Document 44wngeyY67G2ZDNbOxXGVkzap

MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Inspection Date(s): Time: Weather Conditions: Media/Program: Operator Name: Facility or Site Name: Permit ID or Tracking #: SIC Code: Facility Address: (city, state, zip code) Geographic Coordinates: Mailing address: (city, state, zip code) County: Regular Days/Hours of Operation: # of Employees at location: Size of Facility (in acres): Receiving Water(s): Date facility est. @ location: Onsite Representatives: Name: Mike Fickes Authorized Official: Name: Mike Fickes Inspector(s): Page Cirillo (PG Environmental) Sean Ireland (U.S. EPA Headquarters) Heather Dock (Pennsylvania Department of Environmental Protection (PADEP)) Patrick McGee (PADEP) Shawn Lesitsky (PADEP) 2/7/2023 Entry: 1:15 PM Exit: 3:00 PM Cloudy, 33 F Water - CWA 301, 402 - Industrial SW/NEC Warrington Foreign Auto Parts, Inc. Warrington Foreign Auto Parts, Inc. Unpermitted at the time of the inspection 5015 - Motor Vehicle Parts, Used The Facility representative was unsure of the Facility's SIC code. The SIC Code was determined by referencing Dun & Bradstreet, a global business data and analytics company, and was inferred by the Inspector based on the industrial activities occurring at the time of the inspection. 1360 Fickes Road Wellsville, PA 17365 Latitude: 40.045738, Longitude: -76.946254 1360 Fickes Road Wellsville, PA 17365 York County Monday - Friday, 8:30 AM - 5:00 PM 3 Approximately 15 Unnamed tributary to Doe Run 1981 Title: Owner Email: warrfrgnauto@aol.com Contacted? Yes No Title: Owner Email: warrfrgnauto@aol.com Phone: (717) 432-4638 Phone: (717) 432-4638 Title: Inspector Title: Inspector Phone: (720) 743-2093 Phone: (202) 564-2923 Title: Water Quality Specialist Title: Environmental Trainee (Water Quality Specialist) Title: Environmental Trainee (Water Quality Specialist) Phone: (717) 439-5080 Phone: (717) 756-5220 Phone: (717) 705-4700 Page 1 of 6 MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Warrington Foreign Auto Parts, Inc. Inspection Date: February 7, 2023 Inspection Report Author: Name: Page Cirillo (PG Environmental) Supervisor Review: Name: Mark Zolandz (U.S. EPA Region 3) Signature: Date: 3/24/2023 MARK Signature: ZOLANDZ Digitally signed by MARK ZOLANDZ Date: 2023.04.18 12:23:37 -04'00' Date: 4/18/2023 SECTION I - INTRODUCTION Purpose of the Inspection The purpose of the inspection was to determine compliance with the industrial stormwater requirements under 301 and 402(p) of the Clean Water Act and its implementing regulations found at 40 CFR Part 122.26. The inspection was unannounced and consisted of interviewing facility representatives, recording field observations, and taking photographs to document site conditions throughout the facility. Accompanying this report is Appendix A, Aerial Map, and Appendix B, Photograph Log. Opening Conference 1) On February 7, 2023, U.S. Environmental Protection Agency (EPA) contractor, PG Environmental, conducted an unpermitted industrial stormwater inspection at Warrington Foreign Auto Parts, Inc. (Facility) located in Wellsville, Pennsylvania. Page Cirillo of PG Environmental and Sean Ireland of the EPA Headquarters (collectively, the EPA Inspection Team) were accompanied on the inspection by Heather Dock, Patrick McGee, and Shawn Lesitsky of PADEP. Sean Ireland presented his Clean Water Act inspector credential to the Facility representative and conducted an opening conference. The EPA Inspection Team explained the purpose of the inspection was to document the Facility's industrial activity and evaluate the requirement to apply for a National Pollutant Discharge Elimination System Permit (Permit). At the time of the inspection, the Facility did not have coverage under a Permit. Weather conditions at the time of the inspection were cloudy (no precipitation) with temperatures of approximately 33 F. There was no precipitation data available for Wellsville, Pennsylvania. According to precipitation data from Weather Underground1, Harrisburg International Airport did not receive rain the day before the inspection. 2) Credentials presented to: Mike Fickes ______________________________ 1Source: Weather Underground (https://www.wunderground.com/). Page 2 of 6 MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Warrington Foreign Auto Parts, Inc. Inspection Date: February 7, 2023 3) Facility acknowledged receiving previous outreach materials or correspondence on Permit requirements? Yes No Describe: The Facility representative, Mike Fickes, stated the Facility has not received outreach materials or correspondence on Permit requirements. 