Document 4a80MEnB7BZ1YMaqzQq7LO7r1

10 23. Circulating Chilled or Hot Water Return 24. Make-Up Water 25. Humidification line 28. Drain 27. Brine Supply 28. Brine Return rtwthg 29. Soil, Waste, or Leader (Above Grade) . 30. Soil, Waste, or leader (Below Grade) 31. Vent 32. Cold Water 33. Hot Water 34. Hot Water Return 35. Fire line 38. Gas 37. Add Waste 38. Drinking Water Flow 39. Drinking Water Return 40. Vacuum Cleaning 41. Compressed Air Sprbdefera . 42. Min Supplies 43. Branch and Head 44. Drain CHAPTER 2 12. Traps 12.1 Boiler Return o0 --G--------------________ ACIO A- 12.2 Blast Thermo static 12.3 Float 12.4 Float and Ther mostatic 12.5 Thermostatic 13. Unit Heater (Centrifugal Fan). Plan 14. Unit Heater (Pro peller), Plan 15. Unit Ventilator, Plan 16. Valves 16.1 Check 16.2 Diaphragm 16.3 Gate 16.4 Globe Hooting 1. Air Eliminator 2, Anchor 3. Expansion Joint 4. Hanger or Support PA -X - -----------E3 H 6. Heat Exchanger 6. Heat Transfer Sur face, Plan (Indieate Type Such aa convector) 7. Pump (Indicate Type Such as Vacuum) 8. Strainer < -6=6- p-------- --- ---------- . . 11 ImJ---Q 9. Tank (Designate Type) 10. Thermometer 11. Thermostat JL 16.5 Lock and Shield 16.6 Motor Operated 16.7 Reducing Pres sure 16A Relief (Either Pressure or Vacuum) 17. Vent Point Ventilating 18. Access Door 19. Adjustable Blank Off 20- Adjustable Plaque 1960 Guide <t> CE> -EE3- ------ <g>-----f |V|~ ~dj~T^T| c*o -Cskj- TL,AO TR 20X12 JP-20X2-7OOCfm -------------- -j /P-20i*>#-7oo cftn Abbreviations, Symbols, Conversion Factors Ventilating 21. Automatic Dampers y* "it" 22. Canvas Connections 23. Deflecting Damper 24. Direction of Flow 25. Duct (1st Figure. Side Shown: 2nd Side Not Shown) 26. Duct Section (Ex haust or Return) 27. Duct Section (Sup ply) 28. Exhaust Inlet Ceiling (Indicate Type) 29. Exhaust Inlet Wall (Indicate Type) P4 L^V-Ce or r 2ox 12) Eh---(5 20 X 12) wy-wCR 20X >2 - 700 CfTft hiSJcc zox i2-700 cm rv*TR-I2X& TOOCfm Air Conditioning 39. Capillary Tube 40. Compressor 41. Compressor, En closed, Crankcase, Rotary, Belted 42. Compressor, Open Crankcase, Recip rocating, Belted 43. Compressor, Open Crankcase, Recip rocating, Direct Drive 44. Condenser, Air Cooled, Finned, Forced Air 45. Condenser, Air Cooled, Finned, Static 46. Condenser, Water Cooled, Concentric Tube in a Tube 47. Condenser, Water Cooled, Shell and Coil 48. Condenser, Water Cooled, Shell and Tube 49. Condensing Unit, Air Cooled 50. Condensing Unit, Water Cooled 30. Fan and Motor With Belt Guard 31. Inclined Drop in Re- t spect to Air Flow f---- IT32. Inclined Rise in Re- r spect to Air Flow 33. Intake Louvers on Screen 1" 3 34. Louver Opening 35. Supply Outlet Ceil- ( ) *21 mg (Indicate Type) I >6. Supply Outlet Wall I (Indicate -Type) 1______ TR-12X6 1-------- -TOO Cf m ' 38. Volume Dampei 51. Cooling Tower 52. Dryer 53. Evaporative Con denser 54. Evaporator, Circu lar, Ceiling Type, Finned 55. Evaporator, Mani folded, Bare Tube, Gravity Air 56 Evaporator Mani folded, Finned, Forced Air 57. Evaporator Mani folded, Finned, Gravity Air 58. Evaporator, Plate Coils, Headered or Manifold 59. Filter, Line 60. Filter and Strainer, Line 61. Finned Type Cooling Unit, Natural Con vection 62. Forced Convection Cooling Unit 11 --]5TOp-- SW6r -LA /S -\ *1 BiiiD 1111118 K> H