Document 4JGVnQg5pyKVqvqejr79d8Kea
Heat transfer fluids are intended only for indirect heating purposes. Under no circumstances should this product contact or in any way contaminate food, animal feed, food products, food packaging materials, food chemicals, pharmaceuticals or any items which may directly or indirectly be ultimately ingested by humans. Any contact may contaminate these items to the extent that their destiuction may be requited. Precautions against ignitions and fires should be taken with this product.
NOTICE: Nothing contained herein is to be con strued as a recommendation to use or sell any product in conflict with any patent. MONSANTO MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, AS TO MER CHANTABILITY, FITNESS FOR PARTICULAR PUR POSE, OR OTHERWISE WITH RESPECT TO ANY PRODUCT REFERRED TO, whether used alone or in combination with any other material. Monsanto makes no guarantee of satisfactoiy results from reliance upon information, statements or recom mendations contained herein and disclaims all liability for any resulting loss or damage.
In certain countries of Western Europe and the Far East, Monsanto sells Therminofc&Heat Transfer Fluids under the brand name "Santothcrm* Heat Transfer Fluids'* Corresponding Therminot and Santothcnn heat transfer fluids am Identical in composition.
Table of Contents
}
Physical and Chemioai PmportiOfl......................... t
Typical Properties.................................. 1 )
Introduction............................................................ 2 I
Applications.............................................................. 2 I
Fluid Parameters and Selection Criteria............... 2 i
Stability................................................................. 2
Heat Transfer Coefficient.....................................2
Safety-ar^HanriliagTf; .iwwi'ffh i n m
Design Recommendations...............
2
Operation Procedures......................................... ?2%
Start-Up.................................................................t3 3-
Shut-Down............................................................3
General Design and Maintenance......................... 3
TablesapdGraphs,....................
4-9 ..
T^enSl^T^ W**/"'1***-' **** Tks*fAAAzkkA4 -
I Viscosity............................................................ jrS
^ Variation of Properties ^HyTnraperatupo nt tig.
Thermal Conductivity .. r.TT.........,
. .. 6
Specific Heat..................................
6
Density/Volume Relationship
.. 7
Pressure Drop..................................................... S
Heat Transfer Coefficients.
.......................9
*Ragistrl tr*dmrit < Mmm
06l^62
TOWOLDMON0039371 WATER_PCB-00023840
Chemical and Physical : Characteristics
' Therminol* 75 is a synthetic aromatic
heat transfer fluid.
.
| It has a liquid operating temperature
j range of 160"-750ftF.(70*-3999C).
' Because of its high boiling point | 1725F), Therminol 75 heat transfer
fluid generates veiy little vapor
'
. pressure above ambient pressure ! and can be used In low pressure
j aystemsyUnder ambient conditions,
| Therminol 75 is a soft, solid material
, having a melting range of about
, 104*-!Se*F (40*-70*C).
IS*
*/*
.
Typical
3B2
***<r. <K
Properties*^
Composition Appearance
.
Melting Range, *F
Flash Point, (COC) Fire Point, (COC1 AIT ID-2155) Density @ 122F Kinematic Viscosity
@ 122F Coefficient of Thermal
Expansion1 . Heat Of Vaporization
(Calculated) Average Molecular
Weight Boiling Range:
@ 50 mm Hg
Terphenyl/Quaterphenyl Soft, Solid Melting to Yellow
Liquid
104*-158F (40*-70*C) Reluctant to Ciystallize
390F (204C) 440*F (232*0 1000* F 1538*0 9.08 lbs./gallon
97.9 cSt
0.000489/"F (0.000880/*C)
103 BTU/lb. (57 cal/gm)
255 10%
255*C
90% 340 C
/V,-V,> 'Calculated by equation C - \T **T, yj wilh T, 10*P and T* 7S0*F.
n.eM data are based upon samples tested In (ho taborstoiy and an not guaranteed for *11 samples. Write us for complete sales specifications for Therminol 74 hoal transfer fluid.
tDoesnot constitute an express warranty. See NOTICE at front ofthis bulletin.
TOWOLDMON0039372 WATER PCB-00023841
Introduction
.
Therminol 7&noat transfer fluid is a now high temperature liquid phase heat transfer fluid having excellent thermal stability. It was developed for use at temperatures of 700 750F (371-399C) in typical liquid phase heat transfer systems which : operate at low pressure (about one and one-half atmospheres or less static pressurization) to maintain the liquid phase at high temperatures. Therminot 75 is non-corrosive to typical heat transfer system mate rials of construction, has low odor and low mammalian, toxicity.
Therminot 75 is not classified as a fire-resistant heat transfer fluid. Con sequently, the use of protective devices may be required to mini mize lire risk. The insurer of your property should be consulted rela tive to this matter.