4) Facility has been individually notified by permit authority or EPA that it is subject to stormwater requirements? Yes No FACILITY'S OPERATION & PRODUCT DESCRIPTION The Facility is approximately 15 acres of outdoor storage for salvaged vehicles. The Facility includes one central building, which operates as the main office and indoor work area and a shed used as an additional indoor work area to the northeast of the main office building. Industrial activities (e.g., salvage vehicle storage) were observed to occur outside throughout the Facility and are exposed to stormwater. The EPA Inspection Team did not inspect the indoor areas of the Facility where industrial activities such as vehicle dismantling, maintenance, and storage may have been occurring. The Facility representative stated that the Facility was no longer purchasing vehicles and that their business was largely comprised of selling the current inventory of parts online. The Facility representative stated that when the Facility was purchasing vehicles, they were drained of fluids indoors. The 5015 SIC code for Motor Vehicle Parts, Used, is consistent with onsite industrial activity. Other industrial facilities owned/operated by same business entity? Yes No SECTION II - OBSERVATIONS FACILITY OBSERVATIONS Pollutant Sources Observations Loading/Unloading Operations The Facility representative stated the Facility was no longer receiving new vehicles at the time of the inspection. Industrial None observed. The indoor areas of the Facility where industrial Manufacturing/ activities such as vehicle dismantling, maintenance, and storage may Processing Operations have been occurring were not inspected by the EPA Inspection Team. Industrial Machinery The EPA Inspection Team observed a skid steer used for moving vehicles located southeast of the main office (refer to Appendix B, & Equipment Storage Photograph Set 3). Storage of Industrial Materials or Products The Facility stores approximately 1,500 salvage vehicles, parts, and scrap metal outside and exposed to stormwater. The parts and scrap metal were located centrally around the main office building (refer to Appendix B, Photograph Sets 2, 3 and 48). The remainder of the Facility was used to store salvaged vehicles. Page 3 of 6 MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Warrington Foreign Auto Parts, Inc. Inspection Date: February 7, 2023 FACILITY OBSERVATIONS Salvage vehicles were stored on pervious ground, adjacent to the unnamed tributary to Doe Run, which runs from the northwest to the southeast (refer to Appendix B, Photograph Sets 14, 15, 21 and 25). Liquid Storage (e.g., Tanks, Liquid Storage Drums) The Facility representative stated that when vehicles were received at the Facility, they were drained of fluids inside the main office/indoor work area. Used oil was retained onsite and burned in a waste oil furnace. The EPA Inspection Team observed six (6) 55-gallon drums located outside the main office building (refer to Appendix B, Photograph Set 2). At the time of the inspection, all the drums were empty and unmarked. The EPA Inspection Team observed one (1) large, uncovered dumpster Waste located in front of the main office building/indoor work area containing Storage/Disposal Areas generic waste. (solid and/or hazardous) The EPA Inspection Team observed trash and debris littered throughout the Facility (refer to Appendix B, Photograph Sets 4 and 30). Waste Treatment Facilities (e.g., None observed. Pretreatment Systems) Fueling Stations/Equipment Maintenance Areas & Cleaning Areas The Facility did not have an on-site fueling station. Sediment & Erosion Controls None observed. Spills/Leaks Handling The EPA Inspection Team did not observe any evidence of spill kits or other spills/leaks handling supplies at the Facility. Temporary (Date Established___________________) Outside Shelters X Permanent The EPA Inspection Team observed one (1) covered shed at the Facility used as an additional indoor work area. Evidence of nonstormwater sources/discharges None observed. (allowable if permitted under MSGP)? Page 4 of 6 MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Warrington Foreign Auto Parts, Inc. Inspection Date: February 7, 2023 Evidence of process wastewater sources/discharges? FACILITY OBSERVATIONS None observed. OUTFALL, STORMWATER DISCHARGE & RECEIVING WATER OBSERVATIONS Number and description of each potential Stormwater Discharge Point from the Facility The Facility is bisected by an unnamed tributary to Doe Run running northwest to southeast. The Facility was observed to slope towards the tributary and did not have controls to divert stormwater runoff away from the tributary. The EPA Inspection Team observed six (6) distinct points of concentrated discharge from the Facility to the tributary (refer to Appendix A, Figure 1). Evidence of pollutants migrating offsite (stains, deposits, ponding) at discharge points, into Receiving Waters or in MS4 The EPA Inspection Team observed unidentified white staining on the rocks within the unnamed tributary to Doe Run (refer to Appendix B, Photograph Set 27). The EPA Inspection Team observed foaming on the water's surface in the turbulent sections of the unnamed tributary (refer to Appendix B, Photograph Sets 12 and 13). Evidence of Nonstormwater Discharges leaving site (authorized or unauthorized) Description of general gradients/slopes onsite, all apparent discharge points, and discharge pathway from Facility to Receiving Water or MS4 (storm drains, channel, swale, ditches, driveway, pipes, & etc.) None observed. The Facility was observed to slope inward, towards the middle of the site and the unnamed tributary to Doe Run, which bisects the Facility. The EPA Inspection Team observed six (6) points of concentrated discharge from the Facility to the unnamed tributary (refer to Appendix A, Figure 1). The majority of the Facility's ground surface was observed to be pervious dirt, except for the area surrounding the main office building and shed. The ground surface of the outdoor area used for storing the salvaged vehicles was grass and dirt. The EPA Inspection Team observed areas of pooled stormwater between the rows of stored vehicles throughout the Facility (refer to Appendix B, Photograph Sets 10, 17, 35, 37, 38, 39, and 43). SECTION III - POTENTIAL AREAS OF CONCERN 1) The EPA Inspection Team observed the storage of salvage vehicles and parts for resale at the Facility, an industrial activity classified under SIC Code 5015 - Motor Vehicle Parts, Used. a. Businesses classified under SIC Code 5015 are regulated under 40 C.F.R. 122.26 for stormwater discharges associated with industrial activity. Page 5 of 6 MULTI-SECTOR GENERAL PERMIT NON-FILER INSPECTION CHECKLIST Warrington Foreign Auto Parts, Inc. Inspection Date: February 7, 2023 b. Industrial activities observed occurring outside and exposed to stormwater at the time of the inspection included the storage of salvaged vehicles and parts. Salvage vehicles were stored on the grass and dirt adjacent to the unnamed tributary to Doe Run. c. The Facility did not have coverage under the Permit at the time of the inspection. 2) The EPA Inspection Team observed unidentified white staining on the rocks within the unnamed tributary to Doe Run (refer to Appendix B, Photograph Set 27). 3) The EPA Inspection Team observed foaming on the water's surface in the turbulent sections of the unnamed tributary (refer to Appendix B, Photograph Sets 12 and 13). 4) The majority of the Facility's ground surface was observed to be pervious dirt, except for the area surrounding the main office building and shed. The ground surface of the outdoor area used for storing the salvaged vehicles was grass and dirt. The EPA Inspection Team observed areas of pooled stormwater between the rows of stored vehicles throughout the Facility (refer to Appendix B, Photograph Sets 10, 17, 35, 37, 38, 39, and 43). There was no precipitation data available for Wellsville, Pennsylvania. According to precipitation data from Harrisburg International Airport there was no precipitation the day before the inspection. SECTION IV - CLOSING CONFERENCE After the site walk, the Facility representative from Warrington Foreign Auto Parts, Inc. was unavailable to meet with the EPA Inspection Team for a closing conference. The inspection concluded at approximately 3:00 PM (EST). SECTION V - LIST OF APPENDICES Appendix A - Aerial Map Appendix B - Photograph Log Page 6 of 6