Document 45pz6B6jwL2xJ9YmOVeV6p6a
I'tigt) L V>L______
TEXAS STATE DEPARTMENT OK HEALTH
RADIOACTIVE MATERIAL LICENSE
AMENDMENT NO. 5
Piiriuur.t to tii4* Ti*\;is UaJiaLmn Control Act un.l Tc\na Stale Dei:irtm:nt of Health ri-ioilatiuns on radiation, and in reliunco on .statement:! and representation:. bi-i-i-tofon: mode by Lho licon-sno, a license is hereby issued authorizing th.* licoiueu lo receive, urijuire, possess and liau..l'i:c i ;i<l i -Li u1 material listed below; and to use such radioactive materia! for the purpoje(s) anil at the placets) designated below. This license is subject to all applicable rules, reijulalior.s and
orders of tho Texas State Department of HealUt, now or hereafter in effect and to any conditions specified below.
LICENSEE
In accordance with letter dated
July 21, 1970
L Name
Suntide Refining Company
3. License No.
5--322
is hereby amended in its entirei
tAddma Viola Road
to read as follows:
Corpus Christi, Texas
78403
(P. 0. Box 2608)
1. Expiration data
August 31, 197 3
6. Radioactive material (element and mass number)
6. Chemical and/or physical form
7. Maximum amount of radioactivity which licensee may possess at any one time
A. Cobalt 60
A. Sealed Sources A. Six (6) sources not to
(Ohmart Corp.
exceed 15 millicuries eac
Model LAB-238A)
Total: 90 millicuries
8* Authorized use
*
A. To be used in two Ohmart Corporation level detecting assemblies to detect and indicate coke and coke froth level in two coking chambers.
CONDITIONS 9. Unless otherwise specified, the authorized place of use is the licensee's address stated in Item 2 above.
10. The licensee shall comply with the provisions of Part 21, "Standards f Protection A.gainst Radiation" of Texas Regulations for Control of Radiation.
11. Radioactive material shall be used by, or under the supervision of G. E. Ponton, E. A. Pavelka, Bart Cornett or Otis Wilder.
12. The licensee shall not open or remove sealed sources containing radioactive material from their respective source holders.
13. A. Each sealed source containing radioactive material, other than Hydrogen 3, with a half-life greater than thirty days and in any form other than gas shall be tested for leakage and/or contarainatioi at intervals not to exceed six months. In the absence of a certificate from a transferor indicating that a test has beer, made
SUN-85
#S(B) 00073
, io. r h .
TEXAS STATE DEPARTMENT OE HEALTH RADIOAvTIVE MATERIAL LICENSE
Supplementary Sheet
A. '.'a tea
Continued from page 1
LicenM No_______5~*3 2 2 AMENDMENT NO. 5
CONDITIONS
13. A. six months prior to the transfer, the sealed source shall not be p\ into use-until tested.
B. The test shall be capable of detecting the presence of 0.005 microt of removable contamination on the source. The test sample shall b< taken from the sealed source or from the surfaces of the device in which the sealed source is permanently mounted or stored on which < might expect contamination to accumulate. Records of- leak test results shall be kept in units of microcuries and maintained for inspection by the Agency.
C. If the test reveals the presence of 0.005 microcurie or more of removable contamination, the licensee shall immediately withdraw tf sealed source from use and shall cause it to be decontaminated and repaired or to be disposed of in accordance with Texas State Depart of Health regulations. A report shall be filed within five days of receipt of test results with:
Division of Occupational Health and Radiation Control
Texas State Department of Health 1100 West 49th Street Austin, Texas 78756
ATTN: Supervisor, Compliance and Inspection Radiation Control Program,
describing the equipment involved, the test results and the corrective action taken.
14. Installation, relocation, maintenance, repair and initial radiation survey of devices containing radioactive material and installation, replacement and disposal, of sealed sources containing radioactive material used in devices shall be performed only by Ohmart Corporation or other persons specifically authorized by Texas, another Agreement State, or the Atomic Energy Commission.
#S(B) 00074
TEXAS STATE DEPARTMENT OK HEAL'* RADIOACTIVE MATERIAL LICENSE
Supplementary Sheet
Continued from page 2
Liceaaa No.______
AMENDMENT NO. 5
CONDITIONS
15. Except as specifically provided otherwise by this license, the licensee shall possess and use radioactive material described in Items 5, 6 and 7 of this license in accordance with statements representations and procedures contained in application dated May 17, 1963 and letter dated November 13, 1969.
Date.
\
For the Texas Stale Department of Health
Litrnkinn jntl K cki i r*11 >n Radtuliun CwnDai hK(iMn
Supervisor # S (8) 00075
^cpartnirnt of J&altl]
J. . CO^ClanO, m.O. OCPUTY COMMIIIIONCA
AUSTIN, TEXAS
Suntide Refining Company
Viola Road
R. 0. Box 2608
Corpus Christi, Texas
78403
OAAD Of MCAUTH
HAMATOM C. AOAINIOM. M.0.. CNaIKMAN AOS CATO. MON( TO**. N.O., V(CSCm Al AM AN V. KANMKTH TmuAMOmO. Q.O.I.. AICKCTaNV MICKIC <3. MOi.COM*, 0.0, N. L. SAAKS A JA.. M.O.
jess aavns a**t, m, an.
JOHN M. IMITM JA, M.0, NOSLC H. PAICB. M.O. NOrCS e. VtSCMMAKCA, M.S.CMO.
Dear Sir:
We transmit herewith Radioactive Material License No.
5-322. Am. 5
in response to your application initiated on Please note Che conditions on your license.
Julv 21. 1970
Please note that Section 21.403 of the Texas Regulations for Control of Radiation requires telephone and telegraph notification to the Agency of certain incidents. For convenient reference we are supplying the telephone information listed below.
Necessary telephone communication should be directed to a staff member of the Division of Occupational Health and Radiation Control.
Monday through Friday (8:00 a:m. to 5:00 p.m.) 512-454-3781, Extension 241. At other times contact one of these staff members at his residence:
Martin C. Wukasch-------------------- 512-465-5437 Chief, Radiation Control Program
Jack M. Long-------v-....................... 512-452-9714 Supervisor, Compliance and Inspection
David K. Lacker.......... ...................512-295-3026 Supervisor, Licensing and Registration
If necessary, you may request that one of the foregoing be located by contacting:
Texas Department of Public Safety---- 512-452-0331
Sincerely,
Martin C. Wukasch, P.E., Chief Radiation Control Program Division of Occupational Health
and Radiation Control
RC-FL-4
#S(B) 00076
TEXAS STATE DEPARTMENT l/S liiiAi/I RADIOACTIVE MATERIAL LICENSE
Supplementary Sheet
Suntide Refining Company Viola Road Corpus Christi, Texas 78403 (P. 0. Box 2608)
LicenM No-------1 0--322 AMENDMENT NO. 6
In accordance with letter dated December 12, 1972, signed by E. A. Pavelka, License No. 10-322 is hereby amended as follows:
To change Items 3, the license number, front 5-322 to 10-322 as shown above..
To add Part B. to Items 5, 6, 7 and 8 to read:
5. Radioactive material (element and mass number)
6. Chemical and/or physical form
7. Maximum amount of radio activity which licensee possess at any one time
B. Cesium 137
B. Sealed Source
B. One (1) source not to exceed 2 millicuries
8. Authorized use
B. For use in Computer Measurements, Inc. Model 710 Portable Densometer.
To change Condition 11 to read:
11. Radioactive material shall be used by, or under the supervision of, individuals designated by E. A." Pavelka, the Radiation Safety Officer.