Document 4Jr57qxZNLJ1vGR4Bk65Xxz2x
HAGER LABORATORIES, INC.
11234 E. Caley Avenue Englewood, Colorado 80111 (303) 790-2727 (800) 282-1835
REPORT ON SERVICE NUMBER 31254IH
February 25, 1988
--
To: Analysis:
Caroline Delong Southwestern Refinery Corpus Christi, Texas
The following samples were submitted for analysis: One membrane filter sample and two blanks for asbestos count.
Method:
ASBESTOS (count) The fiber concentration of each fil'trer sample was determined following NI0SH Method 7400. Wedges from each filter were examined at 400 power using phase contrast microscopy. All fibers longer than five (5) microns with a length-to-width ratio of 3:1 or more were counted as asbestos.
Results Discussion
The results are found on Tables 1, 2, 3, and 4.
The present 0SHA permissible exposure limit (PEL) for asbestos is 0.2 flbers/cc.
Analysis for Chemicals Harmful to Mankind
IB 001306
Page 2, SN 31254IH Southwestern Refinery February 25, 1988
Discussion (cont.)
Jie,
The sampling rates used were obtained from the 3M Compound Guide R35AG(611)R May 1981.
LT( ) indicates "less than" with the lower limit of quantification shown in parentheses."
All samples have been corrected for the blank unless otherwise noted.
Laboratory data are filed and available upon request.
Hager Laboratories Inc. has been AIHA accredited since 1977.
If you have any questions, please call customer service.
Submitted by MA/sn
'Maria Aleynikov Supervisor
IB 001307
SN 31254AH February 25, 988
TABLE 1
Sample Number
88-08 1 Blank 2 Blank
Counted Counted (fibers) (fields)
Total (fibers)
Air Volume Air Concentration
(liters)
(fibers/cc)
105.
1. 0.
79100. 100.
58200. LT(4380.) LT(H380.)
360. _
0.16 _
IB 001308
SN 31254IH February 25, 1988
TABLE 2
IB 001309
SN 31254IH February 25, 1988
TABLE 3
\
IB 001311
SN 31254IH February 25, 1988
TABLE 4
IB 001310