Document 4JYn6YozbJonBeY7Yq5gKxmbp
'.
Monsanto
from <name * location)
DATE
SUBJECT
REFERENCE
TO
COMPANY CONFIDENTIAL
E. E. Stewart, W. G. Krummrich Plant
March 17, 1972
cc
POLYCHLORINATED BIPHENYLS (PCB) - SEWER ANALYSIS
Messrs. Clarrie Buckley Harry Campbell a Bill Caraway A1 Frerking Hap Horner Ron McEntira^T, Ed Ste war
. .;
Messrs. Bill Eng man Paul Heisler Art Leisy Bob McCutchan Scott Tucker - So.
' 2nd.
The addressees met 3/14/72 to review the present method of re
porting the amounts of chlorinated biphenyls present in the various
sewer streams that are analyzed. At present, a chromatographic
analysis is made of the sample. Calculations are made based on
peak heights, and chlorinated biphenyls .are reported as Aroclor 1221,
1242, 1248, 1254 and/or 1260. The respective amounts of each
reported Aroclor are totaled, and this latter amount is used to
calculate the amount of polychlorinated biphenyls (PCB's) present
in the sewer stream.
.
/
Each respective Aroclor is a mixture of different chlorinated bi
phenyls. The lower Aroclors contain more of the lower (mono)
chlorinated biphenyls, and the higher Aroclors contain more of the
higher (poly) chlorinated biphenyls. Some Aroclors contain the same
components. In tljiose cases when the component used for peak
height measurement is present in different Aroclors in the sample,
we are double counting. This is true when 1221 and 1242 or 1242 and
1254 are reported. Orthochlorobiphenyl is common to 1221 and 1242.
It was agreed by those present that the laboratory would discontinue, reporting specific amounts of 1221 and 1242 present unless a dis proportionate amount of 1221 is present. The analyst would make this judgement. This will eliminate double counting when both 1221 and 1242 are reported. At this time we will continue reporting 1242 or 1248 and 1254 or 1260 separately even though there is a slight overlapping of some components.
t
There was some question when we began producing 1105 and 1109 whether we should report monochlorinated biphenyls as PCB's in the sewer streams. The guide given by W. B. Papageorge was "if the amount (A-1221 or A-1109) begins to exceed the amounts of other PCB's present, we should report as PCB".
J. SW 295979
STLCOPCB4065923
Clarrie Buckley
Hap Horner
Harry Campbell
Ron McEntire
Bill Caraway
Ed Stewart
A1 Frerking
POLYCHLORINATED BIPHENYLS
(PCB) - SEWER ANALYSIS
-- Page 2 WGK 3/17/72
Therefore, using the above information as a guideline, I suggest:
1. When peak heights would indicate the 1221 amount to be less than 1242 or 1248 and 1254 or 1260, do not include 1221. If the peak height would indicate the presence of some 1221, so state on your tabulation sheet.
2. When peak heights would indicate the 1221 amount to be greater than 1242 or 1248 and 1254 or 1260, include 1221 as a separate Aroclor being present.
Please note the attached table. Based on previous analyses, I would recommend we count or not count as I have indicated.
Edward E. Stewart
/emz att.
DSVsl 29598
X
STLCOPCB4065924
REPORT PRESENCE OF 1221
X
.
-
X X X X X X
X
AROCLORS
. ft
1221
1242 or 1248
1254 or 1260
292 ppb __________15<? PPb
440
641
15 22
80 73
103 31
189 * ' 45
311 607
17
288 727
21
25 61
95 122
48 64
534
823
2697
1923
121 31
1920
209 36
1320
3985
7148
` 728
268
21900
22300 5061
406
47
21 12
46 78
114
190
9 51 22 392
29 59 18 20 5
1 5 ppb 224
7 50 70
7 127 245
8 22
52 15 174
184 10
* 3743 140 50 39 70 2 17 180 60 21 18 7 95
-
DO NOT REPORT PRESENCE OF 1221
X X X X X X X X X X X X
X X X
X X X X X X X
X
STLCOPCB4065925