinnt- -f-ro--m the. - r-e-q-u-irements ol r.i ostal. S 61.07, and 5 61 09. <2) Any owner or operator who in tends to spray asbestos materials which contain more than 1 percent asbestos on a dry weight basis to Insulate or fireproof equipment and machinery shall report such intention to the Administrator at least 20 days prior to the commencement of the spraying operation. Such report shall include the following information: ] 40 1 R 48292. October 14. 1975J (i) Name of owner or operator. < ii > Address of owner or operator, till) Location of spraying operation. <iv) Proccduies to be followed to meet the requirements of this paragraph. (fi Rather than meet the no-visibleemission requirements as specified by paragraphs * a), <c>, (d>, (e). <h). (j). and ik> of this section, an owner or op erator may cicct to use Uic methods spec ified by $ 61.23 to clean emissions con taining particulate asbestos material be fore such emissions escape to. or are vented to. the outside aux <g i Where the presence of uncombined water is the sole reason for failure to meet the no-visiblc-emission require ment of paragraphs (a), (c>, (d), (e>. <h> < j). or (k) of tins section, such fail ure shall not be a violation of such emis sion requirements. (hi Fnbiicnting: There shall be no visible emissions to the outside air. ex cept as provided in paragraph <0 of this section, from any of the following op erations if they use commercial asbestos or Vom any building or structure in which such operations are conducted. <1) Tiie fabrication of cement building products. <2) Tiie fabrication of friction prod ucts. except those operations that pri marily install asbestos friction materials on motor vehicles. <3' Tiie fabrication ol cement or sili cate bomd for ventilation hoods; ovens; clectncal panels: laboratory furniture; bulkheads, partitions and ceilings for marine construction; and flow control devices for the molten metal industry. (p Insulating: Molded insulating ma terials which arc friable and wet-applied insulating materials winch arc friable after dr;, mg. installed after the effective date of these regulations, shall contain <2) All asbestos-containing waste ma terial shall be deposited at waste dis posal sites which are operated in accord ance with the provisions of 5 01.25. (3) Rather than meet the requirement of paragraph (j)(l) of this section, an owner or operator may elect to use either of the disposal methods specified under ())<3>(i) and (ii) of this section, or an alternative disposal method which has received prior approval by the Ad ministrator; (i) Treatment of asbestos-containing waste material with water: (A) Control device asbestos waste shall be thoroughly mixed with water into a slurry and other asbestos-containing waste material shall be adequately wetted. There shall be no visible emis sions to the outside air from the collec tion. mixing and wetting operations, ex cept as provided m paragraph (f) of this section. <B> After welting, all asbestos-con taining waste material shall be sealed into leak-tight containers while wet. and such containers shall be deposited at waste disposal sites which arc operated in accordance with the provisions of 61.25. (C) The containers specified under paragraph shall be labeled with a warning label that states: Caution Contains Asbestos Avoid Opening or Breaking Container Breathing Asbestos is Hazardous to Your Health Alternatively, warning labels specified by Occupational Safety and Health Standards of the Department of Labor, Occupational Safety and Health Admin istration (GSHA) under 29 CFR 1910.93a(g) (2) (ii> may be used. <ti) Processing of asbestos-containing waste material Into non-fnnblc forms: fA AU asbestos-containing waste material shall be formed into non-*nable pellets or other'shapes and deposited at waste disposal sites which are operated in accordance with the provisions of 5 Cl 25. < 3) *T1 icre shall be no visible emis sions to the outside air from the collec tion and pioccssinc of asbrncscontninmg waste material, except as i2> All asbestos-containing waste ma terial shall be deposited at waste disposal sites which are operated In ac cordance with the provisions of 5 61.25. (3) Rather than meet the requirement of paragraph (k)<l> of this section, an owner or operator may elect to meet the following requirements in para graphs (k)(3) (R and (ii). or use an alternative disposal method which has received prior approval by the Admin istrator; u) There shall be no visible emissions to the outside air from the transfer of control device asbestos waste to the tailings conveyor, except ns provided in paingrnph (f) of this section. Such waste shall be subsequently processed cither as specified in paragraph ik)<3)t|i> of Jus section or as specified m paragraph ij> <3) of this section. uR All asbestos-containing waste m n l c m aTsh retrbe"TdctjUa C^TTTTfiVc<T~Tt- i t h aw\vctt!ng agent recommended by' uie iTyroufricuiVemr the a gc n trto~c ftey T &rJP?t^ng^i7ingsTpri6r^^dyppsni<iii