Document 44aKp1yRzp66Ro5nQ8NoY2y2R

Heating Systems Specialties Armstrong Machine Works 8S1 Maple Street, Three Rivers, Mich. Steam Traps ... Air Traps . . . Humidifiers High Side Floats . .. Refrigerant Purgers Representatives in Principal Centers ARMSTRONG INVERTED BUCKET STEAM TRAPS Armstrong offers a complete line of traps for draining low and high pressure steam headers, pipe-coil radiation, unit heaters, air conditioning equipment, process equipment, etc., to gravity or vacuum return systems. Automatic Air Discharge. Standard traps automatically discharge normal amounts of air along with condensate. Where large amounts of air must be vented quickly when steam is first turned on, Armstrong BLAST Traps with thermic bucket vents are recommended. Air handling capacity ranges from 500 to 1500 cu ft free air per hour. . Side Inlet Traps_ Pipe Connections........................... List Price (Regular)..................... List Price (Blast Trap)............... Telegraph Code (Regular)........ Telegraph Code (Blast Trap).. Height.............................................. Diameter.......................................... Number of Bolts............................ Diameter of Bolts.......................... Weight................................................. Maximum Pressure, lbs. Continuous dis charge capacity in lb of water per hour at pressure indi cated. For more complete informa tion see the Capa city Chart in Arm strong Steam Trap Book. 5 10 15 20 30 50 70 100 125 150 200 250 Bottom Inlet Traps Pipe Connections........................... List Price (Regular).................... List Price (Blast Trap)............... Telegraph Code (Regular)-. Telegraph Code (Blast Trap). Height................................................ Diameter......................................... Diameter of Bolts......................... Number of Bolts........................... Weight.......................... ................ Maximum Pressure, lb.............. H' or H` $7.00 18.50 Aloe Aloette SHm 5' 6 y ibs. 125 450 560 640 690 500 580 660 640 680 No. 812 No. 813 CAPACITIES, PRICES W or Hw K'ortf' H" or 1' DIMENSIONS $10.00 $16.00 $22.00 Note that capacities of $11.50 $18.00 $24.00 No. 811, 812 and 813 Brown Cherry Dawn traps are the same as Brownette Cherette Dawnette No. 211, 212 and 213 re 6X' 896' uy spectively. On most in-- . 5' 6H' 7VaT stallations, the engineer 6 6 6 therefore has a choice of y W M' side inlet--side outlet 5M lbs 13M lbs. 25 lbs. or bottom inlet--top 250 250 230 outlet body styles. 950 1060 880 1000 840 950 860 950 810 1600 1900 2100 1800 2050 1900 2200 1800 2000 1500 1600 1300 2900 3500 3900 3500 4000 4100 3800 3600 3900 3500 3200 ' 3500 4800 5800 6500 6000 6800 6300 6000 6200 6700 5700 5300 5700 7600 9000 10000 8500 9800 9000 9200 10400 10900 9500 9200 7000 14500 17300 19200 18500 18000 18200 18300 18000 20000 18500 17500 19000 No. 211 W $ 9.25 $10.75 Aspen Aspette y 6 m ib 250 No. 212 W or *A` $15.00 $17.00 Birch Birette 8' 5' y 8 10H lb 250 No. 213 y or h $20.75 $22.75 Walnut Walette 10y W y 6 19 lb 250 yNo. 214 No. 215 lr i' or i ' $29.00 $38.00 $31.50 $40.50 Hemlock Larch Hemlette Larette 12M' iy y 8 14' 8y y 8 32 lb 47 lb 250 250 No. 216 Xy or V $55.00 $60.00 Tamarack Tamrctte 16H ioy y 12 801b 250 1346 Armstrong Machine Works Heating Systems sj>eciaities High Capacity, Compact Size- The high leverage of the patented free-float ing lever makes it possible to open dis charge orifices which are very large for over-all trap size. Positive Action. The discharge valve is either wide open or closed tight. Fast opening and closing prevent wire-draw ing. Self-Cleaning. Swirling action of con densate during discharge carries dirt through trap. There are no dead spots for dirt to collect. High Quality. 18-8 stainless interior parts. Valve and seat are chrome steel, hardened, ground and lapped. Low pressure trap parts same material and quality as those used for 1500 psi, 900 F. Armstrong Steam Trap Book. 36 pages of dataon traps, selection, instal lation and maintenance. A usable hand book for any engineer dealing with traps. Free copy on request. TRAPS FOR UNIT HEATERS Armstrong inverted bucket steam traps are particu larly suitable for draining low or high pressure unit heaters to vacuum or gravity return systems for the following reasons: i 1. Air and COj are vented automatically every time the trap opens--this keeps heaters hot, helps pre vent corrosion. 2. Condensate is discharged at steam temperature as rapidly as it accumulates--keeping heaters at max imum temperatures. 3. Leakage of steam through an Armstrong trap in proper working condition is impossible ... no build-up of back pressure in return lines. 4. The dependability of Armstrong traps is outstand ing--they seldom require maintenance. A New Bulletin containing Btu output figures for 24 makes of unit heaters explains fully how to select traps for this service. A valuable compilation that is available to anyone upon request. ARMSTRONG STEAM HUMIDIFIERS For Stores, Offices, Hospitals. Factories, Laboratories Operation. These units provide auto matic, closely con trolled humidification by introduction of steam directly into the atmosphere. In stallation is compara ble to that of unit heaters. Steam at 15 psi or less is required. A solenoid discharge valve on the hu midifier is controlled by a sensitive humidistat. A fan mounted on the humidifier aids in steam dispersal, or a venturi nozzle can be supplied. Where an electric spark might represent an ex plosion hazard, compressed air operated models are available. In addition to the unit humidifier illustrated, there is a large model for installation in large air ducts and central heating systems. Capacities range from 31 to 630 lbs of steam per hour. Advantages. Installation cost of Arm strong Humidifiers is as much as 80 per cent less than some types of equipment. The small C-2 unit lists at $120.00 com plete with fan and motor, humidistat, strainer and steam trap. Operation, us ing steam at around $1.00 per ton, is economical. There is no extra load on the heating system. No dripping--any moisture in the steam is re-evaporated in the steam-jacketed separating cham ber. Control is accurate within a few per cent R. H. Bulletin No. 1772 gives complete data on required relative humidities, selec tion and installation of Humidifiers. All Armstrong products are sold on a basis of satisfaction or your money back. 1347