Document 44op7Od0403LJ86bJQMg53ezR
CHUPUND
0 uunMiMi
E.' I. du Pont de- Nemours & Company
IKUKUttt
*
Wilmington. Delaware 19898
CENTRAL RESEARCH A DEVELOPMENT DEPARTMENT
HASKELL LABORATORY FOR
TOXICOLOGY ANO INOUSTKIAL MEDICINE
c* F- Reinhardt/B. C. McXusick R. E. Hemingway
*
`*
.
'
November 5, 1981
TO: F. A. BOWER
- CR&D mm HASKELL LABORATORY
J. F. DICKEY
LEGAL - D--7083
R. J. GEISEN
- C&P -- B-6210
.
C. C. GRIFFITH - PHOTO - RSQ-210 .
J. R. MARTIN
- ER
- BOD-1442
T. J. NELSON
- FtF -- B-2205
J. C. OLGUIN
- PD
- N-9504
R. S. PEASE
- ENGG - L-1382
R. D. RICHARDSON - BIO - B-13305
M. E. SABLA
- TF
- N-4420
H. A. SMITH
- PPD - WT-642
..
W. L. SPROUT
ER N-11400
FROM: S. W. DIXON
RES?IRATORS FOR ASBESTOS CONTAINING DUST
I have contacted the following respirator suppliers*
concerning adequate respirators for asbestos containing
dust.* Their comments are summarized below.
`
Mine Safety Appliance Company - Wade Miller. American Optical - Earl Shoub.* 3M Company - Ron King.
They have no plans to issue a warning letter or label
on respirators cautioning against use for asbestos
- containing dust such as Norton has done. .
They would not recommend against using any respirator
for protection against asbestos containing dust which
has current NIOSH approval. However, American Optical
cautions'that the user should be aware of the recent
Occupational Safety and Health Review Commission ruling
on the Anaconda Aluminum Case which may require use
of a Type "C" supplied-air respirator for certain
activities per 29 CFR 1910.1001 (c) (2) (iii). Though
Johns Mansville has appealed this ruling to the Fifth
Circuit Court of Appeals, this ruling is currently
enforceable.
*
DUP 0913771 I SC-DP-07105
X *%. i>v/nw\( eu ax.
x--
1VUV&TL9&A. 3, X9 0X
The high efficiency filters (Type "B") Morton recommends
(7580, 7680) are not currently MIOSH approved* for
.
asbestos.containing dust. * However, MSA has received
letters from OSHA and MIOSH saying that it is permissible
.to use Type "H" filters for asbestos.
None of the suppliers have had testing done for efficiency
of their filters for asbestos dust specifically.
. However, they contend that it is easier to filter
asbestos than the 0.4 0.6 \>m silica dust which MIOSH *
has used to test their respiratorsdue to asbestos fiber
geometry.
*
e American Optical*s disposable R1050 respirator which
currently has approval for pneumoconiosis and fibrosis
producing dusts and mists is currently being submitted
for Type "H" and Type "A" (asbestos) approval.. MIOSH*s
response will be revealing.
.
... '**..
SWD/dar
DUP 0913772