Tt a^w'n~ste^<TTM>osnT mVc. STiclf agent'shall b'JTrRM11 irrtoin m ended for the partic ular dust by the manufacturer of the agent. There shall be no discharge of visible emissions to the outside air from tiie wetting operation except as specified in paragraph (f) of this section. Wetting may be suspended when`the ambient temperature at the waste disposal site is less than -- 9 5*C fen. 15'F). The ambient air temperature shall be determined by an appropriate measurement method with an accuracy of tl*C (2 Fi and vecoided at least at hourly intervals dur ing the period that the operation of the wetting system is suspended. Records ol such temperature measurements shall be retained at the source for a minimum of wo years and made available for inspcct'on by the Administrator. R< The owner of any inactive waste disposal site, which was operated by soui ccs covered under t 61.22 < a >, (c> or <hl and where asbestos-containing waste material produced by such sources was deposited, shall meet the following stn ndards: (l There sjial) be.no vis fide cfmss ions to the outside air from an inactive waste disposal site subject to this paragraph, except as provided in paragraph (li (5) of this section. no commercial asbestos. The provisions specified in pnrapraph < f) of this see.ion. < 2' Warning signs sha 11 be displayed of tins paragraph do not apply to insu (4) For the purposes of this pnrn- a' all entrances" -fird. ajong^ fiic i^i'oi^riy lating materials whirl) are spi ay applied; ptaph ip. the term all asbestos-con TTuWorTIu^^ilo '.qe-along die perimeter of such mntenals me jcgulatcd under taining waste material ns applied to Inc scetionsjofJ.Uc^suc_\wcr.c rTsb'cslos^ 5 61 22>e>. demolition and renovation operations 7V,hlaimnn waste material wns^lcpusilccT. (}> Waste disposal /or manufacturing, covered by paragraph id) of Dus sec hTtrTiTTPi'vals ot 1O0 m lea. 330 ft>or less. fabi irat.mg. demolition, renovation and tion includes only friable asbestos waste VfiTccj>T"hs Vpccificd m paragraph (1)(.4) spiaying operations: The owner or op and control device asbestos waste. of tins section Signs shall be posted in erator of any source covered under the <k) Waste disposal for asbestos nulls: such a manner and location that a person provisions of paragraphs (c>. (d). (c>. The owner or operator of any source may easily i cud Die legend. The warning or (h) cf this section shall meet the fol covered under the provisions of para ;igns rcqmied by this paragraph shall lowing standards: graph (a> of this section shall meet the conform to the requirements of 20" x 14" (1) The!c shall be no visible emissions following standard: upright-format signs specified in 29 CFR to the outside air. except as piovided in (1) There shall be no visible emis 1010.145(d)(4) and this paragraph. The pm a graph (jM3> of this section, dur sions to the outside air, except as pro signs shall display the following legend ing the collection; processing, including vided in paragraph < k) (3) of this section, in tiie lower panel, with letter sizes and incineration; packaging; transporting; during the collection, processing, pack styles of a visibility at least equal to those or deposition of tiny nsbcsLos-containing aging. transporting or deposition of specified in this paragraph. fivnonn>nl Repo'Uf I See. 6) 22(1)1211 8G UCC 0)7308 HAZARDOUS EMISSIONS S-283 121:0467 LF.CENO AbOL.sTOS Waste Dtsrosxi. She Do Not Create Dust Breathing Asbestos 5s Hazardous to Your Health Notation 1" Sans Serif, Gothic or Block Sans Serif. Gothic or Block 14 Point Gothic Spacing between lines shall be at least equal to the height of the upper of the two lines. <3> The perimeter of the site shall be fenced in a manner adequate to deter access by the general public, except as specified in paragraph (1) (4> of this sec tion. (4) Warning signs and fencing are not required where the requirements of paragraphs (1)<5> (0 or (ii) of this sec tion are met. or where a natural barrier adequately deters access by the general public. Upon request and supply of ap propriate information, the Adminis-. tralor will determine whether a fence or a natural barrier adequately deters ac cess to the general public. (5) Rather than meet the requirement, of paragraph < 1) (1) of this section an owner may elect to meet the require ments of this paragraph or may use an alternative control method for emissions from inactive waste disposal sites which lias received prior approval by the Administrator. (i) The asbestos-containing waste material shall be covered with at least 15 centimeters fca. 6 inches) of com pacted non-asbcstos-con taming mate rial, and a cover of vegetation shall be grown and maintained on the area ade quate to prevent exposure of the asbes tos-containing waste material; or <ii> The asbestos-containing waste material shall be covered with at least GO centimeters <ca. 2 feet) of compacted non-nsbcstos-coiUaining material and maintained to prevent exposure of the asbcstos-coniainmg 'vaste; or fin) For inactive waste disposal sites (or asbestos tailings, a resinous or petro leum -based dust suppression agent which effectively binds dust and controls wird erosion shall be applied. Sue!) agent shall be used as recommended for the partic ular asbestos tailings by the dust supPics'ion agent manufacturer. Other equally clTcclivc dust suppression agents may be used upon prior approval by the Administrator. Tor purposes of this para graph. waste crankcase oil is not con sidered a dust suppression agent. [4<J l R 4R202. October 14. 