Document 4XeD6843qEzkqrXNLzb4Ej7e
RMC0000011
in^Acor.lPA^'TcoRUESPonDcnct
( <;* Vi
FROM:
*
C. T. Tash
-------jr r--~--------------------------------------------------------------------------------------------------- --* . (T^j S
v T O .
Homer Cole
C O P Y
OATC si SUBJECT
R. E. Herlean March 22, 1973
s February Industrial Hygene Survey
Dear Mr. Cole:
Attached are 3 letters which describe action being taken to correct the industrial hygene problems recog nized by you during your recent survey of the Plant. I have received the charcoal sampling tubes which we will be using to collect more solvent vapor samples at our coating and cleaning line as.well as at the Sheffield Plant.
We will commence with these as soon as the venti lation systems have been repaired and are operating more efficiently than in recent weeks. Solvent vapor samples will be forwarded to-'you for analysis shortly.
Sincerely,
.(`Ia.
C. T. Tash
CTT:lw
TX WHITE
002979
RMC0000012
INTRACOMPANY CORRESPONDENCE
FROM. _ TO
COPY
date a
SUBJECT
A. T. Henry
J. L. Kerins u/"'
L. A. Johnson, C. T. Tash
March 12, 1973
PRODUCTS CONTAINING ASBESTOS
Your letter of March 7, on the subject of using products con taining asbestos was passed on to me for reply. We have two conditions in the plant which will be discussed. One condition involves usage of material as production tools, the other is maintenance application where sawing is performed, and asbestos shorts are used.
The Cast House presently uses asbestos as one material for fur nace "doughballs". We are working toward discontinuing the use of doughballs in favor of ceramic cones. Other uses of asbestos material in production involves rope for trough sealing and sheet for temporary metal dam. This material is usually cut with a knife, causing no significant airborne particles.
We have two locations where asbestos materials are sawed to size for maintenance. In these areas we are taking positive action regarding the use of respirators, personal hygene, housekeeping, and dust collection. Vacuum equipment is on order.
Six individual tests have been made in the soaking pit area, and were found to be in compliance from the standpoint of exposure.
In summary, we have everything moving toward, (1) eliminating the product, or (2) providing adequate protection in the areas where asbestos is sawed.
If any further information is needed regarding our action on this subject please let me know.
ATH:lw
A. T. Henry sf?
TX WHITE
002980
RMC0000013
11 i i\ w u iti r mi i uunn l or u n u L iHi t
^-vs :r.-- ' ci3! .
|-i>
Ic_`
The letters from H.M. Cole of March 2, and March 6 on the above subject has been reviewed with Charlie Tash and Pete Akers*. The following action is being taken on each item:
ALLOYS PLANT
1. Paint Line airborne contaminates . New sampling tubes are being sent to John den Boer for sampling, and to be sent to Richmond for processing. This program will be underway in two weeks.
Engineering is checking out all ventilation systems and other controls for proper operation.
2. Box Shop Noise. Engineering controls are being instituted rather than administrative controls. The dust collection system is being insulated, a-flexible joint in the pipe, as well as dampers to close off when machines are not in operation.
The approach at the double end tennor is to insulate the noise at the source rather than the wall. This job is underway.
The chipper is the one problem for which we have no immediate answer. It is essential that an operator be near the machine on occasion when unplugging is necessary. Engineering*is making a study of ways to handle this noise source.
3. Process Furnaces. The carbon, monoxide leakage in the process furnace area was taken care of some weeks ago. Furnace seals were checked, and leaks repaired in this area.
II
TX WHITE
002981
RMC0000014
f'
2- -
SHEFFIELD CAN PLANT
1. Coater and Press Line Air Samples. Charlie Tash says the tests previously taken were inconclusive. He is initiating a new series of samples.
2. Noise Levels. The noise sources from the Yoder and Schmutz slitters, and the air compressor are on the schedule of Pontfetti for investigation.
