Document 4Q6Y4Me0ZdVVD0akr36pa46oe

S.V, ^43^, 244 ( AUTOMATED ) DATE PRINTED: CG 03 CODE mmmj DATE .> STANDARD HRS. KY-90S-D PKG LOT NUMBER f' TIME ' ____ M PROCESSES APPRO' < ) KY-908-D <G) FWP 03/26/82 <) <) <> <> <> () JOB NAME: 03KY908DMG CODE YC-3-B YC-3-B YC-3-B COMPONENT CONSUMPTION CODE LOT YC-3-B _____ YC-3-B ___ Yc-3-B ___ PQ LBS 93 93 ____ 93 'NON-BLEEDING EQUIP NAME 1KROLOR * YELLOW-LIGHT USE N- ACCT LBS CODE LBS EFORE USING SV, MAKE SURE t h a t N-28-D LINE TP ANY TT HI ANKFT) flFF RjJ>f'6&,<990 G) WATER IN V-203. SET AGITATOR ON IGH SPEED. IGH IN .DRUM f* POUR IN DUMP IN AND STIR 5 If IN ^ * RECORD: START,,__*)f|#_1^ W LOT . . f in 420 i 32-D | 163X50 IYC-3-BI <MP3\ /CfO i i i 420 3150 ADJUST TO 75* (1275 G) #NOTE: VOLUMES HIGHER. THAN 75" MAY CAUSE DUSTING IN EXHAUST HOOD. WITH AGITATOR ON LOW SPEED PUMP V-203 THRU TOMOG AT 2400-2600 PSI INTO V-205 V-203 MT, WASH COLOR THRU HOMOG WITH MIN HOT WATER AT 2400-26O0 PSI INTO V-205 . CORD: V-VOL ____6 ADJ TO 60* <2100 G) PECT HOMOG STRAINER ft CLEAN IF NECESSARY I & I RWMT"5M^)"WATS-INT0"'V"X25"START"'r'~""'r'' | J^fClTATOR \yar\ PUMP V-205 THRU HOMOG ATj^S00-520 PSI INTO .SV.. I | RECORD: TIME START TOTAL MINUTES__ L$. | | NOTE: IF. HOMOG PRESSURE FALLS BELOW 4800 PSI, | Jt 3-WAY VALVE WILL RECIRCULATE SLURRY TO V-205 \yf | WHEN V-205 MT, RUN IN 5* <240 G) WATER f PUMP *1 | THRU HOMOG AT 4S0O-52O0 PSI INTO SV SP STEP 01 - SET FORMULA SELECTOR TO POSITION 9 (V-243) OR POSITION 7 <V-244) RESS SV CAM RESET PB - SET 22 TC IN AUTO REMOTE <TEMP IS SET AT 190-194*F> RECORD'LEVELS 6 SET R/M COUNTER S=1 AS FOLLOWS: A. 11 LG PRESET #2 95 GAL | STRIKE FLOW CONTROLLERS AS FOLLOWS:: ' vS&Cf < N-27-D CONTROLLER) IN MANUAL 0,65 26 <N-27-D WATER) IN MANUAL LOCAL 5.2 RIO <NV27-D/WATER) RATIO 0.8 FC1 0 'N-32-D CONTROLLER) IN MANUAL 0.87 ^FC20 (N-32-D WATER) IN MANUAL LOCAL 4.8 '/8FC20 < N-32-D WATER) IN REMOTE 3FR10 < N--32--D/WATER) RATIO 1.1 GPM GPM GPM GPM 1 I | I 1 1 1i I JUN! 3 198| 1115-0 1 504 1 I I 27-D 1 213 1 1t 1 3.2-D I 147 ! 1' 1Ji I 1i 1i LOT DATE PRINTED: 3/24/82,' EQUIP I PACE 2 CG 03 KY-908-D MENTf i COMTYF' JOB NAME: 03KY908DMG I USE I LBS N- |ACCT CODE | LBS Y>HS i OPERATOR STEP PB 320 ,U 7 1 RECORD .LEVEL 2LG IF <35% FOLLOW SOLUTION SV T i MAKE-UP PROCEDURE. FOR N-27-D - SP jrfB I ADJUST SV TO 47" (2400 G) CP \X*9 I RECORD PH##.. ADJ TO 11.0-14 2 WITH N-7-D AT 5% (10 PARTS WATER TO 1 PART N-? D) . ^. ! SIPHON INTO SV. RECORD: pH OPERATOR STEP P.B ASSUME 50% V ,k 7-D " SP STEP 06/39. AFTER HEAT-UP RECORD: SV J&Tl SWITCH 3FC20, 8FC10, 6 8FC20 TO AUTO SP OPERATOR STEP PB SP STEP 10/43. WHEN 3FC20, 8FC10 & 8FC20 FLOWS ARE IN LIMITS, SWITCH 3FC10 TO AUTO G PB SP STEP 11/44. WHEN 3FC10 4. 