Document 44op7Od0403LJ86bJQMg53ezR

CHUPUND 0 uunMiMi E.' I. du Pont de- Nemours & Company IKUKUttt * Wilmington. Delaware 19898 CENTRAL RESEARCH A DEVELOPMENT DEPARTMENT HASKELL LABORATORY FOR TOXICOLOGY ANO INOUSTKIAL MEDICINE c* F- Reinhardt/B. C. McXusick R. E. Hemingway * `* . ' November 5, 1981 TO: F. A. BOWER - CR&D mm HASKELL LABORATORY J. F. DICKEY LEGAL - D--7083 R. J. GEISEN - C&P -- B-6210 . C. C. GRIFFITH - PHOTO - RSQ-210 . J. R. MARTIN - ER - BOD-1442 T. J. NELSON - FtF -- B-2205 J. C. OLGUIN - PD - N-9504 R. S. PEASE - ENGG - L-1382 R. D. RICHARDSON - BIO - B-13305 M. E. SABLA - TF - N-4420 H. A. SMITH - PPD - WT-642 .. W. L. SPROUT ER N-11400 FROM: S. W. DIXON RES?IRATORS FOR ASBESTOS CONTAINING DUST I have contacted the following respirator suppliers* concerning adequate respirators for asbestos containing dust.* Their comments are summarized below. ` Mine Safety Appliance Company - Wade Miller. American Optical - Earl Shoub.* 3M Company - Ron King. They have no plans to issue a warning letter or label on respirators cautioning against use for asbestos - containing dust such as Norton has done. . They would not recommend against using any respirator for protection against asbestos containing dust which has current NIOSH approval. However, American Optical cautions'that the user should be aware of the recent Occupational Safety and Health Review Commission ruling on the Anaconda Aluminum Case which may require use of a Type "C" supplied-air respirator for certain activities per 29 CFR 1910.1001 (c) (2) (iii). Though Johns Mansville has appealed this ruling to the Fifth Circuit Court of Appeals, this ruling is currently enforceable. * DUP 0913771 I SC-DP-07105 X *%. i>v/nw\( eu ax. x-- 1VUV&TL9&A. 3, X9 0X The high efficiency filters (Type "B") Morton recommends (7580, 7680) are not currently MIOSH approved* for . asbestos.containing dust. * However, MSA has received letters from OSHA and MIOSH saying that it is permissible .to use Type "H" filters for asbestos. None of the suppliers have had testing done for efficiency of their filters for asbestos dust specifically. . However, they contend that it is easier to filter asbestos than the 0.4 0.6 \>m silica dust which MIOSH * has used to test their respiratorsdue to asbestos fiber geometry. * e American Optical*s disposable R1050 respirator which currently has approval for pneumoconiosis and fibrosis producing dusts and mists is currently being submitted for Type "H" and Type "A" (asbestos) approval.. MIOSH*s response will be revealing. . ... '**.. SWD/dar DUP 0913772