Document 44GmN2LKyDyEM8VJ1JEdGb0Xj
Inspection Report Mechanical Integrity Test Osage DNR / Environmental Protection Agency 1201 Elm Street, Suite 500
Dallas TX 75270
Inspector Matthew Allen
MIT Date 10/07/2024
Operator Representative Performance Energy Resources, LLC Report Sent Operator
Inject Interval Multiple
USDW 309
Annulus Fluid Type oil
Concentric Pkr
Casing 5.5
Tubing 2.88
Time 11:30
Well Type Disposal Packer Depth 1488
Operator Info
Performance Energy Resources, LLC P.O. Box 628 Barnsdall, OK 74002 Phone: 918-847-2531
Inventory ID API Well No Lease Name
Well ID
OS6001000
PERRIER 2
Location NE 30 25N 12E
Type of MIT Injecting MIT Due
Casing - Tubing Annulus Pressure
Y
Injection Rate (bpd)
04/01/2024
MIT Freq
Test Reason Routine Tubular Lining EVERY FIVE YEARS
Ann Filled (hrs) Ann Press Mont
Time
Pre-Test Initial Mid Final
11:30 11:45
12:00
Tubing Pressure 30
30 30
30
Annulus Pressure 0
210 215
215
Flowback Pressure
High 215 Mid 100 Low 20 End 0
Total Volume
Volume
2000 1100 400 3500
ADA Pressure Test - Required Test Pressure (Fluid Column Ht * Specific Gravity * .433 / N2 Wt Fac =
Required Test Pressure)
Depth to Top Perf/Open Hole Depth to Fluid Level Fluid Column Level
Specific Gravity of Fluid
Tubing
Annulus
Nitrogen Weight Factor
Required Pressure Test
Remedial Action Type
Fluid Migration Test Type
Inspection Comments Inspector Signature
Remedial Action Type Pressure hold OK. Annulus flowback was 100% crude oil.
MATTHEW ALLEN Date: 2024.10.07 15:27:59 -05'00' Digitally signed by MATTHEW ALLEN
Supervisor Signature JEANNE ECKHART Date: 2024.10.09 07:22:59 -05'00' Digitally signed by JEANNE ECKHART