Document 44OM6m18NoxeggYzRBp1nRkNx
AMBIENT AIR VCM MONITORING GRAB SAMPLES - CHARCOAL TUBE SAMPLES
1974
/V
Total No. Samples ND (None Detected) > ND, <0.5 ppmv >0.5 ppmv, <1.0 ppmv >"1.0 ppmv
i
Total No. Samples ND (None Detected) > ND,< 0.5 ppmv >0.5 ppmv ,<1.0 ppmv ^1.0 ppmv
Total No. Samples ND (None Detected) > ND, <0.5 ppmv >0.5 ppmv,<1.0 ppmv >"1.0 ppmv
Fence Line
65 57
8 None None
47 46
1 None None
Community
128 119
9 None None
178 173
5 None None
Fence Line
Community
2 None
2 None None
11 10
1 None None
1975
29 25
4 None None
37 30 17 None None
1976 (Charcoal Tube Samples Only, 4 Hrs. Duration)
24 20
4 None None
30 29
1 None None
1. Grab samples collected in 50 ml syringes and analyzed by directed injection in GC (FID)
2. Charcoal Tube samples collected by battery powered pumps, desorbed by solvent extraction then analyzed by GC (FID).
3. Sensitivity of methods (1) and (2) is approximately 0.05 ppmv. Hence, ND (None Detected) is less than 0.05 ppmv.
UCC 103933
COMMUNITY AMBIENT AIR VCM MONITORING
GRAB SAMPLES
Total No. Samples ND (None Detected)
y ND,<0.5 ppmv
>0.5 ppmv,< 1.0 ppmv
>1.0 ppmv
128 119
9 None None
Total No. Samples ND (None Detected) > ND, < 0.5 ppmv >0.5 ppmv ,<1.0 ppmv >1.0 ppmv
178 173
5 None None
Total No. Samples ND (None Detected) > ND,< 0.5 ppmv >0.5 ppmv ,<1.0 ppmv
>1.0 ppmv
Grab Samples Discontinued
1974 1975 1976
CHARCOAL TUBE SAMPLES
11 10
1 None None
37 20 17 None None
30 29
1 None None
1. Grab samples collected in 50 ml syringes, analyzed by direct injection in GC (FID).
2. Charcoal tube samples collected by battery powered pumps for minimum of 4-hour durations Desorption of any existing VCM by solvent extraction then analyzed by GC (FID).
3. Sensitivity in methods described above is approximately 0.05 ppmv. Hence, ND (None Detected) is less than 0.05 ppmv.
UCC 103934
UCC 103935
October, 1975 Total No. Samples Average, ppmv Std. Dev. of Avg. No. Times >25 ppmv
November, 1975 Total No. Samples Average, ppmv Std. Dev. of Avg. No. Times >25 ppmv
December, 1975 Total No. Samples No. Times >25 ppmv
January, 1976 Total No. Samples Average, ppmv Std. Dev. of Avg. No. Times > 5 ppmv No. Times >25 ppmv
February, 1976 Total No. Samples Average, ppmv Std. Dev. of Avg. No. Times >5 ppmv No. Times ^25 ppmv
March, 1976 Total No. Samples Average, ppmv Std. Dev. of Avg. No. Times >5 ppmv No. Times >25 ppmv
AMBIENT AIR MONITORING SEQUENTIAL SAMPLING - VAPOR FRACTION ANALYZER
NORTH CHARLESTON DISTRIBUTION CENTER
FENCELINE - NORTH OF UNLOADING RACK
No. 1 - West
No. 3 - Center
1116 0.3
1.0
1
1116 0.2
1.0 1
1080 0.3 0.3
None
1080 0.2 0.2
None
/
1116 None
1116 None
900 0.3 0.5
None None
900 0.2 0.3
None None
972 0.2 0.5 2
None
972
0.1 1.1 1
1
1080 0.1 0.5
2 None
1080
0.0 0.3
None None
No. 5 - Bast
1116 52
37 1
1080 12 44
16
1116 16
900 16 34
71 i5
972 12 42
63 23
1080 0 .7 2 .9
38 5
April, 1976 Total No. Samples
No. Times 5 ppmv No. Times 25 ppmv
AMBIENT AIR MONITORING (cont.)
No. 1 - West
No. 3 - Center
730 2
None
730 2 1
No. 5 - East
730 16 2
W. C.Young 4/23/76
V
UCC 103936