TOWOLDMON0022062 WATER_PCB-00006531 MU-" S. Pat. Off. 1248 009668 7 TOWOLDMON0022063 WATER_PCB-00006532 .................................lu.s hern used successfully since 19-11 as a liquid phase heat transfer medium at atmospheric pressure ami temperatures up to WX) F. The compound. essentially tetrachlorobiphenvl, is a fire-resistant and non corrosive liquid, which does not crystallize at low temperatures. Handled properly, in well-designed forced circulation heat exchangers which avoid localized overheating damage, the fluid gi\es satisfactory continuous service for many years without replacement. Most significant. Aroelor 1218 is practically non-tlainiiiahle. hi one in stallation <>i record, a ruptured pipe spewed the hot fluid into gas flames: the fluid failed lo ignite! For general heat transfer, Aroelor 1248 has several other important qualities: it is highly mobile and can be readilv pumped at temperatures as low as .50 F. If cooling is necessary, the heat transfer fluid can he put through a water cooler and used as a coolant. Aroelor 1218 transfers heat (up to (j(K)'F. ) as a liquid. This liquid phase heat transfer makes it imneeessarv to use the expensive pressurized equipment requiied by a heat transfer medium that operates as a \apor. Aroelor 1218 operates safelv and efficiently with gas-final, oil-fired, or electrical heat sources. It is used stieeessfulb in the following t\pes of applications .... 0096688 I TOWOLDMON0022064 WATER_PCB-00006533 Chemical processing equipment, particularly for reacting flammable materials Cooking of alkyd resins, varnishes, waxes Plastics molding, extruding, calendering Rubber processing Heating asphalt Food processing, including potato chip and doughnut frying in vegetable oils Processing titanium, magnesium, other non-ferrous metals Fabrication of magnesium and aluminum honey-comb structures for aircraft Indirect heating in dyestuff manufacture Heating of corrugating rolls Indirect heating of distillation equipment Saponification of fats Calcining ovens Impregnation and lamination of fibrous materials 0096689 TOWOLDMON0022065 WATER_PCB-00006534 T\m,i. i Appearance Absolute density, g. ml. Absolute viscosity, centipoises Thermal Conductivity, Btu. 'hr.-sq. ft./F./ft. Spec. Volume, ml. g. Practically colorless mobile liquid. Temperature Centigrade Fahrenheit 1.44 30 86 1.41 60 140 1.37 100 212 1.27 200 392 1.17 300 5/2 112.0 30 86 17.5 60 140 4.2 100 212 0.99 200 392 0.47 300 572 0.0571 30 0.0564 60 0.0555 100 0.0534* 200 0.0512* 300 * Extrapolated Data 86 140 212 392 572 0.696 0.709 0.728 0.787 0.860 30 60 100 200 300 86 140 212 392 572 CONTINUED 0096690 TOWOLDMON0022066 WATER_PCB-00006535 nd.lc Spec. Heat. cal. g. TC. Vapor Pressure, mm. Hg. Distillation Range. ASTM D-20 Flash Pt., Cleveland Open Cup, ASTM D 92-45 Fire Pt.. Cleveland Open Cup. ASTM. 0 92-45 Pour Pt.. ASTM, 0-97 Average Coefficient of Expansion cc. cc. F, 0.283 0.297 0.326 0.355 0.00037 0.16 2.9 18.0 350.0 'Centigrade 50 100 200 300 37.8 100 150 200 300 345-385 'Fahrenheit 122 212 392 572 100 212 302 392 572 652-725 193-196 379-384 None 0.00037 0.00038 0.00041 0.00044 0.00047 0.00052 7 19.4 17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316 0 to 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600 PHYSICAL CHARACTERISTICS of AROCLOR 1248 A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat exchanger. These physical constants have a major bearing on the equipment design, its mainte nance, and its operation. The following figures and charts give basic physical data on Aroelor 1248. 0096691 TOWOLDMON0022067 WATER_PCB-00006536 TEMPERATURE DKNSITY OK AKOCLOR 124S ri'.p a\t'.. !!>.. C I1- Ft.; Ix.tloni n\iv tin. Jiil.i [00 0096692 TOWOLDMON0022068 WATER_PCB-00006537 VISCOSITY OF AKOCLOR 1248 TOWOLDMON0022069 WATER_PCB-00006538 0009 VISCOSITY OF AROCLOR 1248 (Saybolt Universal Seconds) Figure 3 T TEMPERATURE, DEGREES fAHRENHEIT 009669'. TOWOLDMON0022070 WATER_PCB-00006539 A HEAT CAPACITY and Its Relationship to Density Systematic errors exist in the various accepted pro cedures for making specific heat determinations Consequently values may vary depending upon the procedure used. In practical ojveration, it frequently appears that the values for Avoclor 1248 shown in Figure 4 arc somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative. When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Avoclor 1248 is much higher, relatively, than the density of other liquids used for heat transfer. Accord ingly. when comparison of heat capaoitv is made on a volume basis (which is most pertinent in equipment design and efficient operation) the heat capacity of Aroclor 1248 shows itself to better advantage than In direct comparison of specific heat v alues. Although specific heat values are iinjxntant. they represent only one of several important constants that enter into the equations for calculating over all heat transfer efficiency. Through the use of these conservative heat capacity values, it is possible that equipment engi neered from such data might he slightly "over designed." This may he one of the factors that accounts for the exceptionally good operating performance of a manlier ol highly successful commercial applications. 