Applications
The design and properties of Thermino) 75 make it ideally suited for high temperature heat recovery applications in process and reflnety operations, such as providing indi rect heat to chemical process, heat recovery from stack gases, as a coolant to remove heat from exo- ; thermic reactors and for indirect heating of distillation processes.
Use of Therminol 75 in 700*-750"F (37t-399CI heat transfer systems can result in savings of capital investment, fluid makeup, utility and maintenance costs as compared with higher pressure liquid-vapor . systems.
,.
Fluid Parameters and Selection Criteria
In the selection of a heat transfer fluid for high temperature use, it is impoilant that one consider the fluid properties and characteristics. Some of these are listed below:
JStability^herroinol 75 is an excep tionally!heat stable fluid; however, care must be taken to avoid over heating the fluid which could lead to decomposition products.
The stability of a fluid is one of the most Important considerations in the selection of a heat transfer fluid. The fluid should be capable of with standing severe thermal stress for long durations of time and provide desirable overall long service life. As such, the chemical makeup or composition of the fluid must resist thermal degradation.
Overheating and exposure of the
heat transfer fluid to thermal con
ditions above the recommended '
operating range of the fluid can
result in increased decomposition of'
the fluid to low boiling and high
boiling products. The low boiling
products can result in pump cavita- ;
tion and localized boiling in the :
heater. These low boilers should be
vented through a pressure relief
device on the expansion tank to a
non-hazardous area away from
personnel and sources of ignition. .
The high boiling products are gen
erally soluble in the fluid. High
boiling products may possibly
|
separate as solids (coke, tar, etc.)
and could be detrimental to the
operation of the system. Thus when '
detected they should be removed.
Contamination may accelerate the thermal breakdown of a fluid, thus it is recommended that new and used heat transfer systems be cleaned thoroughly before filling with Therminol 75 heat transfer fluid. It is also important that oxida tion of the fluid be kept to a mini mum during high temperature operation by use of a positive nitro gen pressure on the expansion tank to which a pressure relief device should always be provided.
Heat Transfer CocfTicientjrhermJnol 75 heat transfer fluitThas equiva lent or higher heat transfer coeffi cients than other natural or syn thetic liquids in the same boiling range. As with all thermal liquid heat transfer systems, the flow should be fully turbulent in the heater and users to effect efficient heat transfer and avoid hot spot boiling which can lead to fluid de composition and surface fouling or heat transfer surface bum-out.
1 Design Recommendations
Besides the design and operation guidance given in Monsanto bulletin IC/FP-204, Therminol 75 heat transfer fluid with its 40-70C melting range will require:
heat tracing of system components for thawing the heal transfer media to the liquid state.
continuous heat tracing of instru mentation and control lines, system vents and other components which during system operation are cold and would not be operable with solid heat transfer media.
a thermal heatable storage that can accommodate the heat transfer sys tem volume in case of emergency shut-down of utilities or drum stor age which could be thawed out at a later time.
All system low spots to have drains to facilitate fluid discharge and system cleaning.
^Operation Procedures
Start-Upy^n addition to suggested start-up procedures in bulletin IC/FP-204, systems using Therminol 75 heat transfer fluid/ must be pre heated as must the Therminol 75 . to a temperature above thetsaS-l* !?& $^0C) melting point and not be allowed to fall below this temperalure. While Therminol 75 is reluctant
TOWOLDMON0039373 WATER PCB-00023842
jto ciystallize, the best operating > practice is to have the system start
up temperature above 160F (~70C). Two methods or combinations have been employed for preheating the system. The first is to have all com ponents heat traced and the system preheated by the tracing. A second method is to introduce low__ f pressure steam into the expansion tank and allow internal steam heat* Ingwith condensate and steam { exiting the system through the sys-
i tem drains and vents. This is | especially useful where heat tracing t of large heaters and user compo- . I nents is impractical. All system i component temperatures should be I monitored to insure complete heat* 1 Ing. The Therminol 75 is charged at above 1G0F l~70CI to the system ' from thermally heated bulk storage . or heated drums. The continuous ; heat tracing of instrumentation lines, ! system vents and pump shaft seals 1 must be in operation before the sys
tem pumps and heaters are started. The expansion tank vents should be open to allow moisture to exit the system horn the hot fluid moving through the expansion tank. After the free moisture has left the sys tem, the expansion tank should be . inert gas blanketed and normal operation commenced.
CShul-Down) For shut-downs for systems which are not totally heat traced and the minimum system temperature is less than 160 F (--70C), Thcmilnol 75 heat transfer fluid must be removed from the system and placed in heatable Storage. All low point drains must be opened to remove Therminol 75.
