TITLE: PERSONNEL: OUJECTIVES:
AROCLOR PLANT - ATMOSPHERIC MEASUREMENTS
D. PARKER (D.W.H. CASEY)
.
(i) To develop a suitable method of atmospheric
Aroclor measurement by electron capture gas
chromatography.
.
(2) To recommend a suitable monitoring frequency
SUMMARY:
A known volume of air was drawn through three absorbers, in series, containing hexane. In the laboratory the hexane was analysed for lower Aroclor content by electron capture gas chromatograph
CONCLUSIONS:
All the results obtained were well below the TLV
UcCOMMENDATIONS: 1. Monitoring of Aroclor plant atmosphere to be carried out at yearly Intervals or on request.
2, A more portable and time saving system of sample collection is required, e.g. a G.C. tube.
FUTURE WORK
1. Monitor at yearly intervals in summer months or on request.
2. Develop Improved mthod.
IJI'/YR 7.10.75
D. PARKER MONS 058189
2
1. DETAILS
1.1. Sample Collection
- The absorption train consisted of three 250 nil. absorbers (Drechsel bottles) connected In series and each containing 10O ml. of distilled hexane. It was found that sintered diffusers were better than the column type to prevent hexane carry over.
It was necessary also to Immerse each absorber above the hexane level In methanol/so lid carbon
dioxide mixture at 2C to help present hexane evaporation. To go below this temperature to
0C meant on occasion that any moisture In the air turned to Ice and blocked the diffusers.
Air was drawn through the train by means of a
Millipore pump at about 1 litre/minute and the
flow monitored on a dry gas meter calibrated in
litres. The absorption train stood about 3 feet
above the ground and when sufficient air, initially
about lOO litres then latterly about SO litres,
had been sampled the absorbers viere sealed and
-
removed from the plant to transfer the hexane plus
washings to clean glass flasks. For the first
three sample collections on each site the individual
absorbers were analysed but for consequent
collections they were bulked.
Samples were collected over two periods, October to
December 1974 and July to August 1975. Thus the differing effects of temperature, wind and weather could be taken into consideration.
1.2. Analysis
The collected samples were analysed by Newport Analytical Department. Mrs. A. Tansley also took part in collecting the 1975 samples and was responsible for completing the analysis of these samples in the laboratory.
Using Kuderna Danish evaporators the samples were first concentrated to a known volume of about 5 ml. Dy varying the sample injection size the peaks of the chromatogram were kept in the range of known linearity,
i.e. between 1 and 10 ppm.
Operating londltlons Instrument Column
Detector
Hewlett Packard 402 Cas Chromatograph.
6 mm x 6 ft. glass with 4t OV 225 on 80/100 mesh Chromosorb W, UP.
High temperature Ni63 electron capture cell.
HONS 058190
3
Column Temperature:
170C
Detector Temperature:
230C
Injection Fort Temperature 200C
Pulse Flow Rates:
150
Argon/Methane 61 nl/mln. Helium 120 ml/min.
Range
10
Attenuation
4
Chart Speed
0.25 inches/min.
RESULTS
The following results are from samples collected under differing atmospheric conditions, e.g. the temperaturo range is from 11C to 29C, varying wind force and direction, and wet and dry days. Over the periods of sample collection plant conditions varied also but still the highest result obtained waa 0.25 mg/cubic metre which is well below the TLV of 1 mg/cubic metre for Aroclor 1242 and 0.5 mg/cubie metre for higher Aroclora.
PCB CONTENT OF ATMOSPHERE (mg/cublc metre)
DATE
CONTROL ROOM
4.10.74
11.10.74 24.10.74
8.11.74 15.11.74 22.11.74
29.11.74 3.7.75 10.7.75 17.7.75 24.7.75 14.9.75
21.9.75
0.124
0.043
0.043 0.023
0.072 0.089
0.026
0.222 0.254 0.143 0.104 0.086
0.046
AIR BLOWING ROOM
0.028 0.025 0.029 0.089 0.053 0.196
0.300 0.249 0.070 0.255 0.097 0.196 0.043
, TOTH BIN ARBA
0.023 0.018 0.014 0.033 0.017 0.049
0.028 0.113 0.076 0.119 0.052 0.097 0.030
HONS 058191
4 DISCUSSION The locations at which sampling was carried out were chosen after consultation with plant supervision as to the sltas most likely to cause concern. The method used is effective and reliable but rather time consuming. Improvements in mind involve collection of the sample by drawing loo ml. of air through a short packed column and then introducing the column into the chromatograph. Modifications to the carrier gas system will be needed so that any air in the column can be flushed out by the carrier gas to avoid introducing air into the electron capture detector.