1 97 51 SGI.23 Air-i If nlr-rlc.anjpg is elected, as pm-mitlc.. by 5 5 61 22 < f) and G1 22<d) f 4 Miv). the requirements of this section must be met. 140 1 R 48:91 Odolvr 14. 19751 fa) Fabric filler collection devices mdst be used, except as noted in para graphs fb) and (c) of this section. Such devices must be operated at a picssurc di op of no more than 4 inches water gage as measured aciov; the filter fabric. The an flow permeability, as dctcimined byl ASJM method 0737-69. must not exceed 30 ft'/mm/ft* for woven fabrics or 35 ftVn\in/ft: for felled fabrics, except that 40 ft*/min/ft` for woven and 45 ft*/ niin/ft' for felted fabrics is allowed for filtering air from n-sbestos ore dryers. Each square yard of felted fabric must weigh at least 14 ounces and be at least one-sixteenth inch thick throughout. Synthetic fabrics must not contain fill yarn other than that which Is spun. fb) If the use of fabric filters creates a fire or explosion hazard, the adminis trator may authorize the use of wet col lectors designed to operate with a unit contacting energy of at least 40 inches water gage pressure. (c) The administrator may authorize the use of filtering equipment other than that described in paragraphs a) and fb) of this section if the owner or operator demonstrates to the satisfaction of the administrator that the filtering of par ticulate asbestos material is equivalent to that of the described equipment. 'd) All air-cleaning equipment au thorized by this section must be properly installed, used, operated, and maintained. Bypass devices may be used only during upset or emergency conditions and then only for so long as it takes to shut down the operation generating the particulate asbestos material. 6 1.2 1 Hciiorimg. The owner or operator of any existing source to which this subpart is applicable shall, within 90 days after the effective date, provide the following mfoimotion to the administrator: <a> A description of the emission con trol equipment used for each process; <b> If a fabric filter device is used to control emissions, the pressure drop across the fabric filter in inches water gage. (1) If the fabric filter device utilizes a woven fabric, the airflow permeability m ft'/mm/ft*; and. if the fabric is syn thetic. indicate whether the fill yarn is spun or not spun. (2) If the fabric filter device utilizes a felted fabric, the density m oz/yd*. the minimum thickness in inches, and the airflow permeability in U'/min/ft'. (c) For sources subject to 61.22<j) and 61.2200 ; (1) A brief description of each process that generates asbcstos-contannng waste material. (2) The average weight of asbestoreoiilnining waste matcual disposed of. measured In kg/day. <3> The emission control methou* used in all stages of waste disposal. (4) The type of disposal site or incin eration site used for ultimate disposal, the name of the site opciator, an-i the name and location of the disposal site <d) For sources subject to 5 61.2211 ^: f I > A brief description of the sue. <2> The method or methods u.sea io comply with the standard, or alternative procedures to be used. fe Such information shall accom pany the information requned by G1 JO. The information described in this section shall be reported using the format of Appendix A of this part. 140 1R 48292. October 14. 1975 61.25 W.nMc Ui>po>ul Mir*. I# order to be an acceptable site for disposal of asbestos-containing waste material under 61.22 (j) and (k). an active waste disposal site shall meet the requirements of this section. (a) There shall be no visible emissions to the outside air from any active wa>t* disposal site where asbestos-containing waste material has been deposited, except as provided in paragraph (e) of t'v.r section. (b) Warning signs shall be displayed at all entrances, and along the propeitv line of tiie site or along the perimeter of tiie sections of the site where asbestoscontaining waste material us deposited at intervals of 100 m tea. 330 ft) or 1c*'cxrcpt as specified in paragraph id) ol tin* section. Signs shall be posted in such a manner and location that a person may easily read the legend. The warning signs required by this paragraph slv.ll conform to the requirements of 20" x 14" upright formH signs specified in 20 Cl 71 1310.H5<d) ` 4 > and thri paragraph. The signs 'hall display the fallowing legend in the lower pane!, with letter sizes and styles of a visibility at lean