A more detailed review of recommendatioi resampling and Engineering surveys are r
' ' when the
ATH:lw
TX WHITE
002982
RMC0000015
MfRA'COMPANY CORRESPONDENCE
is ' 1 -f 3)
s
a^r /7
FROM. J. S. Prestley - MRD
MRD#: 33-839-8R
-------TO. R. H. Mansur - GOB
C O P V
H. M. Cole - GOB; Dr . E. C. Irby - EXC>; R. E. Hughes, S. J. Sansonetti, G. E. Spangler - MRD
DATE a SUBJECT
March 5, 1973
PARTICLE COUNTS - ASBESTOS DUST
Listed below are the computed counts of total number of fibers per effective filter area for the samples submitted to Metallography. These are based on counts of 40 fields per sample (twice the specified minimum of 20 fields).
Sample No.
Calculated No. of Fibers Per Total Effective Filter Area
A1 106,442 A2 98,839 A3 0 A4 114,045 A5 22,809 A6 30,412
These values must be converted to particles per unit volume of air by your department since we did not receive the data for determining total air volume. The above figures represent relatively low counts and it is our understanding that this is due to short sampling times.
The counts above were determined using phase contrast microscopy and standard methods^*. Computation of fibers per total filter area was as follows:
Total No. of Fibers Per Filter Area *(Filter Area)X(Avg.
Count Per Field)
(Field Area) 2
Measured Effective Filter Diameter * 32#334 mm (Area = 821 um ) (Determined from opening in plastic.filter holder)
TX WHITE
RMC0000016
r
R. H. Mansur Page 2 March 5, 1973
2 Area of Microscope Field on Porton Reticle = .002756 ram
Average Count Per Field = (Total No. of Counts) (No. of Fields Counted)
The present fiber counts were made without regard to identification of the type of fibers. For example, it was reported that one of the samples counted was taken from an area where only fiberglass was involved. If samples in the future will be taken from areas known to contain fiberglass, we will have to adapt our present microscope for polarized light for fiber identification or acquire a microscope that is equipped for both phase contrast and polarized light. When a large amount of fiberglass is mixed with the asbestos fibers, the resulting counts could unnecessarily indicate violation of OSHA Asbestos Regulations. If future samples are to be taken in areas where particles of a nature other than asbestos are present, particularly fiberglass, provisions for identification of types of particles may be necessary.
l6
JSPtljo REFERENCES:
J. S. Prestley
Stephen G. Bayer, Ralph D. Zumewalde, Thomas A. Brown, "Equipment and Procedures for Mounting Millipore Filters and Counting Asbestos Fibers by Phase Contrast Microscopy," Bureau of Occupational Safety and Health, 1014 Broadway, Cincinnati, Ohio 45202, July, 1969
TX WHITE
RMC0000017
IN IKACOMPANY CORRESPONDENCE
R-?8 (Rev. 1-68)
In a telephone conversation with Charlie Tash on this date, the following recommendations regarding asbestos handling and usage should be followed:
(a) Provide and require all employees tearing out or cleaning up insulation containing asbestos with U. S. Bureau of Mines approved respirators.
(b) Dry sweeping of asbestos containing materials (cleaning up of insulation) or blowing off of asbestos from machining operations should be prohibited. All loose or spilled asbestos containing materials should be cleaned up with a vacuum system.
(c) Asbestos containing materials should be separated from any eating areas. Note: eating table was located in same area where shorts were being mixed and insulation being torn out at #7 soaking pit.
(d) Sawing of asbestos materials should be eliminated. If sawing or machining is necessary, it must be done on machinery that is properly ventilated. Note: sawing marinite board on an unventilated saw in the machine shop.
(e) Discontinue the use of dough balls in the cast house. Substitute with "Fiber Tap Hole Cones". Can be obtained from Consolidated Ceramic Products Company - Blanchester, Ohio.
(f) Empty "asbestos shorts" bags and other asbestos containing materials should be disposed of in an appropriate manner.
HMC:slc TX WHITE
H.M. Cole
RMC0000018