3FC20 FLOWS ARE IN LIMITS, SWITCH 3FC20 TO REMOTE OPERATOR STEP PB DURING STRIKE RECORD:' SP STEP V-243/V-244 13/46 <30 MIN) RANGE TIME 9.3-10.O i.ie PH 14/47 (60 MIN) 9.3-10.0 15/48 <2 HRS) 9.3-10.0 16/49 (2 HRS, 25 MIN) Z3 9.3-10.0 jLLt 17/50 (FINAL 3 HRS) 7.5-8.5 Am_ NOTE: IF PH NOT IN RANGE, NOTIFY SUPV G NOTE IN LOG. IF FINAL PH >8.5, ADJ TO 7.5-8.5. G RECORD: PH SIFT IN .ASSUME 77% I 27-D | ____ 128-Al 50 385^+29 6 ADD 42* <320 G) WATER TO V-3S5 ADD & STIR FOR 2 MIN FOR S 57 ASSUME 50% I 260 I ... 7-D | ISO U-SY | DURING STRIKE CHECK LEVEL IN V-387. 387 |32 | IF LOW LEVEL LIGHT IS NOT'LIT, GO TO S-35 7 HJ;3 i IF LOW LEVEL LIGHT IS LIT, VERIFY BY CHECKING v34 i THAT LOW LEVEL PEG IN VAT IS ABOVE SURFACE IF VISUAL CHECK CONFIRMS LOW LEVEL, FOLLOW STEARATE MAKE-UP PROCEDURE. yP* ! RUN IN 25" (244 GAL). DO NOT MAKE UP THIS SOLUTION MORE THAN 30 MINUTES IN ADVANCE. DELAY BETWEEN END OF STEP 41 HEAT-UP AND START OF STEP 48 HOMOGENIZATION SHOULD B*E LESS THAN 30 MINUTES. 388 l>36 I TURN ON STEAM G AGITATOR 8 037 I ADJUST TO 32"-<317 GAL) AT 178-182F ! SET BADGER METER FOR 4663= 0S9 | PUMP IN FROM V-387-THlftrUNDERSURFACE DISTRIBUTORS AS FAST AS POSSIBLE .! \J?<$ SHUT OFF PUMP UKI STIR 30 MIN AT 178-182*F FOR S 48 uH2 DO NOT SHUT OFF AGITATOR 378 44 44 169-A 155-A 160-A 378 44 44 / DUP050046652 LOT DATE PRINTED: 3/26/82 C-S EQUIP MENT1 I PAGE 3 CG 03 KY-908-D | JOB NAME: 03KV908DMG I USE I LBS sv~~jj*rf' WHEN S28 COMPLETE HEAT SV TO 198-20 DEG F IN | & T 5 TO 10 MIN '| SP CLOSE WATER LINE & DISCHARGE VALVES AT STEARATE! PUMP i OPEN V-388 DISCHARGE VALVES. TO STEARATE PUMP | INLET ` I i OPEN, WATER VALVE AT STEARATE PUMP & RUN WATER I THRU HOMOG AT 29O0-3100 PSI, TO SEWER |. WHILE HOMOG WATER AT 2900-3100 PSI, OPEN HOMOG | DISCHARGE VALVE TO SV AND CLOSE VALVE TO I SEWER I IMMEDIATELY OPEN STEARATE PUMP DISCHARGE VALVE,| TURN ON PUMP 6 HOMOG V-388 TO SV AT 2900-31 OS| J .^r1 PSI* MAINTAIN SV AT 198-20*F. I WHILE HOMOG V-388.TO SV, SHUT OFF WATER VALVE I a *t PUMP ASAP '- I WHEN HOMOG COMPLETE, RINSE IN V-388 WITH HOT | WATER FROM HOT WATER MIXER WHEN S50' COMPLETE TURN OFF HOMOG 6 STEARATE I \ PUMP I STIR 5 MIN AT 198~200*F J SHUT OFF STEAM . WHEN S53 COMPLETE, OPERATOR.PB ./ I | SP STEP 23/53 RECORD PH_JLk__(3.3"3.7>' 1 1 IF NECESSARY, ADJ PH TO 3.3-3,7 (DOWNWARD ONLY)I & RECORD : PH_.^-: I NOTE; USE LIQUID ALUM, N-115-D. ADD TO SV VIA | BADGER METER. STIR 5 MIN AFTER EACH | ADDITION. ASSUME 50% 1 RUN IN N-7-D FROM S-^30 IN 10-12 MIN & STIR 5MINI RECORD: PHjglA <4.2-4.4) & IF NECESSARY, ADJ | TO PH 4.2-4.4 6 RECORD: pH_____. ASSUME 50% I (DILUTE 10 PARTS TO1,WITH WATER) ASSUME 78% I SIPHON N-7-D INTO SV I OPERATOR STEP PB I OPERATOR STEP PB ! SP STEP 60 - BATCH COMPLETE * 1 W NCODE 115-D 7-D 27-D ACCT LB | START | TIME - SP STEP 13.'o pw FINISH OPERATOR TIME SP STEP ___ '__________________ DUP050046653 DUP050046656