General Design and
Maintenance
A design, operating and mainte nance guide for liquid phase, low pressure heat transfer systems uti lizing Therminol heat transfer fluids is separately available. This brochure (IC/FP-204) discusses many general aspects of heat transfer systems. It may be obtained by contacting your sales representative or Monsanto Industrial Chemicals, St. Louis, Missouri (314-694-1000).
Safe Handling and
Disposal
-
Both animal toxicity studies and
manufacturing experience indicate
that no special precautions are
required in the handling of
Therminol 75 heat transfer fluid at
ambient temperaturesTriowever, it
is suggested that good*industrial
practice relating to the avoidance of
repeated and prolonged skin contact
to any industrial chemical, heat
j
transfer fluids, or petroleum product '
be followed. Vapors on the other '
| hand while not dangerously toxic
! normally can give rise to discomfort;
' systems should be made as leak
< tight as possible. Repairs to leaks of t
; hot fluid should be carried out .
' under wel) ventilated conditions.__ ; ^Vhile it is believed that Therminol
75 heat transfer fluid poses no seri ous problems with respect to the environment, as a concerned sup plier to industry, Monsanto urges
-'J'K'O-V
JUjko-u^ 5
1
the user to maintain a tight system," to correct leakage promptly, and to | exercise care in the handling and ! disposal of this and all other such , products. A tight maintenance pro ! gram not only protects the environ| ment, but keeps employes comfortj able, the working area clean and the system running smoothly. The most ; environmentally acceptable means i of disposal of used fluids is incin eration.
Material Safety Data Sheets and Sales Specifications may be obtained from Product Acceptability, Specialty Chemicals Division, Monsanto ; Industrial Chemicals Co.
Monsanto Analytical Service
Should a system experience heat transfer fluid related problems, Monsanto will evaluate the used Therminol or other fluids against UNJJSE experience guidelines. In ] many instances, these analyses have resulted in modest system changes to eliminate problems and in identi- ; fleation of external contamination.
'Uaji
(J) CtAcJxJ'n&JU
'to > 0-v\
0615965
S' I
TOWOLDMON0039374 WATER_PCB-00023843
I Variation of Properties Willi Temperature**
Temperature
*F. c.
Density Ib/gfll Ib/fi* Kg/m*
Specific Heat
BTU i
n*F kg*K
Thermal Conductivity
BTU hr ft*F
W m'K
Viscosity
Absolute Kinematic
ib/hr-ft
cSt
Vapor Pressure
Torr psia (mm Hg)
120 ,.140 , 160 :180
200 i 220 i 240 ! 260 280 1 300 ' 320
' 340 360
: 360 : 400 i 420
; 440 '460 480 | 600 1 620
: 640 ' 560
560 600 i 620 : 640 : 660 j 660
! 700 1 720 i 740
1 750' ' 760
49 60 71 82 93 104 116 127 136 149 160 171 182 193 204 216 227 238 249 260 271 282 293 304 316 327 338 349 360 371 382 393 399* 404
9.09 9.02 8.95 6.89 8.62 8.75 8.69 8.61 8.55 8.48 6.41 8.35 8.28 8.21 8.14 8.08 8.01 7.94 7.87 7.80 7.74 7.67 7.59 7.53 7.46 7.39 7.33 7.26 7.19 7.12 7.05 6.98 6.94 6.91
67.99 67.49 66.99 66.49 65.99 65.49 64.99 64.43 63.93 63.43 62.93 62.43 61.93 61.43 60.93 60.43 59.93 59.37 58.87 58.37 57.87 67.37 56.81 56.31 55.81 55.31 54.81 54.31 53.75 53.25 52.75 52.19 51.94 51.69
1089 1081 1073 1065 1057 1049 1041 1032 1024 1016 1008 1000 992 984 976 968 960 951 943 935 927 919 910 902 894 886 878 870 661 853 845 836 832 828
