Document 3qRXbEXOL33BnB2vo9EZ8oYJ
. > I
t m-- t pmh--i
S. C. Enders, Jr.
Fra*--Nam * OaaaniMM
A. C. Barbaglia
Plant Manager Industrial Hygiene
Inter Company Corroapontfonca
Mmmw >.
P
Apri*l 23 .1--9--8--4-
Stamping & Div.Operations
OtotMaa
Industrial Relations
Trenton Chemical
Chrysler Center
PiU Crf
CIMS Nawaar
453-02
CIMS Nvmtnr
417-05
An Industrial Hygiene investigation of the Trenton Chemical Plant was conducted on February 20, 1984 for employee exposure to asbestos in the Friction Products
Bldg, and formaldehyde in the plastic piston cap operation.
Sample results indicated four operations with employee exposure levels in excess of the 0.5 fiber/cc permissible exposure limit for asbestos.
It is recommended that employees performing these jobs wear respiratory protection (NPSP 220E). In addition, the plant should explore engineering solutions (i.e. increased ventilation, enclosures) to control employee asbestos expo
sure. Employees should also be instructed on the hazards associated with asbestos and good work practices to minimize exposure to asbestos dust.-
All other samples results indicated employee exposure levels for asbestos to be within allowable exposure limits.
As required by the asbestos standard employees exposed to concentrations in excess of 0.1 fibers/cc are required to have an annual medical examination which is to include a chest x-ray and a pulmonary function test. Finally, those employees sampled shall be notified of their sample results in writing within five days of receipt of this report.
Sample results determining employee exposure levels to formaldehyde in the plastic piston cap operation indicated all concentrations below the 1 ppm permissible exposure limit.
If you have questions regarding this report, contact the writer.
hm
Attachments cc: F. A. Burnett
D. S. Buza
G. Chomakos D. R. Dolenga
R. Gryniewicz R. J. Horoky N< UcCallum
v*. i
A. C. Barbaglta Industrial Hygienist
R. D. McIntosh, M.D. D. E. Pentecost A. H. Sokolowski, M.D. G. A. Sattelmeier R. L. Stewart
Data Sheet Trenton Chemical Plant
February 20, 1984
Asbestos
Permissible Exposure Limit
Concentration (fibers/cc)
Friction Products Bldg. - #14 Press and #3 Bipel .operator - (wearing respirator)
Repeat on #'s 27 and 28 Press and #7 Bipel
0.4 0.8
Friction Products Bldg.- #13 Press and #3 Bipel Operator -(wearing respirator)
Repeat on #'s 21 and 22 Press and #5 Bipel
0.6 0.9
Friction Products Bldg. OEM Grinder
north
Repeat
Time-weighted average
0.4
0.3 0.3
Friction Products Bldg. - Inspector Rivit Machine and Plastic Piston Cap
Repeat
Time-weighted average
Friction Products Bldg. - #3 and 4 Saw Operator and Press Unloader
<0.1 0.2 0.1
0.6
Friction Products Bldg. Saw Conveyor Unloader
#3 and 4
0.2
Friction Products Bldg. Grinder Operator
Gardner
0.4
All samples were collected on Cellulose Ester Filters using MSA Model G Pumps and analyzed by phase contrast microscopy.
Data Sheet Trenton Chemical Plant
February 20, 1984
Formaldehyde
Permissible Exposure Limit
Plastic Piston Cap - #5 Machine Operator, Relief on #4
Concentration (ppm) 0.02
Plastic Piston Cap - #3 Machine Operator, Relief on #1 and 2
0.03
Plastic Piston Cap - #4 Machine Operator, Relief on #5
0.03
Plastic Piston Cap - #1 and 2 Machine Operator, Relief on *3
0.02
All samples were collected on 3M Passive Diffusion Badges and analyzed by Colori metric methods.