009*>b9^ TOWOLDMON0022071 WATER_PCB-00006540 SPECIFIC HEAT OF AROCLOR 1248 (Rtw. pvr lb. per degree F.) lii^iiHttaiHBmwiraMiiniii^^ ......... MttmMMMUBftfel** . -u.L - .... wmmmmmmmmmwmm&MmmmArnzi-- _________________ ____ _________________ .; --mmmmMmmmmmmmmmmmmmmm;. " iiiSIilS^ 1MM( ' ::rS. .-sin ;y ... : a__ _________ BBBiilllili&HilfiiiMiii^fe " ' .......' iiliiiiliiii^!: _ ilui.H'&'Ki-Hi iisi ___ ii. ' i'i i m&^m ^mMurnm iiiiitifefelfS 100 0-36 0.35 0 34 0.33 0.32 0.31 0 30 0 ?9 0 28 SPECIFIC HEAT Btu lb. F 00^66V6 TOWOLDMON0022072 WATER PCB-00006541 ; io \ __ Temperature C. CF. 0 32 10 50 38 100 66 150 93 200 121 250 149 300 177 350 204 400 232 450 260 500 288 550 316 600 TABLE II HEAT CONTENT of Aroclor 1248 Specific Heat Btu./lb./F. .269 .272 .280 .288 .295 .303 .311 .319 .327 .335 .343 .351 .359 Heat Content Btu./lb. 0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27 0096697 TOWOLDMON0022073 WATER_PCB-00006542 THERMAL CONDUCTIVITY and VISCOSITY The thermal conductivity values of Aroelor 1248 are shown in Figure 5. The curve shows this value over the operating temperature range, from 50'F. to 600 F., of Aroelor 1248. As freshly charged into a heat exchanger, Aroelor 1248 has an initial viscosity of 74 (S.U.S.) at 130F. which corresponds to a viscosity of approxi mately 5000 (S.U.S.) at 50F. -- which temperature is assumed for practical purposes to be about the limit at which Aroelor 1248 can be conveniently pumped with a centrifugal pump. The following table shows a comparison of the initial viscosity and the viscosity after a year's con tinuous service at 600F. in a LaMont forced circu lation heater: TABLE III Appearance Specific Gravity, 65' C. Viscosity, S. U. S. at 130 F. Original Color less Liquid 1.410 74 0 Alter one Year of service at 600"F. Dark Grown liquid 1.418 83 5 Although Aroelor 1248 tends to darken in use. this darkening is not harmful and does not indicate decomposition. In actual use at Monsanto, it has not been found necessary to replace the fluid after seven years of continuous use; additional fluid is onlv added as necessary to make up spills or leaks. In Figure 6, the horizontal line indicating vis cosity limit of pumpahility at 50 F. shows that the rate of viscosity increase based on a year's continuous service should permit Aroelor 1248 to serve approxi mately four years before increased viscosity mav inter fere with its pumpahility when cold. In practice. Aroclui 1248 has given satisfactory pumpahilitv for much longer periods. A simple S.l'.S. viscosity deter mination by the ASTM-D-SS method can be used jut periodic cheeks on the fluid. TOWOLDMON0022074 WATER_PCB-00006543 TEMPERATURE c THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted extension indicates extrapolated data) TOWOLDMON0022075 WATER_PCB-00006544 EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER VISCOSITY, SAYBOLf SECONDS, at 130F. YEARS OF USE AT 600 F 0096700 TOWOLDMON0022076 WATER_PCB-00006545 / i 14 STABILITY Aroclor 1248 is an extremely stable chemical com pound. Tests over lone periods of time have shown that 600 F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. below the initial temperature of its boiling range, and consequently re mains a liquid. Near its boiling point Aroclor 1248 tends to dchydrohalogenate to a very slight but measurable degree. If this occurs as a Tesult of accidental over heating. the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry. Experimental observations using ideally-suited heat exchangers operating at a temperature of 650 T with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated abuse GOO' F. at atmospheric pressure. When heated continuously at 650 "F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would he limited to about 6 months to one year. Results of operating at 600~F.. however, with out imposed nitrogen pressure indicate Aroclor 1248 can he heated continuously at this temperature for about 4 years before any viscosity increase could be expected to interfere with its pumpabihty at 50F. which is slightly below normal room temperatures. Provision should be made to prevent water contamination of the system. If the system becomes contaminated with water, any IIC1 liberated by local ized overheating may dissolve in the water film which will float on top of Aroclor 1248 in the expansion tank. The acidic solution thus formed can cause corrosion. It is recommended that moisture be eliminated from the expansion tank by installing a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off between periods of operation. ' Many years of practical operating experience have shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use. brass valves have been used satisfactorily. TOWOLDMON0022077 WATER_PCB-00006546 SAFETY of OPERATION Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature*2' is 1,299F. In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the freedom it offers from the hazard of fire propagation. An operators failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chamber. A weld rup tured and Aroclor 1248 poured into the red-hot fire chamber in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped. Insurance authorities allow the use of Aroclor 1248 heaters in mans' locations with a minimum of protection. No fire walls are icquired to isolate the heaters. Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of 266~F., the vapor pressure of the fluid vvoui : e only 1 mm. of Hg. SAFETY OF HANDLING Aroclor 1248 is an inert, unreactive liquid. If it is Med on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact. A skin burn resulting from accidental contact witli hot Aroclor 1248 should be treated in the normal manner for hot oil burns. Any liquid adhering to the burned area need not be removed immediately unless treatment of the burn demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used. The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged e\j>osure and should not be breathed, it is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissable in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, there should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors. i TOWOLDMON0022078 WATER_PCB-00006547 HEATER The most significant factor to remember when selecting or de signing a heat exchanger for Aroclor 1248 use is this: Aroclor 1248 transfers heat while in liquid form, at the maximum recommended temperature of 600"F. for continuous operation. which is approximately 50~F. below the boiling point. Conse quently, Aroclor 1248 does not form vapor to accelerate convection circulation. Ordinary fire-tube or water-tube heaters which depend solelv upon convection perform satisfactorily only at relatively low temperatures. When temperatures of 500-600"F. are required, a forced circu lation type heater is recommended. A satisfactory type of heater design would consist of a specified number of tubes in parallel, properly orificcd to provide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption throughout their entire length. A typical construction is shown in Figure 7. In its fabrication, the heater should be ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would be the expanded type, must be sealwelded to prevent leakage. All connections larger than %" should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for scaling joints and plugs. Drain valves should be installed at all low points on the heater and the vah s must conform with ASME requirements for "blow down valves. 0096703 TOWOLDMON0022079 WATER_PCB-00006548 Since a heater operating on Aroelor 1248 is completely filled with liquid, costly liquid-level controls and condensate return pij>es, fittings, traps, etc. are completely eliminated. Heaters can be provided with any desired kind of firing. Portable and small size stationary units are frequently elec trically heated; larger units may be gas- or oil-fired. In installa tions where an open flame presents a fire hazard, to meet insurance requirements the heater may be installed in a sepa rate building with piping carrying the hot Aroelor 1248 to the point of use. Properly constructed transmission pipes may ex tend for hundreds of feet. HEATER EFFICIENCY Forced circulation heaters with integral economizers will show an efficiency of from 75 to 80%. Heaters of the straight con nector type show efficiencies of 65 to 75%, depending upon the discharge temperatures. HEATER CAPACITIES Heaters using Aroelor 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,0(X) Btu. per hour per square foot of tube surface is regarded as satisfactory. For lower output rate, electrically-heated units are favored, einplov mg watt densities of 12 to 10 watts per square inch of element area. OO^b70** TOWOLDMON0022080 WATER_PCB-00006549 THE USERS The "users" or recipients of the heat at the point of processing can be any type of heating pan, platen, jacketed kettle, or coils nf steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Aroclor 1248 seldom exceeds 50 psig. In the user, however, it is important that all-welded construction be used. Threaded connections may allow leakage of the hot fluid. As in the heater, all connections %" and over should be flanged and all joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should be used to secure flanges. A typical system with several users is shown in Figure 8. MANHOLE FOR REMOVAL Of SlUDCL CLEANOUT DOOR 009670S TOWOLDMON0022081 WATER_PCB-00006550 THE PUMP For most systems, cast-steel centrifugal pumps with watercooled stuffing box and bearings are to be preferred. However, high temperature centrifugal pumps with mechanical seals are now available which give excellent performance. In some in stallations, immersion pumps have been used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands. To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a manner to avoid stresses on the hotly of tin* pump Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a