Document 3nz2r6Rd1dvq7jZdEw76py9O

Boilers, Healing Fitzgibbons Boiler Co., Inc. ESTABUSEBD 1886 General Offices: 570 Seventh Avenue, New York City PRODUCTS Fitzgibbons Copper Steel Boilers for Steam or Hot Water Heating. Table 1. Fitzgibbons Copper Steel Smokeless Boilers for Steam or Hot Water Heating. Table 1-B. Fitzgibbons (Intermediate Sized) Steel Boilers for Steam or Hot Water Heating. Table 2. Fitzgibbons All Riveted Steel Boilers for Heating and for Power. Table 3 and Table 4. (Not shown). Fitzgibbons Steel Boilers: Embodying the original Fitzgibbons cylindrical furnace, entirely free from brickwork, the high combustion chamber, the gas-deflecting arch, the secondary air preheater, and the effective single pass of many relatively small tubes, Fitzgibbons Steel Boilers have, for more than forty years, proved their twin qualities, notabte fuel economy and lifetime service, substantially without main tenance expense. Construction: The cylindrical design of the Fitzgibbons Steel Boiler affords the strongest possible construction with minimum of internal bracing; and the complete water-jacketing of the vertical furnace insures exceptionally long life as well as high efficiency. The entire interior of the Boiler is visible and accessible for inspection or cleaning. Combustion: Complete combustion of the fuel and its consumable gases is attained with a minimum of excess air. The circular Fitzgibbons grate is free from dead corners and maintains a hot, uniform fire. The wholly visible grate encourages and assists careful firing. The high cylindrical combustion chamber is now recog nized as essential to complete combustion. The Fitzgibbons Steel Healing Boiler. Table 8 530 Fitzgibbons Copper-Steel Heating Boiler for small-sized installations, homes, churches, garages, etc. rear gas-deflecting arch diverts the gases forward into intimate mixture with the preheated secondary air which enters through a port above the firing door. As the air-gas mixture whirls upward combustion is completed before the gases enter the tubes, resulting in very high furnace temperatures,--often close to 3000 deg. fahr. Smokeless com bustion of semi-bituminous coal in dicates the thoroness of this combustion. Conduction and Circulation: The absorption of the heat so effectively generated in the Fitzgibbons furnace is accomplished by the unique design of this time-proved Boiler. The water line is carried in the vertical shell directly above the combustion chamber, the hoHzontal tube Cylinder being com pletely filled with water. Therefore the circulation of the water is extremely rapid as the boiler steams and the bub bles move along fixed paths toward the steam chamber. This rapid circulation insures heat absorption as effective as the heat generation accomplished in the furnace as is evidenced by (1) the quick steaming capacity, (2) less than 1 per cent moisture in steam regardless of overload carried, and (3) unusually low flue-gas temperatures. Detailed Information will be mailed promptly upon request. Fitzgibbons Boiler Co., Inc. Boilers, Heating TABLES 1 AND 1-B COMBINED--FITZGIBBONS STEEL HEATING & SMOKELESS HEATING BOILERS Double-Electric-Welded Furnaces Sizes 300 to 3200 sq. ft. Steam Rating--Built for 15 lb. w.s.p.