Document 4QwO8Yav9nK5pzDVkgEJEMRa1

Inter Ollice Personnel and Organization Staff Mr. H. E. Budesky Division Safety Engineer Personnel Services Plastics, Paint and Vinyl Division 6 July 1983 cc V. J. Cfaolewka R. Steinhebel Subjects Bulk Sample Analysis for Asbestos , The sample from the Ho. 3 Reactor Recirculating Pump (Paint Plant) that you submitted 8 June 1983 was analysed for the presence of aBbeBtos type and percentage. Environmental Research Group, Inc. of Ann Arbor performed the analysis by polarized light microscopy (PLM). Results indicate positive identification for asbestos: Recommended Eight-Hour TimnWeighted Average Exposure Limits Amosite - 31S& ChryBotile - none detected Crocidolite - none detected 0.5 fiber/cc 2.0 fiber/cc 0.2 fiber/cc Therefore, this material must be regarded as containing asbestos, and all aspects of OSHA Asbestos Regulation 29 CFR 1910.1001 must be met. Please inform all appropriate parties of these findings and ensure that the Company asbestos policy is followed. A. i ygieniBt Ind ,,,, ology Department Employee Health Services 0 0 0 7 Cc?1 SCF-FORD-3343 PRODUCED BY FORD