equal to those specified in this paragraph. Asorsres Waste Disrr>s\i. Site Do Not Create Dust Erenthing Asbcs'os Is Hazardous to Your Hcalih Notation l" Sans Serif. Gothic or Block Sans Serif. Gothic or Block 14 Pont Got'ilr. Spacing between hue* shall be at least equal to the height of the upper of the two lines. <c> The perimeter of the disposal site shall be fenced in order to adequately deter access to the general public except .os .specified in paragraph (d) of tins section. (d) Warning signs and fencing are not required where the requirements of paragraph (e)(1) of tins section r.ic met. or where a natural barrier ade quately deters access to the general public. Upon request and supply of nni.roprialc information, the Administra tor will determine whether a fence or a natural barrier adequately deters access to the general public. (e> Rather than meet the lequnci lent of paragraph (a) of tins section, an owner or operator may elect to meet the ic.pmcmcnt*. of paragraph (cMl) or 'e) O of this section, or may use an al ternative control method for emissions from active waste disposal sites which has received pnor appioval by the Administrator. U) At the end of each operating dr.v. or at least once every 21-hour -period while the site is in continuous operation, the asbestos-containing waste material which was deposited at the site during the operating day or previous 24-hour period shall be covered will: al least 15 ccnrimcters (ca G inch.cs) of compacted r.on-asbcs tos -containing material. l 1G 76 Copy'*qhi 1976 by The Bo'f Oy of No'tonol Allon UCC 017309 isee. 6i.25(cinn 87 0^68 FEDERAL REGULATIONS <2> At the end of each operating clay, or at least once every 24-hour period while the disposal site is In continuous operation, the asbestos-containing waste material which was deposited at the site during the operating day or previous 24hour period shall be covered with a res inous or petroleum-based dust suppres sion agent which effectively binds dust and controls wind erosion. Such agent shall be used as recommended for the particular dust by the dust suppression agent manufacturer. Other equally ef fective dust suppression agents may be used upon prior approval by the Admin istrator. Tor purposes of this paragraph, waste crankcase oil is not considered a dust suppression agent. (j> "Eetylhum alloy" means any metal to which beryllium has been added in order to increase its beryllium content and which contains more than 0.1 per cent beryllium by weight. (k) "Propellant plant" means any facility engaged in the mixing, casting, or machining of propellant. 61.32 Enns-fion standard. fa) Emissions to the atmosphere from stationary sources subject to the provi sions of this subpart shall not exceed 10 grams of beryllium over a 24-hour period, except as provided in paragraph fb) of tlxis section. (b) Rather than meet the require amt the corresponding 30-day average ber> Ilium concentrations. (2) Within 60 days after receiving such report, the Administrator will notify the owner or operator in writing whether approval is granted or denied. Prior to denying approval to comply with the pro visions of paragraph <b) of this section, the Administrator will consult with representatives of the stationary source for winch the demonstration report was submitted. (c) The burning of beryllium and/or beryllium-containing waste, except pro pellants. is prohibited except m incinera tors. emissions from which must comply with the standard. 61.3.3 Stark <nm|>lmZ* t- 140 I'R 48292. Ociobcr 14. Subpart C--National Emission Standard for Beryllium 61.30 Applicability. The provisions of this subpart are ap plicable to the following stationary sources: (&) Extraction plans, ceramic plants, foundries, incinerators, and piopciiant plants winch process beryllium ore. beryl lium. beryllium oxide, beryllium alloys, or beryllium-containing waste. ib> Machine shops which process beryllium. brryiJium oxides, or any alloy when such alloy contains more than 5 percent beryllium by weight. 61.31 fVfinilimis. Terms used in this subpart are de fined in the act. in subpart A of this part, or m tlus section as follows: <a> "Beryllium" means the element bciTllium. Where weights or concentra tions arc specified, such weights or con centrations apply to beryllium only, excluding'the weight or concentration of any associated elements, (b) "Extraction plant" means a fa cility chemically processing beryllium ore to beryllium metal, alloy, or oxide, or performing any of the intermediate ment of paragraph fa) of this section, an owner or operator may request ap proval from the Administrator to meet an ambient concentration limit on beryl lium in the vicinity of the stationary source of 0 01 averaged over a 30-day period. (l) Approval of such requests may be granted by the Administrator provided that; fi) At least 3 years of data Is avail able which in the judgment of the Ad ministrator demonstrates that the fu ture ambient concentrations of beryllium in