positive differential control to switch off the burner in case of pump failure. When a new system is first put into operation, a slight leakage may be noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation. PIPING LAYOUT The most important factors in the piping layout for Aroclor 1248 systems are (a) proper sizing for the required flow rate and (b) minimizing pressure drop, because the sys tem will undergo temperature changes, adequate expansion joints and loops to relieve expansion and contraction stress un essential. Preferably, all pipe lines and connections should be of extra heavy or Schedule SO welded construction meeting A.S.M.E. requirements. However, Schedule 40 welded pipe construction is often employed. Flanged joints should be used as sparingly as possible to minimize potential leak points. All valves and controls should he cast steel coiotruction with stainless steel seats. Pipe lines should be well insulated and those exposed to temperatures below 70 F. diould be steam jacketed. All high points in the piping system should he pm\ ided with sent vahes; all low points should have drain connections. Piping should be well anchored at frequent intcixals particu larly near expansion loops, to prevent vibrations. Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 124S piping system. These may he varied to suit the installation. 0096706 TOWOLDMON0022082 WATER_PCB-00006551 THE EXPANSION TANK Ni<' tank should hr large enough to accom modate about 20'" of the total volume of the entire svstem. including the fluid content of tin* lieater. piping, and all heatnseis. Tank should lie sized to be 'i-full when svstem is cooled to 70 f-. and "-i-fuii when system is at maximum operating tem perature. Expansion tank should be fitted with a sight glass at the "full range and a float-ojierated low-level switch to shut off burner in case of accidental fluid loss in the svstom The expansion tank should he mounted on a platform high enough to support the liquid reservoir at least six feet higher than the highest point in the piping svstem. THE FEED and DRAIN PUMP To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump be installed at some convenient point to pump the Aroclor 1248 into or out of the system. CONTROLS Controls for heating systems using Aroclor 1248 should he installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory. Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in put to main tain the Aroclor 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off" or "high-low" con trollers, larger units may operate mure uniformly if equipped with modulating temperature controls. User Controls should ho installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of the heat-using equipment, hi a multiple-user svs tem. separate controls should be installed on each consuming unit, to assure the proper heat-deli\erv. Safety Controls. Tn addition to activating controls, the heater must also he fitted with the proper safety controls to meet the A.S.M.E. requirements. Safetv controls should include: 1. A high temperature limit control operating at the heater outlet to shut off the burner in the event of an excessive temperature rise. 2. A suitable low-limit temperature control to hold the burner at low fire until Die Aroclor 1248 in tin* svstem reaches a temperature level of isot.' The low limit temperature control is essential because llie viscosity of Aroclor 1248 is rather high at normal room tem perature. To avoid localized overheating upon start-up. it is not advisable to apply full heat from the burner until all the fluid in the system has attained a viscosity that allows good flow and unimpeded circulation. Cold start-ups require slow up-heats. Burners should be equipped with automatic ignition controls and flame failure controls. In wide-range fil ing opera tions, an over-fire, draft control will increase the economv of operation. Induced draft fans are another factor which should be considered as a means of avoiding the expense of high chimneys. Where they are needed throughout the system, good quality recording or indicating gauges should be installed. COOLING EQUIPMENT WTiere fast reduction of temperature is required, suitable air- or water-cooling installations may be used. If the cooler is to he a water-type unit, it is suggested that stainless steel tubing be used for the coils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature limit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the svstem. 00V6 70 7 TOWOLDMON0022083 WATER_PCB-00006552 FILTERING EQUIPMENT When heating systems operated on Aroclor 1248 are run continuously near the recommended maximum temperahire of operation (60CTF.