Document 4KYKN8ZQ67Jy3eoXJORGaXyR

March 23, 1992 Dow U.S.A. The Dow Chemical Company P 0, Box 150 Plaquemine, Louisiana 70765-0150 Daniel Cortez Eddie Guillory Petrin Petrin Building 4106 cc: Greg Miller Glycol II Building 5301 Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you, Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc OO A 114660 CONFIDENTIAL ASBESTOS MONITORING DATA RESULTS: GLYCOL II1992 **LOD ***LOQ EXPOSURE GUIDELINES 0-HR. TWA LIMIT - 0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE* PERSONNEL DESCRIPTION 3/9/92 13923 *456-26-3737 Insulator: Removing asbestos Insulation from 2* line WET METHOD USED 3/9/92 13920 *439-31-5689 Insulator: Removing asbestos insulation from 2" line WET METHOD USED DUfifMlN) 30 VQL(L) 71 LOD FIB/CC 0.51 "*LOQ FIB/CC <0.54 30 76 0.01 <0.51 * The proper protective clothing was worn during the job. North 7700 Respirator with HEPA titters were worn during the job. Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this information, we will establish 100 Flbers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which Is more representative of the actual fibers present) for asbestos monitoring. We will report berth Limit of Quantitation amt Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. 00 A 1 L OOMFTOFrvlTT Al LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE N2 13920 PLANT/DEPT. C? f \lCO f MONITORING FOR:. A?5 PV SAMPLE COLLECTION MEDIA: BADGE NO._____ TYPE. TEMP/HUMIDITY: (REQUIRED FOR BADGES). CHARCOAL TUBE SIZE_________________ "FILTER CASSETTE SIZE ASM"! a SILICA TUBE SIZE__________________ DRAGERTUBE TYPE_________________ OTHER __________________________________ SHIFT: 0T8HR. 12 HR. CT PERSONNEL SAMPLE AREA SAMPLE FULL SHIFT TWA STEl/TASK EMPLOYEE NAME. \P*> EMPLOYEE I.D.#_ JOB CLASSIFICATION. IH JOB CODE#______ CONTRACTOR COMPANY. blou,0/'J Co '-f- RESPIRATOR USED? S^ES NO (\jortkRESPIRATOR MODEL / CANISTER TYPE 0 MOUTH-BIT DUST "HALF-FACE FULL-FACE AIRLINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING DATE 3 OTHER CHEMICALS PRESENT:. PUMP SERIAL NO. <j 7^6 CALIBRATION DEVICE: O'BUBBLEMETER OTHER________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: 1. 2. art! 3.Z2Z2T BEGINNING FLOW RATE AVG.^ m-.ENDING:!.. 2,_^Q1 3.Z2S2" ENDING FLOW RATE AVG. 3TCC/MIN L/MIN g^CC/MIN L/MIN SAMPLE AVERAGE FLOW RATE 2S22- TIME STARTED to:no frM TIME STOPPED TOT. RUNNING TIMEtMlN! *30 SAMPLE VOLUME (AVG FLOW X RUN TIME) 1 (& Q/dtX>^h ^LgA**^ * ANALYTICAL REPORT REFERENCE # ANALYTICAL RESULTS: w * RESTRICTED FOR USE WITHIN DOW ONLY * Jii DO VP-124 Ao.6| FORM FILLED IN t: ' 1.1 DO A 114662 CONFTDFNTTAI. LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD G-LiSo / 'U'__ PLANT/DEPT. MONITORING FOR: ft bit's DATE, OTHER CHEMICALS PRESENT: sample N2 13923 SAMPLE COLLECTION MEDIA: BADGE NO.____ TYPE TEMP/HUMIDITY: (REQUIRED FOR BADGES), CHARCOAL TUBE SIZE_________________ O'TtLTER CASSETTE SIZE 3- T/Y7 M SILICA TUBE SIZE__________________ DRAGERTUBE lj umcn TYPE_________________ SHIFT: O'lfHR. Ol2HR. 0^PERSONNEL SAMPLE 0 AREA SAMPLE FULL SHIFT TWA 0 STEL/TASK EMPLOYEENAME EMPLOYEE ID# 4 f(j- - ~Z>1 b 1 JOB CLASSIFICATION. JsS.ute/or IH JOB CODE #______ CONTRACTOR COMPANY 'T-hfr'.t C'P RESPIRATOR USED? 0^ES NO t/orH- 110Q RESPIRATOR MODEL / CANISTER TYPE O MOUTH-BIT 0 DUSTT n0 HHAALI FF--FFAACrEF 0TULL-FACE 0 AIRLINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING PUMP SERIAL NO. QlRtf CALIBRATION DEVICE: S-SOfiBLEMETER OTHER________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: 1. 2. j.<T (jj 3. ^ BEGINNING FLOW RATE AVG. ? f?/ ENDING: 1. 2. 0 3 ENDING FLOW RATE AVG. 2 1 HR er'cc/Mm a l/min ^ If ft 0"cc/min L/MIN SAMPLE AVERAGE FLOW RATE ^(t' TIME STARTED TIME STOPPED (0. VS~ TOT. RUNNING TIME(MIN) _ /k^x- SAMPLE VOLUME (AVG FLOW X RUN TIME) ~1 (