CHLORINATED METHANES GENERAL RESOURCE INFORMATION
I apartment: CMP
.ob Title: C-1540 General Resource Information
Scope: To provide the operator with the necessary information needed for the current IPT program
Liquid feed is pumped from D-1525. The feed consist of chlorine chloroform, and carbon tetrachloride. The purpose of C-1540 is to seperate chlorine and chloroform from the carbon tet.
The feed enters the column at tray 33 and flows downward thru the column. As the level increases in the bottom of the column the steam valve will activate and start driving the lighter components (chlorine and chloroform) toward the top of the column. The overhead vapor exits the column and enters the overhead exchanger EC-1540.
EC-1540 are fin fan coolers which are used to control the pressure of the column by condensing the gases that are coming out of the overhead of C-1540. As the pressure on the column increases, the pressure transmitter located on the overhead line sends a signal to the MOD V controller. The MOD V in turn sends a signal to the controller on the variable speed motors to increase thier speed. This will allow for more condensing of the gas entering EC-1540, thus lowering the column pressure.
The liquid that is condensed in EC-1540 is accumlated in D-1541. D-1541 is also called the reflux drum. Liquid from the reflux drum is pump back to the column as reflux via P-1541 A/B. What is not used as reflux is then level controlled as feed to C-1550.
Under normal operating conditions, C-1540 bottoms which contains PPM M3 & percent M4, are level controlled (AO 332) to T-809 via P-1540 A/B and E-1540A/B. In the event the bottom of C-1540 is out of spec it can be routed back to D-1525 via (DO 304/314). Also, recirulation will be maintain on P-1540 A/B C-1540 bottoms pumps at all times.
_
The column uses 235# steam on the reboilers (RE-1540 A&B) to control the level or the temp, of the column depending on the step the MOD is in . it will open or close to maintain the temp setpoint/level that is inputted into the controller.
d
DO 017697 CONFIDENTIAL
C-1540 GENERAL INFORMATION
PAGE 2
To help determine how much load the column can handle it is equipped with a differntial pressure transmitter which will indicate a differntial pressure across the column which will help determine when the column has reach maximum capacity and if flooding condition exist. The normal differential pressure is approx. 14 psig.
also
The column is equipped with several safety devices such as safety valve which are set at 150 psig and indep high level switches that are located on C-1540 bottoms and on D-1541. Transmitters are alarmed on MOD V with various set-points.
The normal concentrations of the bottoms product is from 10-90ppm M2, and lOOppm chloroform in the overheads normally less than 50 ppm.
DESIGN CRITERIA
Design temp Design press Design full vacuum Operating pres.(top/btm) Operating temp (in/out) Hydrostatic test #trays Tray matl. of Constr. Height Diameter (in)
DG 6/25/91
20/650 F 150 psig yes 20/35 168/253 1.5 roawp
115 410SS
175 ft 108 inches