THE DOW CHEMICAL COMPANY LOUISIANA DIVISION POWER & UTILITIES DEPARTMENT INTRODUCTION The Power & Utilities Department of the Louisiana Division is responsible for the safe and economical operation of its assigned facilities and for seeing that they are adequately maintained. Their facilities are as follows: Power Plants Water Treating Plants and Distribution System Sewage Treating Plant and Collection System River Water Pump Station and Supply Canals Return Water Pump Station and Return Canals General Plant Piping and Pipeways Electrical Distribution System Including Substations Street Lighting Fuel Gas Stations and Distribution System (In-Plant) Fuel Oil Storage and Distribution Water Wells Nitrogen Distribution Carbon Dioxide Distribution Oxygen Distribution Rev 1/80 DO 1?4478 CONFIDENTIAL Page 40 POWER GENERATION AND DISTRIBUTION The Louisiana Division Power Plant No. 1 generates and distrubutes all its electrical power and steam. Steam is generated at 1250 psig and is extracted for process from three single automatic and one double auto matic extraction turbine. Distribution pressures are 475 psig and 235 psig. Electrical power is generated at 14.4 KV and is distributed at this voltage to Chlorine rectifiers, motor power substations, and river water pump stations. Excitation for the Generators 1 and 2 is by means of motor generator sets with a full capacity spare exciter available for use. This method of excitation allows for easy maintenance of commutators. Generators 3 and 4 are provided with static exciters with provisions for using the spare motor-driven exciter. Steam Turbine-Generator Statistical Data Turbines No. 1 No, 2 No, 3 No. 4 Make KW Throttle Press. & Temp. Throttle Flow 475 psig Ext. Flow 235 psig Ext. Flow G. E. 50,000 1250/950 l,060,000#/Hr. 700,000 200,000 G. E. 60,000 1250/950 1,250,000#/Hr. -1,000,000 G. E. 60,000 1250/950 1, 250,000///Hr. -1,000,000 G. E. 50,000 1250/950 1,250,000#/Hr 1,200,000 Generators KVA @ 30 psig Hydrogen 58,824 Capability (KW) 55,000 88,235 90,000 105,000 85,000 Condensers Make Heat Transfer Area Allis-Chalm. Worthington Worthington 30,000 sq. ft. 40,000 sq. ft. 40,000 sq. ft. Exciters Motors No. 1 No. 2 Spare No. 3 No. 4 Make HP RPM Volts G. E. 300 1190 2300 G. E. 380 1190 2300 G. E. 300 1190 2300 G. E. Static G. E. Static Generators KW Volts Amps 200 250 800 250 250 1000 200 250 800 00 174479 GONFTDFNTIAl Rev. 1/80 Page 41 GAS TURBINE-GENERATOR AND AUXILIARIES Statistical Data Turbines Make: Model: Rated Power: Turbine shaft speed: Fuel: Generator Rating: Cooling: Westinghouse W-191G 16,470 KW Peak Load 15,290 KW Base Load 4,912 RPM Natural gas or fuel oil 16,320 KW @ 0.85 power factor 19,200 KVA, 3-phase, 60 cy., 900 RPM 13,800 volts Open, air cooled Exciter Direct connected, open air cooled Rating: 100 KW, 125 volt DC Starting Unit Make: Model: Fuel: HP: Number cylinders Allis-Cha Inters 25000 Diesel 250 6, 4 cycle Emergency Motor-Generator Set Engine Make: Model: Fuel: HP Number cylinders Detroit (GM) 6-71 Diesel Approx. 