Document 44o7bJZOqGorJRwpeOxrEO59V
I' Heating Systems Hot wafer
Triplex Heating Specialty Co., Inc.
242-268 Grant St.
Peru, Indiana
HOT WATER SYSTEMS AND SPECIALTIES
DIRECT DRIVE AQUALATOR
A most powerful Circulator. The design of the pump proper is the result of years of experiments. It will deliver water against an II ft head--about twice as powerful as direct driven pumps. The trouble-free coupler combined with the unique stuffing box assures lasting service. The Circulator is lubricated, protecting the bearings and stainless steel shaft. Every motor is protected with an automatic overload switch and meets all states, electrical codes.
Direct Drive
No.
Size
60 Cyc. 110V Motor Size
22D vs
1/8 R P.
23D r
1/8 R P.
24D 1 vs
1/6 R P.
25D IVS
1/6 H. P.
26D 2"
1/6 R P.
SIZES AND CAPACITIES
Circulator R. 5. M.
1750
1750 1750 1750 1750
Rad. Cap. Sq Ft 300 500 800
1200 2000
Storage Tank Cap.
500 gal.
1000 gal. 1500 gal.
2000 gal. 2000 gal.
Cals. Max. Per Min Head
20 138' 25 138' 35 138' 50 138' 75 138'
End to End
ssrs
6VS &/S 83zs
83/,'
Ship. Wt.
55 55 60
60 65
THERMOLATORS
Straight Type Flow Control Valve
Only one Flow Control Valve is. required in a properly balanced Flow Control System. For best operation, the air should be eliminated from the boiler and carried directly to the expansion tank. The Anti Gurgle Fitting shown in the bottom of the Flow Control Valve pqsitively accomplishes this. TRIPLEX Flow Control Valves have a convenient lever handle to set the valve for emergency or seasonal operation. The Anti Gurgle Fitting is not inlcuded with the price of the Thermolator.
No.
Size
Width
Height
Sq Ft Rad. | Ship. wt.
123 1' 4' 4'
500 |
4
124 v/S 5'
y/s
800 |
9
125
IVY
5vs
8VS-
1200 |
11 .
126 2'
6'
9vs
2000 |
15
127
3' . 63/Y
9vs
5000 |
28
Angie Type Flow Control Valve
No. 127 is not an angle type. When ordering specify straight or angle type.
SIZE INCHES No. of System Sq Ft Rad.
FLOW CONTROL SYSTEMS COMPLETE
3/4' P. 1' FCV 1' P. 1' FCV W P. I'A'FCV Wi P. W FCV 2' P. 2' FCV 3' P. 3' FCV
22-3-501
23-3-502
24-4-503
25-5-503
26-6-504
27-7-5044
300 500
800
1200
2000
5000
982
Triplex Healing Specialty Co., Inc.
Heating Systems H`Water
TRIPLEX DISTRIBUTOR and AIR ELIMINATOR FITTINGS
1 1 ________ o-nnmirrAOC
Main
r
w ws
Run
VS *
1' X 1'
WSrtWS
|I/i'l'//
1
Outlet
vs
1/2' or *4'____
V20 OT J/4'
1
'/z'oryv
Ship. Wt.
1 lb.
IVi lbs.
2 lbs.
3 lbs.
CUT OPEN VIEW OF TMfiE* distributor
TRIPLEX DISTRIBUTOR
Circulating fittings for one pipe systems. Efficiency comparable to a two pipe system. Only one fitting per radiator, except where basement radiators are in
stalled which require two Distributors. By closing a radiator valve the full area of the main is bypassed through the fitting to the balance of system.
common tee
TRIPLEX DISTRIBUTOR
SAFE-T BOILER PLUG
OETAIL OF- DISTRIBUTOR INSTALLATION
Positive relief from dan
AIR ELIMINATOR
gerous pressures. Includ A positive method of per
ed with Flow Control manently eliminating air from
Systems (complete), concealed copper or cast iron
Tank-in-Basement Sys radiator after the system is
tems, No. 7 and 8 Con vented the first time. Sizes
trol Units. Breakages of 1 to 3 in. boiler from excessive
pressure eliminated and
No.
Break. Pres.
Breaking Bars
Dia- Dimensions Ship.
phragms Wd.
Ht.
Dia.
Wt.
36 40 lbs- Wht. Iron Lead 33/2 *3/2 33/2 3 lbs.
37 75 lbs. Wht. Iron Lead 33/2 4>/2 33/2 3 lbs.
38 100 lbs. Wht. Iron Lead 33/2 4'/2 33/2 3 lbs.
39 125 lbs. Wht. Iron Lead 33/2 4>/2 3Vi 1 3 lbs.
reduced with the Pressure Reducing Valve. The
TRIPLEX CONTROL UNITS
fast-filling feature will save the cost of the unit in time saved filling the system. The
Easily installed. All water strained as it enters system. Strainer cast integral with Pressure
Relief Differential Type Valve, seating under water and has lever for testing and flushing. Check is
Reducing Valve. Proper amount of water main tained in the system and the city water pressure
between
wiwku
Relief
a--nd -P--r-e--s-s--u--r-e---R--e- ducing
Valves.
No. 7 CONTROL UNIT is a positive protection against boiler breakages
from pressure. It consists of a No. 15 unit and No. 36 (40 lb) Safe-T Boiler Plug*
Dimensions
Ship.
No. Tapped Body
Diaphragms
Springs
Length
Ht.
Dia.
Wtr-
W R. P. Iron V/ R. P. Iron w R. P. Iron w R. Brass " Vi' R. P. Iron
Vf R. P.Iron
Bronze Bronze Bronze Bronze Bronze Bronze
Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl.
ioy>* \w v/s'
W 9>/4'
w w 63/8'
63/fl'
w y/s iVS y/s y/s
y/s
9'A lbs. l2/4 lbs. P/4 lbs..
7 lbs. 103/4 lbs.
7V2 lbs.
983
v/