Document 4Qa1w0eKJ3N43KENELZEoj0wa

Monsanto FROM lN,Mt * LOCATION' c. N. Keeney .- Galt Labs - 1730 DATE . SUBJECT : REFERENCE October 28, 1977 ^F (ADHESIVE^ DATA DEVELOPED THROUGH TESTTflETWO BATCHES OF GELVA S-55XH TO M. W. Farrar - R2E T. G. Iversen - B3NC P. W. May N. W. Touchette Various plasticizers were tested in two different batches of Gelva S-55XH at two different times (August and September) to determine the effect different batches of the same latex emulsion have on selected adhesive properties. Mixing and test procedures were identical for both series of formulations. Formulations studied in this project follow: Gelva S-55 XH Plasticizer 90 10 Viscosity stability testing will be the only test data reviewed in this report. The viscosity is tabulated so that the formulas tested at different times can be easily compared. Plasticizer Addition - 10% VISCOSITY STABILITY (CPS) 0.5 Hr. S-160 Aug. * 5800 S-160 Sept.* 6500 DBP Aug. 6650 DBP Sept. - 6800 ' Benzoflex 9-88 Aug. 6900 Benzoflex 9-88 Sept. 6700 Benzoflex 50 Aug. 7200 Benzoflex 50 Sept. 7200 XA 1012 Aug. 6700 XA 1012 Sept. 6900 XA 1013 Aug. 6600 XA 1013 Sept. 7300 1 Day 6550 5800 7300 6400 7100 6300 7200 7400 7800 7000 8100 7100 7 Days 6550 6100 6900 6800 6500 6700 7000 6600 7650 7500 8050 7200 14 Days - 6050 - - "6600 - 6400 - 6550 - 7150 - 7100 21 Days 6350 6100 - 6900 6650 6300 6550 6750 6600 7300 7100 7450 7150 28 Days 6600 6100 6900 6700 6200 6900 6850 6800 7200 7100 7400 7250 *Both lots of Gelva S-55XH had a per se viscosity of 3900 cps. One day : viscosity can be used as a reference point. s Oie day viscosity can be used as a reference point for comparison' since f most manufacturers consider that viscosity measurement as initial vis- [ cosity. The viscosity variation from batch to batch is illustrated as follows: ~ DSW 587173 STLCOPCB4092509 2. One Day Viscosity August September Change Santicizer 160 DBP Benzoflex 9-88 Benzoflex 50 XA 1012 XA 1013 6550 7300 7100 7200 7800 8100 5800 6400 6300 7400 7000 7100 - 750 - 900 - 800 + 200 - 800 -1000 With the exception of DBP all viscosities decreased in the emulsion tested in September vs results developed in a different batch of emulsion in August. It is not thought that the differences are caused by changes in mixing, testing procedures, ambient tempera tures, etc., because all of these variables were kept constant. It is thought the PVAc resin itself is different from batch to batch due to change in amount of protective colloid, surfactant used to make the PVAc emulsion. This phenomenon is reported by companies such as H. B. Fuller who keep a control on hand at all times in order to determine extent of viscosity change in different batches of resin. Formulas containing 15% plasticizer were compared as above and the same trend was seen in every single case where the viscosity for the resin batch tested in August was significantly higher than those developed in September. Again, it should be staffed that temperature differences from August to September do not account for the changes, since all samples are kept in the CTH room constantly. This study highlights a portion of the reason why viscosity numbers are so difficult to reproduce from batch to batch. What is hoped for in this type of testing is that the same trends are seen regard ing plasticizer influence on PVAc resin from batch to batch. Testing done in recent months indicate that trends have generally carried through different batches of PVAc resin tested. CNK/gls C. N. Keeney DSW 587174 STLCOPCB4092510