200 6, 2 cycle Generator Make: Model: Type: Rating: Volts Amps: Cycles: RPM: December 1973 jtn Allis-Chalmers 6-GD-150 Brushless, synchroncu s 150 KW 480 225 60 1800 DO 124480 CONF IDFNT IAl, Page 42 V tn*f V. x' STEAM GENERATORS AND AUXILIARIES Steam Generators Make: No. of Units Type: Fue 1: Capacity: Air Preheater: Economizer: F. D, Fans: I. D. Fans: Combustion Control: Riley-Stoker 2 2-drum, balanced draft furnace Natural gas/Fuel oil 500,000#/Hr. at 1250 psi, 950 F. Tubular, 1-per unit Continuous tube type, 1-per unit 2 per unit 2 per unit Foxboro electro-pneumatic Make; No. of Units: Type: Fuel: Capacity: Air Preheater: Economizer: F, D, Fans: Combustion Control Make: No. of Units Type Fuel: Capacity: Air Preheater: Economizer: F. D. Fans: Combustion Control: Make: No. of Units: Type: Fuel: Capacity: Airheater: Economizer: F. D. Fans: Combustion Control Babcock & Wilcox 1 2 drum, forced draft Natural gas/ Fuel oil 750,000 ///hi. at 1250 psi, 550 F. Ljungstrom Continuous tube type 2 Foxboro electro-pneumatic Riley 1 1 drum, pressurized furnace Natural Gas 1,100,000 #/hr. at 1250 psi, Ljungstrom Finned Tube 2 Republic Electro-pneumatic 950 F. Riley 1 1 drum, Pressurized Furnace Natural Gas 1,600,000 #/hr. at 1250 psi, Ljungstrom Finned Tube 2 Foxboro 950 F, September 1976 DO 1P4481 r.ONFTDFNITlA! Page 43 STEAM GENERATORS AND AUXILIARIES (CONTD.) Boiler Feed Pumps Make: Capacity Motors: 4 Allis-Chalmers, 4 Pacific 3-6 X 6 BBDH-9 1-8 X 8 BBDH-7 2-6 X 6 LL-BFI 2-8 X 8 BFIS 3-1160 gpm pumping 275 F. water vs. 4000' TDH 1-1590 gpm pumping 275 F. water vs. 4000' TDH 2-1250 gpm pumping 275 F. water vs. 4000' TDH 2-1250 gpm pumping 275 F. water vs. 4000' TDH 3-1250 hp with 25% S. F. 1-1500 hp with 25% S. F. 2-1750 hp with 15% S. F. 2-2250 hp with 15% S. F. Spray Water Pump Pump Manufacturer: Size: Type: Stages: RPM: Capacity: Driver: Pacific Pumps 4" S BFIC (Barrel, centrifugal) 8 3570 720 gpm @ 3879 ft. head Manufacturer HP: RPM: Phase: Cycle: Volts: F. L. Amps: Allis-Chalmers 1000 3550 3 60 2300 215 POWER II FACILITIES 2--72"l'urbodyne GAs Turbine units with Deltak Regenerator and Heat Recovery steam generators supplying 235 psig and 30 psig process steam. Necessary auxiliary equipment, including Cooling Tower. Rev. 1/80/jml no j Page 44 r-ONFl Al. MOTOR POWER DISTRIBUTION' SUBSTATIONS STATISTICAL DATA Consists of ten subs with metal-clad, draw-out type switchgear. Substations 1 and 3 2 - 13.8 KV, 1200 Amp, 730 MVA Incoming ACB's 4 - 4.16 KV, 1200 Amp, 150 MVA feeder ACB's 1 - 13,800/2400 V, 7500/9375 KVA Transformer 1-60 cell, 130 volt station battery and charger 1 - Supervisory panel for remote indication and control Substations 2 and 4 2 - 13.8 KV, 1200 Amp, 750 MVA Incoming ACB's 3 - 4.16 KV, 1200 Amp, 150 MVA Feeder ACB's 1 - 4.16 KV, 2000 Amp, 150 MVA Feeder ACB's 1 - 13,800/2400 V, 7500/9375 KVA Transformer 1-60 cell, 130 volt station battery and charger 1 - Supervisory panel for remote indication and control. Substation 5 2 - 13.8 KV, 1200 Amp, 750 MVA Incoming ACB's 4 - 4.16 KV, 2000 Amp, 250 MVA Feeder ACB's 1 - 13,800/2400V, 10,000/12,500 KVA Transformer 1-60 cell, 130 volt station battery and charger 1 - Supervisory panel for remote indication and operation. Substations 6. 7, 8. 