Document 4Jan6yykGwjX7Q990po8rnDe1

t INTERNAL CORRESPONDENCE IH FILE COPY UNION CARBIDE CORPORATION technical center P.O. BOX B361. SOUTH CHARLESTON. WV 25303 Kingrey ^""571014/102 A Cooy" P. 0. Gossage - 701/4 C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791 ' R. E. Sergent - 725 Dole September 14, 1987 Qn,j,J..,JDl;pt^TS _ HS&EA Area Sut,,ect Industrial Hygiene Asbestos Exposure Monitoring -'Non Abatement Attached are the results of the Asbestos exposure monitoring performed on electricians while pulling cable above ceilings. H. E. Reynolds and R. D. Hall were monitored in Building 2000 on August 25, 1987. E. E. Grinstead and W. J. Breckenbridge were monitored in Building 740 on August 27 and 28, 1987. Please refer to the monitoring results for the protective equipment worn by each. The exposure monitoring results indicate that the levels were well below the 0.1 fiber/cc Action Level, established by 0SHA for an 8-hour workday (TWA8). However, we still require wearing of half-face HEPA respirators, whenever working above ceilings and inside of pipe chases, until we have sufficient data to indicate that no problem exists. Please notify the monitored employees of these exposure results as soon as possible. Please have them sign and date this report and return to M. A. Patel at Building 701-330. If we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK BY: APPROVED BY: Vance E. Stover Attachment VES:MAP:rab 2678P Manhar A. Patel UCC 024419 ASBESTOS EXPOSURE MDNITtRINO Date 8-25-87 8-25-87 Sarrple Type/ Errployee Name Sampling Time Personal/ 2hrs 53nin H. E. Reynolds, Jr. Personal/ R. D. Hall 2hrs 49min Air Cone, Fiber/cc 0.0163 0.0281 T^8 Fiber/cc * * Personal Protective Equipment CCMCNTS Half-face HEPA-R12 Willson Respirator Collected while working above the ceiling in the North wing and core area of Building 2000 1st floor. Half-face HEPA-R12 Willson Respirator Collected while working above the ceiling in the North wing and core area of Building 2000 1st floor. 8-27-87 Personal/ E. E. Grinstead 2hrs 59min 0.0229 0.0085** Half-face Willson R12 fPA Respirator, disposable coveralls Collected while pulling coact cable above ceiling in Building 740 - 2hd and 3rd floor. 8-27-87 Personal/ 7hrs 20nin W. J. Breckenridge 0.0071 0.0065 Disposable Coveralls Collected while assisting Grinstead - did not go above ceiling. 8-28-87 Personal/ 7hrs 26min W. J. Breckenridge 0.0113 0.0105 Disposable Coveralls Collected while assisting Grinstead - did not go above ceiling. Personal/ E. E. Grinstead 7hrs 25min 0.0202 0.0187 Half-face Willson R12 HEPA Respirator, Disposable coveralls Collected while pulling cable above ceiling and in pipe chases in Building 740 - 2nd and 3rd floors. ASBESTOS -P--e--r-m---is--s--ib--le---E--x--p-o--s-u--r-e---L--e-v--e-l- Action Level 0.2 fiber/cc 0.1 fiber/cc OSHA *A TWAq was not calculated because this work was done after hours and it is not known if these enployees had any asbestos exposure, during the normal workday. **A TWAg was calculated because Grinstead had no asbestos exposure before the monitoring was performed and left the plant upon removal of the monitoring device. 267GP UCC 024420