Document 44o7bJZOqGorJRwpeOxrEO59V

I' Heating Systems Hot wafer Triplex Heating Specialty Co., Inc. 242-268 Grant St. Peru, Indiana HOT WATER SYSTEMS AND SPECIALTIES DIRECT DRIVE AQUALATOR A most powerful Circulator. The design of the pump proper is the result of years of experiments. It will deliver water against an II ft head--about twice as powerful as direct driven pumps. The trouble-free coupler combined with the unique stuffing box assures lasting service. The Circulator is lubricated, protecting the bearings and stainless steel shaft. Every motor is protected with an automatic overload switch and meets all states, electrical codes. Direct Drive No. Size 60 Cyc. 110V Motor Size 22D vs 1/8 R P. 23D r 1/8 R P. 24D 1 vs 1/6 R P. 25D IVS 1/6 H. P. 26D 2" 1/6 R P. SIZES AND CAPACITIES Circulator R. 5. M. 1750 1750 1750 1750 1750 Rad. Cap. Sq Ft 300 500 800 1200 2000 Storage Tank Cap. 500 gal. 1000 gal. 1500 gal. 2000 gal. 2000 gal. Cals. Max. Per Min Head 20 138' 25 138' 35 138' 50 138' 75 138' End to End ssrs 6VS &/S 83zs 83/,' Ship. Wt. 55 55 60 60 65 THERMOLATORS Straight Type Flow Control Valve Only one Flow Control Valve is. required in a properly balanced Flow Control System. For best operation, the air should be eliminated from the boiler and carried directly to the expansion tank. The Anti Gurgle Fitting shown in the bottom of the Flow Control Valve pqsitively accomplishes this. TRIPLEX Flow Control Valves have a convenient lever handle to set the valve for emergency or seasonal operation. The Anti Gurgle Fitting is not inlcuded with the price of the Thermolator. No. Size Width Height Sq Ft Rad. | Ship. wt. 123 1' 4' 4' 500 | 4 124 v/S 5' y/s 800 | 9 125 IVY 5vs 8VS- 1200 | 11 . 126 2' 6' 9vs 2000 | 15 127 3' . 63/Y 9vs 5000 | 28 Angie Type Flow Control Valve No. 127 is not an angle type. When ordering specify straight or angle type. SIZE INCHES No. of System Sq Ft Rad. FLOW CONTROL SYSTEMS COMPLETE 3/4' P. 1' FCV 1' P. 1' FCV W P. I'A'FCV Wi P. W FCV 2' P. 2' FCV 3' P. 3' FCV 22-3-501 23-3-502 24-4-503 25-5-503 26-6-504 27-7-5044 300 500 800 1200 2000 5000 982 Triplex Healing Specialty Co., Inc. Heating Systems H`Water TRIPLEX DISTRIBUTOR and AIR ELIMINATOR FITTINGS 1 1 ________ o-nnmirrAOC Main r w ws Run VS * 1' X 1' WSrtWS |I/i'l'// 1 Outlet vs 1/2' or *4'____ V20 OT J/4' 1 '/z'oryv Ship. Wt. 1 lb. IVi lbs. 2 lbs. 3 lbs. CUT OPEN VIEW OF TMfiE* distributor TRIPLEX DISTRIBUTOR Circulating fittings for one pipe systems. Efficiency comparable to a two pipe system. Only one fitting per radiator, except where basement radiators are in stalled which require two Distributors. By closing a radiator valve the full area of the main is bypassed through the fitting to the balance of system. common tee TRIPLEX DISTRIBUTOR SAFE-T BOILER PLUG OETAIL OF- DISTRIBUTOR INSTALLATION Positive relief from dan AIR ELIMINATOR gerous pressures. Includ A positive method of per ed with Flow Control manently eliminating air from Systems (complete), concealed copper or cast iron Tank-in-Basement Sys radiator after the system is tems, No. 7 and 8 Con vented the first time. Sizes trol Units. Breakages of 1 to 3 in. boiler from excessive pressure eliminated and No. Break. Pres. Breaking Bars Dia- Dimensions Ship. phragms Wd. Ht. Dia. Wt. 36 40 lbs- Wht. Iron Lead 33/2 *3/2 33/2 3 lbs. 37 75 lbs. Wht. Iron Lead 33/2 4>/2 33/2 3 lbs. 38 100 lbs. Wht. Iron Lead 33/2 4'/2 33/2 3 lbs. 39 125 lbs. Wht. Iron Lead 33/2 4>/2 3Vi 1 3 lbs. reduced with the Pressure Reducing Valve. The TRIPLEX CONTROL UNITS fast-filling feature will save the cost of the unit in time saved filling the system. The Easily installed. All water strained as it enters system. Strainer cast integral with Pressure Relief Differential Type Valve, seating under water and has lever for testing and flushing. Check is Reducing Valve. Proper amount of water main tained in the system and the city water pressure between wiwku Relief a--nd -P--r-e--s-s--u--r-e---R--e- ducing Valves. No. 7 CONTROL UNIT is a positive protection against boiler breakages from pressure. It consists of a No. 15 unit and No. 36 (40 lb) Safe-T Boiler Plug* Dimensions Ship. No. Tapped Body Diaphragms Springs Length Ht. Dia. Wtr- W R. P. Iron V/ R. P. Iron w R. P. Iron w R. Brass " Vi' R. P. Iron Vf R. P.Iron Bronze Bronze Bronze Bronze Bronze Bronze Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. Bz. & R. P. Stl. ioy>* \w v/s' W 9>/4' w w 63/8' 63/fl' w y/s iVS y/s y/s y/s 9'A lbs. l2/4 lbs. P/4 lbs.. 7 lbs. 103/4 lbs. 7V2 lbs. 983 v/