Document 4a80MEnB7BZ1YMaqzQq7LO7r1
10
23. Circulating Chilled or Hot Water Return
24. Make-Up Water 25. Humidification line 28. Drain 27. Brine Supply 28. Brine Return
rtwthg
29. Soil, Waste, or Leader (Above Grade)
. 30. Soil, Waste, or leader (Below Grade)
31. Vent 32. Cold Water 33. Hot Water 34. Hot Water Return 35. Fire line 38. Gas 37. Add Waste 38. Drinking Water Flow 39. Drinking Water Return 40. Vacuum Cleaning 41. Compressed Air
Sprbdefera
. 42. Min Supplies 43. Branch and Head 44. Drain
CHAPTER 2
12. Traps 12.1 Boiler Return
o0
--G--------------________ ACIO
A-
12.2 Blast Thermo static
12.3 Float
12.4 Float and Ther mostatic
12.5 Thermostatic 13. Unit Heater
(Centrifugal Fan). Plan
14. Unit Heater (Pro peller), Plan
15. Unit Ventilator, Plan
16. Valves 16.1 Check
16.2 Diaphragm
16.3 Gate
16.4 Globe
Hooting 1. Air Eliminator 2, Anchor 3. Expansion Joint 4. Hanger or Support
PA
-X
- -----------E3 H
6. Heat Exchanger
6. Heat Transfer Sur face, Plan (Indieate Type Such aa convector)
7. Pump (Indicate Type Such as Vacuum)
8. Strainer
<
-6=6-
p-------- --- ---------- . . 11
ImJ---Q
9. Tank (Designate Type)
10. Thermometer 11. Thermostat
JL
16.5 Lock and Shield 16.6 Motor Operated 16.7 Reducing Pres
sure 16A Relief (Either
Pressure or Vacuum) 17. Vent Point
Ventilating 18. Access Door
19. Adjustable Blank Off
20- Adjustable Plaque
1960 Guide <t>
CE> -EE3-
------ <g>-----f |V|~ ~dj~T^T|
c*o
-Cskj-
TL,AO
TR 20X12 JP-20X2-7OOCfm
-------------- -j /P-20i*>#-7oo cftn
Abbreviations, Symbols, Conversion Factors
Ventilating
21. Automatic Dampers
y* "it"
22. Canvas Connections
23. Deflecting Damper
24. Direction of Flow
25. Duct (1st Figure. Side Shown: 2nd Side Not Shown)
26. Duct Section (Ex haust or Return)
27. Duct Section (Sup ply)
28. Exhaust Inlet Ceiling (Indicate Type)
29. Exhaust Inlet Wall (Indicate Type)
P4
L^V-Ce or r 2ox 12)
Eh---(5 20 X 12)
wy-wCR 20X >2 - 700 CfTft hiSJcc zox i2-700 cm
rv*TR-I2X& TOOCfm
Air Conditioning
39. Capillary Tube
40. Compressor
41. Compressor, En closed, Crankcase, Rotary, Belted
42. Compressor, Open Crankcase, Recip rocating, Belted
43. Compressor, Open Crankcase, Recip rocating, Direct Drive
44. Condenser, Air Cooled, Finned, Forced Air
45. Condenser, Air Cooled, Finned, Static
46. Condenser, Water Cooled, Concentric Tube in a Tube
47. Condenser, Water Cooled, Shell and Coil
48. Condenser, Water Cooled, Shell and Tube
49. Condensing Unit, Air Cooled
50. Condensing Unit, Water Cooled
30. Fan and Motor With Belt Guard
31. Inclined Drop in Re- t spect to Air Flow
f---- IT32. Inclined Rise in Re- r spect to Air Flow
33. Intake Louvers on Screen
1" 3
34. Louver Opening
35. Supply Outlet Ceil- ( ) *21 mg (Indicate Type)
I
>6. Supply Outlet Wall I (Indicate -Type)
1______ TR-12X6 1-------- -TOO Cf m
' 38. Volume Dampei
51. Cooling Tower
52. Dryer
53. Evaporative Con denser
54. Evaporator, Circu lar, Ceiling Type, Finned
55. Evaporator, Mani folded, Bare Tube, Gravity Air
56 Evaporator Mani folded, Finned, Forced Air
57. Evaporator Mani folded, Finned, Gravity Air
58. Evaporator, Plate Coils, Headered or Manifold
59. Filter, Line
60. Filter and Strainer, Line
61. Finned Type Cooling Unit, Natural Con vection
62. Forced Convection Cooling Unit
11
--]5TOp--
SW6r
-LA
/S -\
*1
BiiiD 1111118 K>
H