9. and 1,0 2 - 13.8 KV, 1200 Amp continuous, 1000 MVA interrupting capacity, incoming ACB's 4 - 4.16 KV, 2000 Amp continuous, 150 MVA interrupting capacity (3 2400V ACB's 1 - 13800/2400V, 11200/14000 KVA, 65 Rise Transformer 1-60 cell, 130 volt station battery and charger L - Supervisory panel for remote indication and control One (1) of the above subs, No. 9, has five (5) feeder ACB's Each substation has a preferred feeder off one bus at the power plant and a standby feeder off another power plant bus. Loss of the preferred feeder initiates automatic transfer to the standby feeder. September 1976 jm OO COl\lp 1^^480 TFNT rA; Page 4 5 WATER SUPPLY AND TREATING EQUIPMENT I.Supply The source of all water used in the Louisiana Division except for fire fighting is the Mississippi River. The water is pumped into a distri bution canal, from which the various plants take their supply for cool ing purposes. II. Clarification The Water Treating Plant takes raw river water from the distribution canal and treats it for various uses. The water is clarified in two (2) 7500 gpm units and two (2) 10,000 gpra units, by treatment with cationic polyelectrolyte and an anionic aid . This water is distri buted to the filtration plant and to the process plants. Ill. Filtration The portion of process water that flows to the filters is filtered through four rapid sand filters then chlorinated. This effluent is used as potable water. Water for the demineralizer plant is filtered through three (3) pressure filters. IV. Demineralizer Water The pressure filter effluent is dechlorinated prior to entering the demineralizer units. After demineralization the water flows to the Power Plant's two (2) 500,000 gallon condensate storage tanks. V. River Water Pumps Supply Make: Size; Capacity: Motor Size: 4-Peerless with Allis-Chambers Motors 1-Peerless with G.E. Motor 1-Fairbanks-Morse 3-48", 1-66", 1-72", and 1-84" 3-50,OOOgpm, 1-120,000 gpm 1,150,000 gpm, and 1-200,000 gpm 3-600 HP, 1-1250 HP, 1-1500 HP 1-2000 HP Return: Make: Size: Capacity: Motor Size: Rev. 1/80 Same as above 4-66", 1-72", and 1-84" 3-80,000 gpm, 1-120,000 gpm 1-150,000 gpm and 1,200,000 gpm 3-800 HP, 1-1250 HP, 1-1500 HP and 1-2000 HP. IDO 1 ?44B4 CONFIDENTIAL Page 46 WATER SUPPLY AND TREATING EQUIPMENT, (Con't) VI. Water Treating Equipment Clarifiers Make; No. of Units: Capacity: Storage; Infilco Accelator 4 2-7500 gpm each, and 1-10,000 gpm Cock. 500,000 gal, ground level tank, 250,000 elevated. Filters Make: Type: No, of Units: Capacity: Storage: Filter, Pressure Make: Type: No. of Units: Capacity Storage Infilco Rapid sand 4 500 gpm each Underground, 100,000 gal, capacity Best Manufacturing Pressure 3 920 GPM Each None Cations Make: No, of Units: Capacity: Resin volume: Resin: Graver-Best Manufacturing-Mosites ;3-Graver, 1-Best, 1-Mosites 6B0 GPM Avg. 625 cu. ft, each Dowex 50W, cycle Vacuum Degasifier No. of Units Make: Capacity: 2 Graver No. 1-1500 gpm, No. 2-2500 gpw Weakly Basic Anions Make: No. of Units: Capacity: Resin Volume: Resin: Graver -Best Manufacturing-Mositef 2-Graver, 1-Best, 1-Kosites 540 GPM Avg. Each 625 Cu. Ft. Each Dowex 4, OH cycle, Units 1 end 2 Dowex 44, OH cycle, Unit No. 3 end 4 Rev. 1/80 jml Page 47 DO 1P4485 CONFTDFNTTAl WATER SUPPLY and TREATING EQUIPMENT, (Cont'd) Strongly Basic Anions Make: No. of Units: Capacity: Resin Volume: Resin: Graver, Best Manufacturing, Mosites 2-Graver, 1-Best, l-Mosites 540 GPM, Avg. Each 475 Cu. Ft. Units No. 1&2, 600 Cu. Ft. Units No. 3&4 Dowex 21-K, OH cycle VII. Sewerage System Equipment Collection System No. of Lift Stations: Type: 7 Wet Pit Treating System Capacity: Type: 90 GPM Primary digestor, biological filter and final clarifier, with sludge recirculation. ~Rev. 1/80 Page 48 1^4486 CONFTDFNTrAl ti. *!'