the vicinity of the .stationary source will not exceed 0.01 /ig/m', averaged over a 30-day penod. Such 3-year period shall be the 3 years ending 30 days before the effective date of this standard. <in The owner or operator requests such approval in writing witlun 30 days after the effective date of this standard. fui> The owner or operator submits a report to the Administrator within 45 days after the effective date of this standard which report Includes the fol lowing information: (a) Description of sampling method Including the method and frequency of calibration. <b) Method of sample analysis. (c> Averaging technique for determin ing 10-day average concentrations. (a) Unless a waiver of emission testing Is obtained under 61 13, each owner or operator required to comply with j 61.32(a) shall test emissions from his source. (1) Within DO days of the effective date in the case of an existing source or a new source which has an initial startup date preceding the effective dale; or (2) Within 90 days oi startup in the case of a new source which did not have an initial startup date preceding the ef fective date. <b) The Administrator shall be noti fied at least 30 days prior to an emission test so that he may at his option observe the test. f c) Samples shall be taken over such a period or periods as arc necessary to ac curately determine the maximum emis sions which will occur in any 24-hour period. Where emissions depend upon the relative frequency of operation of differ ent types of processes, operating hours, operating capacities, or other factors, the calculation of maximum 24-hourperiod emissions wj)| be based on that combination of factors which is likely to occur during the subject period and which result in the maximum emissions. No changes In the operation shall be made, which would potentially increase emissions above that determined by the steps in these processes. <c> "Beryllium ore" means any nalu- rallv occurring material mined or gatheird for its beryllium content. <d> "Machine shop" means a facility pci forming cutting, grinding. t-urning. honing, nulling, rie ournng. lapping, clact rochcmieal machining, etching, or other Miminr opetations e' "Ceramic plant" means a mnnufnc'unng plant producing ceramic items. if' "Roundiy" means a facility en gaged in the melting or casting of bC'.Alhum nu'lul or ahoy. " Bci \ 11 mm-coih amine waste" means material contaminated with be: yIImm and -or bet ylhum compounds used or generated during any process or operation performed by a souicc subject to ihis subj>arl. (h> `'Incinerator'' means any furnace met! in the process of burning waste for the piimary purpose of reducing the volume of the waste by removing com bustible matter. m ) "Propel!ant" means a fuel and oxi- dh'cr physically or chemically combined which undergoes combustion to provide roc Viet propulsion. (d) Number, identity, and location (address, coordinates, or distance and heading from plant) of sampling sites. (e> Ground elevations and height above giound of sampling inlets. Plant and sampling area plots showing emission points ar.d sampling sites. Topographic features .significantly a (Tcrling dispersion including plant budding heights and locations .-.hall be iiu lulled. 'O inf"! motion necC'Saiy for esti mating dr-per si on including -iac k height. iiMdc diameter, exit gas temporal tire. e\it -.clocitv or flow rate, and beryllium conccntrat PH. i A dcsciiption of data and procc- du:'\; (methods or models) used in dc<u:n the rr sampling network <i c . num ber and location of sampling sites) (i) Air sampling data indicating beryl lium concent:ations in the vicinity of the stationary source for the 3-year period specified in paragraph (bun of this section. This data shall be piescnled chi onnlogically and include the beryl lium concentration and location of each, individual sample taken by the network most recent source test, until a new emis sion level has been estimated by calcula tion and the results reported to the Ad ministrator. 'tU All samples shall be analyzed and beryllium emissions shall be determined within 30 days after the source test. All determinations shall be reported to the Administrator by a registered letter dis patched before the close of the next businc'i day following such determination. 'e) Records of emission test results and oilier data needed to detci mine total cmisMons shall be retained at the source and made available, for inspection by the Administrator, for a minimum of 2 years. 61.3 4 Air sampling. a' Stationary sources subject to G1 32<b shall locate air sampling sites In accordance with a plan approved by the Administrator. Such sites shall be loealed in such a manner as is calculated to detect maximum concentrations of bery lhum in the ambient air. <b> All monitoring sites shall be op erated continuously except for a rcasonablc time allowance for instrument main tenance and calibration, for changing E nvi ronmf n 1 Reporter (Sec. 61.341b)) qq UCC 017310