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms. A small portable filter such as those manufactured by Uonan-Crane Corporation (Lebanon, Ind.) or Sparkler Manu facturing Company (Mundelein, 111.) is quite satisfactory. CONNECTIONS and GASKETS To minimize the possibility of Aroclor leakage, welded rather than threaded screw connections should be used. All connections %-inch and over should be of the flanged type, fastened with alloy bolts; spiral-wound gaskets of corrugated stainless steel and asbestos should be used with flanged con nections. For three-inch lines, 300 pound flanges fitted with eight three-quarter inch bolts should be employed. As a joint compound, a product like "Q" Seal* has been found useful. In all cases, steel connectors are recommended for all instruments and controls. TESTING THE SYSTEM When a new system has been installed it is essential to test for leaks. Testing with air should be avoided because of hazard of rupturing pipes or jackets. Testing with water is not recom mended because it is difficult to remove residual moisture from the system which should be kept dry. Halogen Testing for leaks is the recommended pro cedure. Introduce one pound of Freon F-12 or F-22 for each fifty cubic feet of volume of the heater and sys tem. Carefully introduce air not exceeding 10 psig of pressure. With up to 10 psig. of air pressure, the con centration of Freon will be sufficient to give sensitive test results. Attach a halide torch to an acetylene tank and light it. Using the Va inch hose as a probe, explore for leaks by passing the end of the hose along seams and joints. If a leak is present, the escaping Freon will Ik- drawn * A produet uf Quickie} Co., Inc.. 5<> W. 115th bt.. New York. V Y. into the acetylene flame turning it green. A large leak will produce a violet color. CLEANING THE SYSTEM After testing for leaks and making anv required repairs, the system must then be cleaned. A new system will contain dirt, mill scale and other foreign particles. Unless removed, these particles will bt; sus pended by the Aroclor. They may then lodge in valves, con trols and mechanical equipment and cause faulty operation. Purchasers of the heating equipment should request their suppliers to clean the equipment as thoroughly as possi ble, using brushes and wiping rags. Where state or local codes require hydrostatic testing and cleaning with water, the procedure described by card No. 1 may be used. However, it is not easy to remove residual mois ture from the system. Since moisture is not desired in the system, testing and cleaning with water should be avoided whenever it is possible to do so. Testing for leaks should be done as described above using Freon. After repairing any leaks, fill die system with Aroclor 1248, warn the fluid and circulate it thoroughly. The Aroclor will serve better than water for hydrostatic test ing and cleaning and will keep the system free from excess moisture. Since the Aroclor will pick up dirt and extraneous particles, it will be necessary to dean the fluid by filtration. To prevent filter arrangements, including screens from interfering with the required How of Aroclor through the system, the filters must not be installed permanently in the line of How. Tempo rary strainers in the suction side of the pump should be inspect ed frequently during initial start-iq) and removed when the system has proven clean. Tle Aroclor should be cleaned thorougldy using a by-pass filter, either a platten frame press fitted with dry filter paper and a thin bed of Attapulgus earth, or a convenient portable earthen cartridge type filter. Periodic use of this filtration equipment should assure that the Aroclor and die heating sys tem are dean at all times. In the event that the engineer chooses to carrv ovit testing and cleaning using water, it is very important that all moisture be purged from the system during the early hours of operation. Details art* given on Card No. 1. Following hydro static testing, periodic use of the filter equipment referred to above is desirable to keep the fluid and system clean. 0096708 TOWOLDMON0022084 WATER_PCB-00006553 GENERAL RECOMMENDATIONS for Operation and Maintenance The following recommendations are primarily guides for the manner of using Aroclor 1248 in an ojxrating system. They arc supplemental to tiro equipment manufacturer's own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up. shut-down, precautions in event of power failure, and periodic check-ups on the fluid and equip ment apply as generally accepted practice on all tvpes and sizes of systems. By following these recommendations, the troublefiee sen ice life of the heat transfer fluid will he increased. START UP When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow this start-up procedure: 1. Start the circulating pump and check the expansion tank to make certain the Aroclor 12-48 is at the proper cold-start level (Tank should lx* VWirli.) 2. Start burner at minimum flame setting and continue full circulation until Aroclor 1248 is heated to 180 F. when measured on the return side of the heater. 3. Turn heater up to full heat. PRECAUTIONS IN CASE OF POWER FAILURE by the heater controls. When power comes on, the circulating pump should first be run for a few minutes to eliminate ativ vapor pockets that might have been formed by the fluid's being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire may be resumed immediately, if the fluid temperature is above ISO F. PERIODIC CHECK-UPS The regular maintenance inspection schedule should include the? equipment manufacturers recommendations and also inspection of the heat transfer fluid. The following is a listing of check points. 