0.390 0.397 0.404 0.411 0.419 0.426 0.433 0.440 0.447 0.454 0.461 0.468 0.475 0.482 0.489 0.496 0.503 0.510 0.517 0.523 0.530 0.537 0.544 0.551 0.558 0.565 0.572 0.579 0.586 0.593 0.600 0.607 0.610 0.614
1633 1662 1692 1721 1754 1784 1813 1842 1872 1901 1930 1959 1989 2018 2047
2077 2106 2135 2165 2190 2219 2249 2278 2307 2336 2366 2395 2424 2454 2463 2512 2541 2554 2571
0.0777 0.0776 0.0775 0.0773 0.0772 0.0769 0.0766 0.0762 0.0758 0.0752 0.0746 0.0740 0.0733 0.0726 0.0719 0.0712 0.0705 0.0699 0.0692 0.0685 0.0678 0.067j 0.0664 0.0657 0.0651 0.0644 0.0637 0.0630 0.0623 0.0616 0.0610 0.0603 0.0600 0.0596
0.1344 0.1342 0.1340 0.1337 0.1335 0.1330 0.1325 0.1318 0.1311 0.1301 0.1290 0.1280 0.1268 0.1258 0.1244 0.1231 0.1219 0.1209 0.1197 0.1185 0.1173 0.1161 0.1148 0.1135 0.1125 0.1114 0.1102 0.1090 0.1078 0.1065 0.1055 0.1043 0.1033 0.1031
284 128
61.8 36.3 23.5 16.4 12.21
9.34 7.43 6.10 5.10 4.31 3.74 3.33 2.90 2.53 2.30 2.07 1.69 1.72 1.57 1.47 1.34 1.24 1.17 1.09 1.02 0.97 0.92 0.88 0.84 0.81 0.80 0.78
108 48.1 23.8 14.0 9.2 6.46 4.85 3.74 3.00 2.48 2.09 1.78 1.56 1.42 1.23 1.08 0.99 0.90 0.83 0.76 0.70 0.66 0.61 0.57 0.54 0.51 0.48 0.46 0.44 0.43 0.41 0.40 0.40 0.39
0.21 0.30 0.42 0.58 0.79 1.1 1.4 1.8 2.4 3.1 3.9 5.0 6.2 7.6 9.6 11.7 14.3 17.3 18.9 20.7
MaaJmomfaoommandad bulk lemparatursa: ?50*F. (3M'C).
Thsaa tfala ara bated upon tamplaa tsatsd in lha laboratory and art not quitonload for all ta/rpias. Wnta us tof ecxnptele salaa apaciftca&ona lor Thsrminol 7S hast tranalar fluid
. fDoaa not conaMult an aapraaa warranty. 6oa NOTICE al front ol this touliatin.
11 15 22 30 41 55 73 95 120 160 200 260 320 400 480 610 740 890 980 1070
t
f 06Li>966
|
TOWOLDMON0039375
WATER_PCB-00023844
Density; Variation With Tcinperature^y^==- ^mMu. s-e^p j
WATER_PCB-00023845
WATER_PCB-00023846
WATER_PCB-00023847
Therminol 75--Pressure Droptjx' Turbulent Flow Inside Clean, Round Tubing and Piping
PRESSURE DROP AP/L, PSI/100 FT @ 750*F
Thtaa data art bastd upon tamplM tastw) In lha laboratory and art not guarantoad lor an tamplta. Writ* ua lor eompiota aalaa apoetteatana lor Thtrminol 75 haai .
tramlar fluid.
tOooi not conaliM* an njxan warranty. So* NOTICE at from o( Ihla bulletin.
.
:
oi597o
|
TOWOLDMON0039379 WATER_PCB-00023848
Therminol 75--Heat Transfer Coefficient^ Turbulent Flow Inside Clean, Round Tubing and Piping
COEFFICIENT hi, BTU/HR-- FT* *F @ TSO*F
0615971
|
TOWOLDMON0039380 WATER_PCB-00023849
MONSANTO INDUSTRIAL CHEMICALS CO./SOO N. LINDBERGH BLVD./ST. LOUIS, MISSOURI 63167 A UNIT OF MONSANTO COMPANY
AKRON. OHIO
CHICAGO, ILLINOIS DETROIT, MICHIGAN LOS ANGELES. CALIFORNIA ST. LOUIS. MISSOURI
260 Springside Drive
9701 West Higgins lid. 30100 Telegraph Hoad 1401 Dove Street
800 N. Lindbergh Blvd.
Montrose Development Park Suite 500
Suite 320
Newport Beach, Calif.
63167
44313
Rosemont, Illinois
Birmingham, Michigan 09m. 9 ?&,%
TbL (3141 694-1000
TW. 12131666-4111
69018 77<f~
.48010
TeJ. (7141 m*sm
Tbll Free 1800) 325-4330
Tel. (312) `
Tel. (313) 645-5420
rrs*- 7160
ATLANTA. CEORGIA
CINCINNATI, OHIO HOUSTON, TEXAS
NEWVorkTnEW YORK
320 Interstate North Parkway Whitehall Bldg.
1300 Post Oak Tower Bldg. 1114 Av>nue of the Americas \/ j/4
Suite 500
8041 Hosbrook Road 5031 Weslheimer Road
1(M)3Jk \.
/>
30339
45236
77056
TrfT (212) 704-5000
Tel. (404>&&&**#
Tfel. 1513) 984-1100
1WI. (713) 877-5999 _ ,
frf-Ti&o
Cutunwr Ord*r l*rei
MIC 9-002
Utho in U.8A ,
O?033