--A.S.M.E. Code No. of Boiler................. J-6 J-8 k-8 J-10 J-12 H-16 H-20 H-24 H-28 H-32 k-36| H-44J H-50 k-58 H-64 No. of Smokeless Boiler.. None None B-8 B-10 B-12 B-16 B-20 B-24 B-28 B-32 B-36 B-44 B-50 B-58 B-64 Steam Rating......... sq. ft. 300 Hot Water Rating.. .sq. ft. 500 400 700 400 700 500 600 800 1000 1200 1400 1600 1800 2200 2500 2900 3200 800 1000 1300 1600 1900 2200 2600 2900 3500 4000 4600 5100 Heating Surface.... a. ft. 30 Comp. Crate Area.-. .sq. ft. 2.5 33 2.5 35 3.36 43 3.36 51 5.36 67 4.35 78 4.35 95 5.84 108 5.84 173 7.10 150 7.10 192 8.50 233 249 295 8.50 10.00 10.00 Diam. Vertical Shell .. .in. 23 Length Bare Boiler. ft. in. 3-3 23 3-3 26 3-9 26 4-1 26 4-5 29 4-9 29 5-3 33 33 5-fl 6-2 37 37 6-9 7-9 40 40 7-7 8-7 43 43 8-4 9-4 Diam. Horizontal Shell.. in. 18 Water Line............. ft. in. 3-5 Diameter Base....... 261/. Fire Door Center... .. .in. 25V? 18 3-5 261/, 25'/ 18 3-7 30 27 18 18 3-7 3-7 30 30 27 27 21 21 23 23 27 27 31 31 33 33 4-0 4-0 4-4 4-4 4-7 4-7 4-11 4-11 5-2 5-2 T 15* 15*33* 37'/j 37/j V2 31 31 42% 42% 31 31 '1 $ m $ & S4Overall Height........ .ft. in. 4-2 4-2 4-3 4-3 4-3 4-8 4-8 5-0 5-0 5-5 5-5 5-9 5-9 6-1 6-1 Width of Uptake... Length of Uptake.. Tube Space............ Grate Diameter.... Stack Diameter----- Stack Height.......... Shiooing Weight. . . .. .in. .. .in. ...ft. lb* I2'A 18 19 8 35 900 18 19 8 40 920 12V? 5V4 12V, VA 12'/, 15^ l7Vi &A 10 10 25 25 18 18 22 24 30 27 32 D 43 35 47 40 52 22 22 22 25 75 29 29 32 32 35 35 38 38 8 8 8 10 10 12 12 14 14 16 16 18 18 40 45 45 40 45 45 45 50 50 50 60 60 60 1150 1175 1225 1525 1625 2000 2100 2400 2460 3000 3200 3550 3800 TABLE 2--FITZGIBBONS STEEL HEATING BOILERS Double-Electrie-Welded Furnaces Sizes 3800 to 19000 sq. ft. Steam Rating--Built for 15 lb. w.s.p.--A.S.M.E. Code No. of Boiler................... B-76 B-86 H-98 B-108 8-120 B-132 B-144 B-160 B-170jB-200 B-220 6-250^-270^-310 B-3301H-360 B-380 Steam Rating...........sq. ft. 3800 Hot Water Rating.. .sq. ft. 6000 4300 6900 4900 5400 6000 6600 7200 8000 8500 10000 11000 1250013500;15500 16500 18000 19000 7900 8700 9600 II000 12000 13500 I4500jt6000 17500 20000,2150025000 26500 29000 30500 Heating Surface........sq. ft. 354 393 397 428 497 582 665 674 772 826 920 1048 1109 1308 1372 1511 1571 "Comp. Grate Area... sq. ft. 12.8 12.8 15.4 15.4 18.8 18.8 18.8 21.0 21.0 24.2 24.2 29.4 29.4 32.0 32.0 36.0 36.0 Diam. Vert. Shell. .. .ft. in. 4-0 4-0 4-4 4-4 4-9 4-9 4-9 5-0 5-0 5-4 5-4 5-10 5-10 6-2 6-2 6-6 6 6 Length Bare Boiler.. .ft. in. 9-1 10-1 9-7 10-7 9-9 10-9 11-9 10-10 11-10 11-10 12-10 12-2 12-8 14-0 14-6 14-3 15-2 Diam. Horiz. Shell... ft. in. 3-4 3-4 3-6 3-6 4-0 4-0 4-0 4-3 4-3 4-6 4-6 5-0 5-0 5-2 5-2 5-6 5-6 Water Line................ ft. in. 6-0 6-0 6-0 6-0 6-7 6-7 6-7 6-11 6-11 8-3 8-3 8-9 8-9 8-11 8-11 9-6 9-6 Overall Height.......... ft. in. 7-1 7-1 7-2 7-2 7-10 7-10 7-10 8-2 8-2 9-5 9-5 10-0 10-0 10-2 10-2 11-0 11-0 Smoke Uptake.......in. x in. I3'/2x26 13'/2x26 14x27 14x27 14x37 14x37 14x37 14x44 14x44 15x49 15x49 16x58 16x58 17x58 17x58 18x63 18x63 Tube Space................ft. in. 3-10 Grate Diameter.............. in. 43 4-10 43 3-9 4-9 3-9 4-9 5-9 4-9 5-9 6-7 7-7 6-6 7-0 7-10 8-4 7-9 8-8 47 47 52 52 52 55 55 59 59 65 65 68 68 72 72 Stack Diameter:............ in. 20 22 22 22 24 24 24 26 26 28. 30 30 30 32 32 34 34 Stack Height...................ft. 60 65 65 70 70 70 70 60 80 80 80 65 85 100 100 125 125 Shipping weight............lbs. 5250 6100 6650 7400 9000 9500 lOOOOj 10500 11000 13000 13800 15200 16000 18400 190001J950020500 TABLE 3--FITZGIBBONS STEEL HEATING AND POWER BOILERS All-Riveted Construction--A.S.M.E. Code Sizes 4200 to 36000 sq. ft. Steam Rating--Heating Boilers Built for 15 lb. w.s.p. Power Boilers, for Kitchen, Laundry, Drying, Process and similar High-Pressure Loads, Built for 100 lb. w.s.p. No. of Boiler... rr.'..................... 23 24 25 26 27 29 30 31 32 33 34 35 36 37 Horse Power................................. 40 50 60 70 80 too 125 150 175 200 225 250 300 350 Steam Rating........................ Hot Water Rating............... 4200 5400 6400 7500 8500 11000 13500 16500 19000 22000 25000 28000 32000 36000 _==_6/U0 8700 10500 12000 14500 ------ ;_=__ 17500 21500 '' 26500 ___ I 30500 35000 40000 45000 -- --51000 --560--00. Heating Surface.................... 380 456 547 631 721 917 1147 1350 1571 1823 7012 2271 2760 3220 __Comparative Grate Area.... . .sq. ft. 13.2 15.3 17.4 18.8 21.0 24.2 ___ - . - -- - 29.4 . 33.0 36.0 38.1 -- --40.2 --44.5 --50.2 _5_7_._5_ Diameter Vertical Shell........ . .ft. in. 4-1 4-5 4-8 4-10 5-1 5-5 5-11 6-3 6-7 6-9 6-11 7-3 7-8 8-4 Height Overall...................... 8-6 8-9 9-2 9-5 9-9 10-1 10-8 11-0 11-11 12-1 17-2 12-6 13-0 13-6 Length Bare Boiler............... 9-4 10-6 10-9 12-2 12-3 13-7 13-11 15-1 15-4 16-2 17-5 18-2 19-2 19-6 Diameter Horizontal Shell... . .ft. in. 3-5 3-8 3-11 4-1 4-4 4-7 5-1 5-3 5-7 5-9 5-9 6-1 6-6 7-1 Smoke Uptake.................,v. .in. x in. 12x24 I2xil 13x36 13x42 13x48 14,/2x49 15Ax58 17x58 18x6214 19x65 19x65 20x66 24x73 24x60 Space to Draw lubes........... . .ft. in. 4-8 5-7 5-6 6-10 6-10 7-9 7-8 8-6 8-4 8-10 10-0 10-5 11-0 11-0 Water IJne........................... Grate Diameter.................... 7-1 7-4 7-8 7-11 8-2 8-5 in 43 47 50 52 55 59 8-11 9-1 9-10 10-1 10-1 10-5 11-4 11-10 65 68 72 74 76 80 85 91 Stack Diameter.................... ....... in. 22 22 24 24 26 Stack Height........................ ........ft. 65 70 70 70 80 28 80 30 32 34 34 38 40 48 48 90 100 125 140 140 140 165 190 Shipping Weight................... ...lbs. 7500 9500 10000 11500 12000 15200 18000 20000 23000 26000 29000 32000 37000 44000 *It has been established that the Circular Grate in the Fitzgibbons Cylindrical Furnace is more effective thana rectangular grate the size'of the circumscribed square. Hence, for comparative purposes, the Comparative Grate Area shown in the Tables is the area of the square circumscribed upon a circle the size of the Fitzgibbons Grate. 531