1. Lubrication of moving parts. 2. Operating fidelity and ae cunu v <if n adimis of safety controls and temperature limit controls. 3. Inspection of heater tubes, burner, refractory linings. 4. Periodic cleaning of heater surfaces. 5. Inspection of water cooling at the circulating pump. 6. Regular repacking of stuffing buses according to the manu facturers recommendations. 7. Semi-annual or annual sampling and analysis of Aroclor 1248. SHUT-DOWN Under normal operating conditions not affected by fre I The following procedure will eliminate overheating of the fluid when shutting down: quent power failures or accidental oxerheating, when Aroclor 1248 is operated at 600'F. it should not be necessary to check oti the condition of the fluid more often than once or twice a year. 1. Shut off burner completely with circulating pump still oper ating. Continue to run the circulating pump at full head for The analysis for fluid condition is a simple determina at least lh hour to dissipate high residual heat in the com tion of viscosity. The information given in Figure 6 serves as a bustion chamber of the burner. guide to estimate the condition of the fluid, according to vis 2. Shut off circulating pump at the end of '4 hour and switch off all heater electrical controls. cosity values. Most users do their own testing; some have the viscosity determination tnade by an outside laboratory. PRECAUTIONS IN COLD WEATHER Customers can have their fluid tested bv Monsanto free of charge. A one-(|uart sample is required, and sample* should he I When heat exchanger is exposed to ambient tempera- enreftiilv packed to avoid breakage in shipment. Samples should tmes below oO F.. it is recommended that unit not be shut down. he shipped to; It is recommended that the burner be turned low and the fluid circulated cotrtinuouslv at about 200'F. The unit will then be "at ready for immediate high temperature operation. Monsanto Chemical Company Organic Chemicals Division Industrial Fluid Sales St. Louis 24. Missouri ABO\E IN FORMATION APPEARS ON POCKET CARDS INSIDE BACK COVER 0096 709 TOWOLDMON0022085 WATER_PCB-00006554 Designing or purchasing equipment fur a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the iiht and the heater. The actual heat which can he absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material bein': heated, both overall heat transfer coefficient and mean temperature difference aria in turn, affected by the flow rate of the Aroclor. This, inter-relation of flow rate, heat, and teui|>erature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Cn anctc1) may be used to minimize or eliminate trial and error. The following tables and orapb.s of physical properties and engi neering data are provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer lluid in the liquid phase. Tabic IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This lelation is also shown graphically in figure 10. The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in the texts of MeAdamsF) or Keni( ')- This is usually done by combining the individual film coefficient of the Aroclor witli other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temperature which are needed for calculating the Aroclor film coefficient. Table V 1 gives typical film coefficients for Aroclor Mowing through a 0.81 inch i.d. tube. These are listed as a function of temperature ami flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction tor tlie diameter in the Keynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various materials that might be processed by indirect heating may be found in the texts cited C*). ( ') ami elsewhere in the liteiatme. For sizing pipe lines ami pumping requirements. Figure 11 shoves pressure drop vs. flow rate and pipe size tor Aroclor 1248 at tempriatnre.s over 3(X) F. Above this tem|X*rature Aroclor 1248 flows freely like water. 0096710 TOWOLDMON0022086 WATER_PCB-00006555 I 33--qs35SsS?2225S55sssslll3S3ilIlssss55s;;ls3 s || 2???!si!i!!!!iB5i!!?S3i3|3K|ii|||iiii||igis2sssssgi t % 1 S55llll=lS251|1112|2||EllSlll|lllsi|lllllillli|Psg"S33SslSS i" " Is s:sls8ssslffissssllSsl^IiSS3ill3^^S5ISSSiSScSgSJ335S33;33g33S325 -| !ilIIIIS18iSS!sl!!ll!SiIlSISSlSS!IIS3Si8IISSl!l!!S!!1113!il! i sHijiiiiiiiMiiiiiiiiiiiiiiiiiiiiiiiiiSiiiiis ''2-~~TM"=SSSS::C:SSS3;SS=SSSS2S55SSss32SSsgggSss5~8sggs223gg 1 - i "Ssssgggggssassgg|HgBggsggS82sggssgsg2S5g58?82gSsssg8i2gg 1VI -,0^ TOWOLDMON0022087 WATER_PCB-00006556 FLOW RATES FOR AROCLOR 1248 TOWOLDMON0022088 WATER_PCB-00006557 TfnDeratjr 'F. 