Document 4JYn6YozbJonBeY7Yq5gKxmbp

'. Monsanto from <name * location) DATE SUBJECT REFERENCE TO COMPANY CONFIDENTIAL E. E. Stewart, W. G. Krummrich Plant March 17, 1972 cc POLYCHLORINATED BIPHENYLS (PCB) - SEWER ANALYSIS Messrs. Clarrie Buckley Harry Campbell a Bill Caraway A1 Frerking Hap Horner Ron McEntira^T, Ed Ste war . .; Messrs. Bill Eng man Paul Heisler Art Leisy Bob McCutchan Scott Tucker - So. ' 2nd. The addressees met 3/14/72 to review the present method of re porting the amounts of chlorinated biphenyls present in the various sewer streams that are analyzed. At present, a chromatographic analysis is made of the sample. Calculations are made based on peak heights, and chlorinated biphenyls .are reported as Aroclor 1221, 1242, 1248, 1254 and/or 1260. The respective amounts of each reported Aroclor are totaled, and this latter amount is used to calculate the amount of polychlorinated biphenyls (PCB's) present in the sewer stream. . / Each respective Aroclor is a mixture of different chlorinated bi phenyls. The lower Aroclors contain more of the lower (mono) chlorinated biphenyls, and the higher Aroclors contain more of the higher (poly) chlorinated biphenyls. Some Aroclors contain the same components. In tljiose cases when the component used for peak height measurement is present in different Aroclors in the sample, we are double counting. This is true when 1221 and 1242 or 1242 and 1254 are reported. Orthochlorobiphenyl is common to 1221 and 1242. It was agreed by those present that the laboratory would discontinue, reporting specific amounts of 1221 and 1242 present unless a dis proportionate amount of 1221 is present. The analyst would make this judgement. This will eliminate double counting when both 1221 and 1242 are reported. At this time we will continue reporting 1242 or 1248 and 1254 or 1260 separately even though there is a slight overlapping of some components. t There was some question when we began producing 1105 and 1109 whether we should report monochlorinated biphenyls as PCB's in the sewer streams. The guide given by W. B. Papageorge was "if the amount (A-1221 or A-1109) begins to exceed the amounts of other PCB's present, we should report as PCB". J. SW 295979 STLCOPCB4065923 Clarrie Buckley Hap Horner Harry Campbell Ron McEntire Bill Caraway Ed Stewart A1 Frerking POLYCHLORINATED BIPHENYLS (PCB) - SEWER ANALYSIS -- Page 2 WGK 3/17/72 Therefore, using the above information as a guideline, I suggest: 1. When peak heights would indicate the 1221 amount to be less than 1242 or 1248 and 1254 or 1260, do not include 1221. If the peak height would indicate the presence of some 1221, so state on your tabulation sheet. 2. When peak heights would indicate the 1221 amount to be greater than 1242 or 1248 and 1254 or 1260, include 1221 as a separate Aroclor being present. Please note the attached table. Based on previous analyses, I would recommend we count or not count as I have indicated. Edward E. Stewart /emz att. DSVsl 29598 X STLCOPCB4065924 REPORT PRESENCE OF 1221 X . - X X X X X X X AROCLORS . ft 1221 1242 or 1248 1254 or 1260 292 ppb __________15<? PPb 440 641 15 22 80 73 103 31 189 * ' 45 311 607 17 288 727 21 25 61 95 122 48 64 534 823 2697 1923 121 31 1920 209 36 1320 3985 7148 ` 728 268 21900 22300 5061 406 47 21 12 46 78 114 190 9 51 22 392 29 59 18 20 5 1 5 ppb 224 7 50 70 7 127 245 8 22 52 15 174 184 10 * 3743 140 50 39 70 2 17 180 60 21 18 7 95 - DO NOT REPORT PRESENCE OF 1221 X X X X X X X X X X X X X X X X X X X X X X X STLCOPCB4065925