Document 4J49N27Z4qzxNaB5jwEL18G2j

/VLETT hp. PACKARD 6/M^T i 'Appllcafnan rfcie " -S^ ft0* VKS Analysis of Polychlorinated Biphenyls arles A. Burgett and Kathleen D. Basciani, Hewlett-Packard, Avondale, PA 36 % *1 IV'o'eGC 1-73 Summary . Allhough polychlorinated biphenyls (PCB's) have been .widely used for nearly forty years their environmental . impact has only bean studied tinea 1988. Because of tbelr unique thermal properties end chemical inertneaa PCB's may he used as plasticine, flame retardants, and insulat ing fluids in natural and synthetic rubber, floor tile, waxes, electrical transformers, factory coolants, printers Ink, asphalt and adhesives and ratine. With to many and ' varied uses it is easy to understand how PCB's get into the environment. Unfortunately, because of the chemical inertness, once they are Introduced into the ecosystem they Tra extremely persistent chemicals. A recent chemical spill In an estuacy resulted in complete elimination of all the shrimp and drastic reduction in oyster population for three years. Studies [l] on this spill indicate that tha natural river flow Is only reducing tha concentration of the PCB's by 0.35 ppm/yeer. PCB's are also carried through the food chain and concentrated in fatty tissue? of animals and eggs of birds and can slowly build up to lethal doses on long term exposure. The most common PCB's found In the tissues of animals are Aroclor* 1258 'C and 1260. These ere two complex mixtures of PCB's whose total chlorine percentage is indicated in the last two digits of tha Aroclor number. Because the Aroclon ate complex blends they present the chromatogTapher with several unique analysis prob lems. The chromatograms contain many peeks which Span the retention times of the frequently studied chlorinated pesticide; therefore PGB pretence constltatee severe " interference In presttdde residue analysis. Because of the . Jbamber of peeks quantitation becomes difficult; with the Standard methods involving . total area of a retention Window or the peak height of an Intense peak known to he present in the Aroclor blend. .Identification of one f Aroclor In the presence of another becomes almost lmboeslbls because of overlapping compositions, and tha high column temperature requirements of analysis make analysis difficult when low temperature electron capture cells are used. " Although a great deal of Information has been re ' ported about tha analysis of Aroclor blends very Uttle has been reported on the gee chromatography of the In dividual PCB's (2l. This applications note will report a method for the analysis of aqueous Aroclor samples and will illustrate some separations of mixtures of pure PCB's. By using the Model S713A Electron Capture Gas Chrojnefograph higher column temperatures can be used to button the analysis time and picogram analysis can rou tinely be performed. Experimental A K-v.v'.i'U- Psckitd Model 5713.A Gas Chromatogcaph ( equipped .'.i'll a Model 3370B Electronic Digilal Integrator was employed in this analysis. The column used through out this study was a 8 ft x 4mm ID borosilicata glass column packed with 1.5% OV-17/1.95% QF-1 on 80/100 Chromosorb W-HP. The standard solutions wen prepared by weighing the pure PCB's obtained from Analebs, Inc., and dissolving in appropriate volumes with G.CVSpectograde 2, 2, 4- trimethylpentane, (Baker). Solutions of Aroclor 1280 and 1254 wan prepared by dissolving weighted amounts of the pure Aroclor in G.CVSpectograde 2, 2, 4-trtmethylpen- tane. Tha water sample was extracted by taking a 100 ml aliquot of tha simple and transfering It Into a separatory funnel. Approximately 80 ml of 2, 2, 4-lrimethyipentaa* was then added to the separatory funnel. The funnel wee then stoppered and agitated vigorously for 1 minute. After the phases separated the lower aqueous layer was transfered to t second separatory funnel and extracted a sec ond time with another 80 ml portion of 2. 2, 4-trimethyi- pentane. Both organic layers were combined ind tha aqueous layer extracted a third time with 50 ml of Z, 2, V trimethylpentane. The combintd (three) organic layer* war* then filtered through 4" funnel plugged with gloss wool which had been covered with sodium sulfata. Tha filtrate was collected In a Kundema-Danlsh evaporator concen trator and the volume reduced to 5 ml by hasting the apparatus In e 115'C oil bath. Calibration plots for the Individual PCS'! were made by averaging the Integrated- area* of five injections of standard dilutions. The plots were linear for five order* of magnitude. The calibration plots for the Aroclor* wars made by averaging tha peak height for * well resolved In tense peek in each blend and were also linear for five orders of magnitude. Instrumental operating parameters were as follows: MODEL 5713 GC CONDITIONS Column Temperature: Injection Port; EC Detector Temperature; Attenuation: Carrier. Sample Introduced: Recorder 225*0 On column unhealed 300 C As shown (does not ipply It Integrator record, er presentation Is used) Argon-methane 35-8 80 ml/mlr Hewlett-Packard 10 (J syrlngee, all Injections 1.0 ri Hewlett-Packard 7123A. 1 mv full scale, 0.25'Vmio chart spaed DSW 033651 * Ae.-e.-'N* ,,>vN' _ -v, STLCOPCB4017613 1 ft HEXANE SOLVENT Attenuation - 2 4. Calibration plot for Aroclor 1284. WATER SAMPLE EXTRACT 1 at Injection Attenuation -- is 5. Water sample extract showing effective Isolation of Aroclor. oo c Figure 8, impurlttei in "High-Parity'' Hexane. CalcnleHews TUJoTlowingcalculatlon la need to calculate the con- csatiation of PCB's in the original sample. 1 Concentration found from calibration plot " 2880 pico . grama Volume injected " 1 fJ of 5 mi concentrated extract Original sample volume -100 ml 1 ppm - 1 mg/iooo ml H,0 2880 X 10*"jK fi ml . 10.ml 10'1 njl x 109 mri x low^t/L x _ 0.14ppra Refereneee ~c0nrIlr^;,n^AnaMi *'*"* Conteranca, Tallahassee. Florida, July 18, itu by f. porBreaEFlorlda f BTM*te L,llorntory. Sabine Island, Gulf 121 Ccnh,J\ rf 8nd S- S,fB- Bul>- t Environ. Contam. *nd To*., Vo!. 8. (160) 197t. li Printed in U.3.A. OSW 033652 .>v>e` . \ ...- s.' STLCOPCB4017614