'C. 32 0 40 4 50 10 60 16 70 21 80 27 90 32 100 38 110 43 120 49 130 54 140 60 150 66 160 71 170 77 180 82 190 88 200 93 210 99 220 104 230 110 240 116 250 121 260 127 270 132 280 138 290 143 300 149 310 154 TABLE V THERMODYNAMIC PROPERTIES of AROCLOR 1248 PRA N DTI Absolute V'scositr __ Lbs. _ Hr. Ft. Thermal Condu:tn"ty Btu fT-hI~tT. CoM a 2060 960 485 278 160 114 77.5 58.0 43.5 33.8 26.6 22.0 18.2 15.2 12.6 10.6 9.45 8.10 7.26 6.48 5.76 5 03 4.75 4.40 4.07 3.83 0.0577 .0576 0.575 .0574 .0573 .0572 .0570 .0569 .0568 .0566 .0565 .0564 .0563 .0562 .0560 .0559 .0558 .0557 .0555 .0554 .0553 .0552 .0550 .0549 .0548 .0547 .0546 .0544 .0543 9844 4430 2353 1361 789 566 388 293 221 173 137 115 95 80 67 57 51.1 44.1 398 35.9 32.1 28.2 26.8 25.1 23.4 22.2 39.5 28.7 22.3 17.9 14.4 12.6 10.8 97 8.7 7.88 7.15 6.58 6.18 5 78 5.38 5.0$ 4.83 4.55 4.36 4.18 4.00 3.81 3.73 363 3.53 345 Temperature 'F. 'C. 320 160 330 166 340 171 350 177 360 182 370 188 350 193 390 199 400 204 410 210 420 216 430 221 440 227 450 232 460 238 470 243 480 249 490 254 500 260 510 266 520 271 530 277 540 282 550 288 560 293 570 299 580 304 590 310 600 316 Absolute Viscosity lbs. Mr. Ft. Thermal Conductirity Btu. ft. Hr *f. 3.53 .0542 3.34 .0541 3.14 .0540 2.95 .0539 2.78 .0537 2 66 .0536 2.54 .0535 2.42 .0534 2.32 .0532 2.20 .0531 2.10 .0530 2.03 .0529 1.93 .0527 1.83 .0526 1.76 .0525 1.71 .0524 1.64 .0523 1.57 .0521 1.51 .0520 1.45 .0519 1.38 .0518 1.33 .0516 1.28 .0515 1.22 .0514 1.18 .0513 1.13 .0512 1.09 .0510 1-04 .0509 1 01 .0508 Cp/ k 20.6 19.6 18-5 17.5 16.7 16.1 15.4 14.8 14.3 13.7 13.1 12.7 12.3 11.7 11.3 11.0 10.7 10.3 10.0 9.67 9.26 9.00 8.72 8.36 8.14 7.85 7 63 7.33 7.16 0 3.35 3.29 3.22 3.15 3.08 3.04 2.99 2.94 2.90 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.58 2.54 2.51 2.46 2.43 2 40 2.37 2.34 2.31 2.28 2.25 2.22 2 20 ooq b TOWOLDMON0022089 WATER_PCB-00006558 FLOW RATE, 6PM. F. 1.0 2.0 150 200 44.9 250 33.5 58.5 300 40.5 70.1 350 45.3 79.0 400 49.0 85 5 450 53.3 93 500 56.3 98 550 60.5 105 600 64.2 112 TABLE VI HEAT TRANSFER DATA for AROCLOR 1248 FILM COEFFICIENTS h^bri'23ki-Ji x 0023 L^J LtJroG-io-Brcp/no4 fMMcAdamsj Based M flaw tbreifii 1.11" I. D. tuba (1' 0. 0. 113 ga.) express* * Btu./sn. ft /br./T. 3.0 40 5.0 60 83.2 63.4 78.7 94.0 109 80.9 102 122 141 97 122 146 169 109 137 164 190 118 149 178 206 123 162 193 224 136 171 204 236 145 183 219 253 155 195 233 269 7.0 86.2 124 159 191 215 232 253 267 286 305 8.0 93.8 138 177 212 239 259 282 297 319 339 9.0 103 151 195 233 262 284 309 327 350 373 10.0 114 164 212 254 286 309 336 356 381 405 Calculations (or other pipe sizes can be made using the data toend in Tables IV and V. No dim coefficients were calculated for flow rales where the Reynolds number was less than 2100. 11.0 123 179 229 274 309 334 363 383 411 437 12.0 130 191 245 294 331 358 388 411 441 469 0096 71 A TOWOLDMON0022090 WATER_PCB-00006559 HEAD LOSS, FT, PER 100 FT. FRICTION LOSSES IN SYSTEM PIPING AROCLOR 1248. ABOVE 300 F. TOWOLDMON0022091 WATER_PCB-00006560 TYPICAL HEATERS USING AROCLOR 1248 A 200,000 Btu. (right) and a 300,000 Btu. healer, both gas-fired, have been in use at Monsanto tor over 14 years for organic chem icals reactions, the heaters have operated rear 600 F. with the same charge of Aroclor 1248 for periods ol 7 years 0096716 TOWOLDMON0022092 WATER_PCB-00006561 Valve n. On.bis hn-. diagonal take-ofi Aroclor outlet from cooler The Aroclor outlet from the cooler ties into the main line above the picture Coil return flange and bends Arcelor Heater: Each heater consists of fire brick-lined walls and bottom inside a steel shell with stee> baffles to force the hot combustion gases over th? Aroclor coil for tlree passes. The fop is a steel plate. Channel iron supports to raise the bottom of the heater above floor level Supports for cooler Right side water outlet Left side water inlet Cooler: Two-stage shell and tube construction with the Aroclor 1248 on the outside of the tubes. The two stage cooler is piped sc that one stage can be used on each Aroclor healer or both stages car be used on either Aroclor heater. 0096717 30 TOWOLDMON0022093 WATER_PCB-00006562 IIBHT A 40,000 Btu. per hour electrically heated portable heat exchanger used to heat vessels of about 50 gallons working capac ity. This unit was built for a variety of small scale chemical reactions. It was initially designed to vaporize approxi mately 200 lbs..-hr. of an organic com pound which has a heat of vaporization of 150 Btu. per pound; a 30% heat loss was allowed for. Expeiience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's lelt) would have beer more satisfactory. FIB BIGHT A 4,000,000 Btu..hr. forced circulation International LaMont heater. BIGHT Control panel tor a 3,000,000 Btu., hr. International LaMont heater that oper ates the 3,500 gallon, glass-lined kettle shown on the left. This kettle is the largest of its kind in the United States. FAB BIGHT Commercial heaters operating on Arocior 1248 are available in any capacity desired. This is a 1.200.000 Btu./hr. installation. 