Document 41rRE9wBL3vm0wdD6oO5yreQ
ASBESTOS"STAKE IN DU PONT
Employee Health Removal Cost Liability Management
DVr 0909346
DU 029008
i proposal)
-C
"Asbestos" is an issue for which ERC should have value.
Form Asbestos Focus Group (utilizing Asbestos Issues Committee and ERC Liaison).
Review "Asbestos" issues outlined by A.I.C. and determine:
- If issues outlined are the right ones to work on.
If groups identified to lead particular issue are right groups.
DUf 0909347
DU 029009
CORPORATE (ERC/AIO
Q Develop policies, practices, ete. (or Du Pont
Develop Inspectlon/sssesement guidelines for
j
comprehensive program (document practices end options !
for EPA Nethaps compliance).
Maintain network of resources throughout the Company.
Redefine and continue lab QAJQC program.
Maintain Corporate Respirable Fibers System.
Update bueinesees/regions/sites on changes In regulation*
and best practices.
MLS
Develop removal/contraeting best practices administration guideline.
Develop Integrated quality/cost abatement supplies program.
Review and resolve contractor liability Insurance Issue.
! j
BUSINESS
Q Provide consultation and orvslte inspection/management assistance to sltss (options: Fibers, TIMS, MLS/vendora).
i
Manage their own own asbestos program and coordinate training specific to their site.
DUr 0909348
DU 029010
PLANNING FOR THE INSPECTION REVIEW OF PREVIOUS INSPECTION RECORDS AND BUILDING DRAWINGS
1. Scheduling of the Inspection 2. Obtaining Access 3. Building Record Review 4. Probable Homogeneous Areas According to
Drawings 5. Consultation with Maintenance and Operations
Personnel 6. Previous Inspection and Sampling Reports 7. Previous Abatement Records 8. Maintenance Records 9. Exclusions for Previously Performed Inspections
(763.99) 10. General Planning Comments
DUP 090*445
DU 029011
1. SCHEDULING THE INSPECTION
Nights Weekends Business hours School hours Contract
DU 0909466
DU 029012
2. OBTAINING ACCESS
Locks (keys) Ladders/Lifts (Safety!!) "Unused" or "Unimportant" spaces Inaccessible spaces Unknown spaces (dimensional accountability) Contract
DU* 0909467
DU 029013
uiilBlMaMtoJtMnWi--aiiwiM*
3. BUILDING RECORD REVIEW
Drawings
Specs
Construction contract
Bid documents (alternates)
Change orders
Pay requests (dates)
Construction field reports
Maintenance records
Original construction
Additions/Renovations
OUr 090944*
DU 029014
4. PROBABLE HOMOGENEOUS AREAS ACCORDING TO DRAWINGS
Design drawings
Contract document drawings As-Built drawings
Shop drawings (Hyatt disaster) Floor plans Sections
Finish schedule
Mechanicai/Plumbing/Electrical
Structural
DU 0909449
DU 029015
5. CONSULTATION WITH MAINTE NANCE & OPERATIONS PERSONNEL
Maintenance procedures Maintenance schedules Operations procedures Operations schedules M/P/E design/location/operation "Unused" or "Unknown" spaces Passed ACM disturbance Current ACM procedures 0 & M procedures? Management sophistication Employee sophistication
DUf 0909470
DU 029016
6. PREVIOUS INSPECTION AND SAMPLING REPORTS
Location and pattern of samples?
Number of samples?
Composition of samples?
Condition of ACM?
Type and use of ACM?
Other data applicable to AHERA
Assessment categories and your assessment methodology?
Must be field verified
Do exclusions apply?
Are some samples applicable?
Must the entire survey be redone?
How was nonfriable ACM addressed?
Was any suspect ACM indicated?
DUP 0909471
029017
7. PREVIOUS ABATEMENT RECORDS
Location Methods Disposal Clearance criteria Worker training Residual contamination? Urgent response action needed? Special cleaning needed?
CUV 0909472
\y\5 029018
IWMWMiaiMHiHIMIMMlKKaBWSBiBWMB!-tt IMiMliilWalM
8. MAINTENANCE RECORDS
HVAC filter changes TSI disturbance O & M procedures? Schedules Routines Emergency
OUr 0909473
DU 029019
9. EXCLUSIONS FOR PREVIOUSLY PER FORMED INSPECTIONS (763.99)
For homogeneous areas or sampling areas Friable ACBM was identified Nonfriahle ACBM was identified No ACBM is present (inspector) No ACBM is present (lead agency) Suspect ACBM is assumed ACM All ACBM has been properly removed No ACBM specified or used
Must assess friable Has nonfriable become friable? Must assess newly friable
READ THIS SECTION 11
DO 0909474
DU 029020
10. GENERAL PLANNING COMMENTS
2 major divisions of suspect ACBM Accessible Space Inaccessible Space
Assumptions Building conditions Survey Conditions
009 0909475
DU 029021