0096718 31 TOWOLDMON0022094 WATER_PCB-00006563 i 32 FAR LIFT A pilot plan) r?sin pressing vessel operated on indirect heat transferred by Aroclor 1248. vessel and tmater are mounted together in one unit. LEFT This 500.000 Btu. hr. forced circulation heater is electrically heated and designed for a liquid temperature ot 500 F. Ihe construction is similar to a double pipe heat exchanger with the electric heating elements in the inner pipe; the Aroclcr 1248 circulates through the annular space between inner and outer pipe. The liquid Arnclor 1248 is delivered from the heater at a temperature of 500 F. and heats the contents of a jacketed kettle with a batch capacity of 1.000 gallons. This design for a forced cir culation heater was de veloped by Cleaver Brooks Company. LITI-RAITHE CITKI) 1. Monsanto Chemical Co., St. Louis. Mo.. Application Data Bullet in 0-P-115 (1954). 2. Sullivan. M. V., Wolfe. |. K.. and Zisman. W. A., "Indus. Enj;. Cltcm.,"' -39. 1(507 M9I7). 3. Cranct I.. Heat Transfer Performance Curves'*. ChcmiKil Engineering. ]. 1ST-190. March, IU-m. L McAdams, W. II., "I lent- I ramintssion', McCraw-1 Mil Hook Co., Inc.. New York, ( 19-12). o. Kern, D. (}., "Pioccss Heat Transfer*', McC.r.iu-Mill Bock Co.. Inc.. New Y'.irfc? M950). 0096719 TOWOLDMON0022095 WATER_PCB-00006564 POCKET CARDS SUMMARIZING INFORMATION ON PAGE 22 HANOT FILE TAB lira forward and up aroclor LIQUID HEAT TRANSFER MEDIUM For temperatures up to 600 F. Long-lasting, trouble-free service Fire-resistant, non-corrosive Operates in un-pressured, minimum cost equipment Mtuisnutn xiipfilies troilor 12 tH. but not the fit-tit r.v<7i(/r".v Monsanto will he UtipjtY to rerontmentl source* of supply. 0096720 TOWOLDMON0022096 WATER_PCB-00006565 1 TESTING and CLEANING aroclor New or overhauled systems must be TESTED FOR LEARS and THOROUGHLY CLEANED OUT. This can be done in one operation as follows; Fill the empty system with cleaning solution (5 lbs. caustic soda and 5 lbs. of soda ash in each 1000 lbs. or 120 gal. of water). Thoroughly vent the system to insure complete filling. Close the vents and start the circulation pump. Start the burner at low fire, heat liquid to 180 F. Circulate solu tion at least 24 hours, During this time, periodically drain off from a low spot some of the solution and replace this volume with clear water. Do this until the fluid in the system is clear. This takes about 24 hours. When clear, raise the exit fluid temperature to 215-225F., then turn the burner and pump off. Next drain the entire system and open all vents. Residual heat will dry out the moisture. When inspection shows the system is thoroughly dry, dose all drains and vents. Now fill the system with Monsanto Aroclor 1248 until the expan sion tank gauge reads 1/4 full. Start the circulating pump and turn the burner on at low heat, Heat the fluid to 250F. (return temp.) over a two-hour period. During this time, vent the lines every 10-15 minutes to allow any residual water vapor and air to escape. Reinspect the entire system for leaks while fluid circulates. Again inspect the expansion tank to make sure it is 1/4 full. Finally, set the burner for full heat. Bring system up to normal operating temperature. Adjust all controls for full modulation. Examine all pipelines for expansion, adequate bracing and leaks. Proceed with normal operations. 2 391-04SS-4< (over) TOWOLDMON0022097 WATER PCB-00006566 Card No. 2 of 3 on operation of Aroclor 1248 heat transfer systems, GENERAL RECOMMENDATIONS FOR OPERATION and MAINTENANCE .. miWl248 HEAT TRANSFER SYSTEMS The following instructions apply to all Aroclor heating systems and are supplemental to manufacturers' recommendations for the equipment proper. 'follow these instructions any time a system has been shut down long enough for the Aroclor to cool beiow 180F.). ll-Start circulation rnnnn and check expansion tank (should be "l/4 full) ------ ------- --------------- ---------------------- pjstart burner on lowest heat and maintain full circulation until return fluid temperature reaches 1S0*F. 0S burner for full heat. Resume normal operation when fluid reaches proper temperature. Shut-down Procedure I (follow those instructions to prevent localized over-heating when system is being shut down}. Hshut burner off but maintain full circulation for at least 1/2 hour to dissipate high residual heat in combustion chamber. Qif air temperature is under 30F., keep fluid circulating constantly at 200F. i'ower failure automatically interrupts the burner operation. When power resumes, start the circulation pump to get rid of any vapor pockets that may ha\c formed in the heater tubes. If fluid is still hot (above 180F.), full heat may lie resumed when pipe knocking (if any; lias stopped. It returning fluid lias cooled below IfiO'F. during power failure and initial circulation, follow Start-up Procedure above. _ For mure details, consult Mornanto's booklet on ' "Aroclor 1248 Heat Transfer Data", or contact ^ ^ ^ q MONSANTO CHIMICAL COMPANY -- Organic Charaicolt Dlviiian Induitrlol Fluid* So I l, P. O. Box 478 -- St. livil, Missouri TOWOLDMON0022098 WATER_PCB-00006567 Cafcl No. of 3 on operation of Arocloc 1248 heat transfer systems TOWOLDMON0022099 WATER_PCB-00006568 JOJOO J y / Monsanto VI 0096723.01 TOWOLDMON0022100 WATER_PCB-00006569