Document 3n0yY2Rny9g9rEqOaQrVnMqJ

ASME Boiler and Pressure Vessel Code SECTION IV INTERPRETATIONS Volume 41 ^' ' V- V' " 1 r. . .i The Jnterpretatiofijglo, the Code will be issued twice a year up to the publication of the 1998 Editiop of the Code: each July (designated 7/95, 7/96, and 7/97) and with each Addenda (designated A95,; A96, and A97). The Interpretations for each individual Section are published separately and are part of the update service to that Section; Interpretations of Section III, Divisions 1 and 2, are parti of thCxipdate Service to Section III, Subsection NCA. Interpretations are not part of the Code or the Addenda. 't ' *' *.J. Interpretations Volumes 30 through 35 were included with the update service to the 1992 Edition of the Code; Volume 36 is the first Interpretations volume to be included with the update service to die 1995 Edition? > ;. Section 1 ll-A 11-6 i ll-C ll-D ' 1 ttl-NCA 111-3 .. IV vVI. ..Vvu '' ' * Vlll-1 '"'^VJIl-2 r- -A,XI Vof. 36 7/9S 7/95 , 7/95 Vol. 37 A95 Vol. 38 7/96 7/96 t 7/95 7/95 /9S i 7/95 '7/95 1 7/95 7/^5 A95 A95 A95 .... ' A95 A95 A95 v. m a9s 1 7/96 7/96 7/96 ,,. 7/96 - 7/96 -. '7/96 W6 7/96 Vol. 39 A96 A96 A96 A96 A96` A96 A96 A96 Vol. 40 7/97 7/97 7/97 7/97 7/97 7/97 . 7/97 7/97 7/97 Vol. 41 A97 A97 A97 A97 A97 A97 A97 A97 A97 A97 RS-002797 1/17/02 NUECE8 INTERPRETATIONS NO. 41 -- SECTION IV Replies to Technical Inquiries January 1, 1997 through June 30, 1997 FOREWORD General Information This publication includes all written interpretations issued between the indicated dates by the ASME Staff on behalf of the ASME Boiler and Pressure Vessel Committee in response to inquiries concerning interpretations of the ASME Boiler and Pressure Vessel Code. A contents is also included which lists subjects specific to the interpretations covered in the individual volume. These interpretations are not a part of the Addenda or the Code. The interpretations are taken verbatim from the original letters, except for a few typographical and editorial corrections made for the purpose of improved clarity. In some instances, a review of the interpretation revealed a need for corrections of a technical nature. In these cases, a revised interpretation is presented bearing the original Interpretation Number with the suffix R and the original file number with an asterisk. Following these revised interpretations, new interpretations and revisions to them issued during the indicated dates are assigned Interpretation Numbers in chronological order. Interpretations applying to more than one Code Section appear with the interpretations for each affected Section. ASME procedures provide for reconsideration of these interpretations when or if additional information is available which the inquirer believes might affect the interpretation. Further, persons aggrieved by an interpretation may appeal to the cognizant ASME committee or subcommittee. As stated in the Statement of Policy in the Code documents, ASME does not "approve," "certify," "rate," or "endorse" any item, construction, proprietary device, or activity. An interpretation applies either to the Edition and Addenda in effect on the date of issuance of the interpretation or the Edition and Addenda stated in the interpretation. Subsequent revisions to the Code may supersede the interpretation. For detailed instructions on preparation of technical inquiries to the ASME Boiler and Pressure Vessel Committee, refer to Appendix I. 197 RS-002798 1/17/02 NUECES SECTION IV Subject_________ Interpretation HG-530.2, Marking Requirements for Cast Iron Boilers .................................... IV-95-24 HG-330.2(d), Nameplates ............................................................................................ IV-95-25 HLW-101, Service Restriction and Exception ......................................................... IV-95-26 HLW-502.2(a), Test Gages.......................................................................................... IV-95-27 File No. BC97-052 BC95-236 BC96-502 BC96-187 199 R8-002799 1/17/02 NUECES Section IV -- Interpretations No. 41 Interpretation: IV-95-24 IV-95-24, IV-95-25 Subject: HG-530.2, Marking Requirements for Cast Iron Boilers Date Issued: March 19, 1997 File: BC97-052 Question (1): In HG-530.2(a)(5), is it permissible to omit the shop-assembler's name? Reply (1): Yes. Question (2): In HG-530.2(a)(2) and Fig. HG-530.4, is it permissible to also show the MAWP for Canada? Reply (2): Yes. Interpretation: IV-95-25 Subject: HG-530.2(d), Nameplates Date Issued: Juhe 9, 1997 File: BC95-236 Question (1): Is it the responsibility of the cast iron boiler manufacturer to permanently attach the nameplate to the casing when the boiler is assembled by the manufacturer? Reply (1): Yes. Question (2): Is it the responsibility of the cast iron boiler manufacturer to permanently attach the nameplate to the casing when using an adhesive nameplate that meets the requirements of Appendix 3 and when the boiler is assembled by the manufacturer? Reply (2): Yes. 201 R8-002800 1/17/02 NUECES 1998 Edition Available July 1, 1998 ASME Boiler & Pressure Vessel Code AN INTERNATIONAL CODE RS-002802 1/17/02 NUECES 1998 ASME Boiler & Pressure Vessel Code An International Code 1 Power Boilers ISBN 0-7918-2494-2 Order No. QX0010 ....................... . . $210.00 II Materials Part A -- Ferrous Material Specifications ISBN 0-7918-2495-0 Order No. QX002A......................... . . $385.00 Part B -- Nonferrous Material Specifications ISBN 0-7918-2496-9 Order No. QX002B ......................... . . $350.00 Part C -- Specifications for Welding Rods, Electrodes, and Filler Metals ISBN 0-7918-2497-7 Order No. QX002C ......................... . . $350.00 Part D -- Properties ISBN 0-7918-2498-5 Order No. QX002D............... -r. . . . . $315.00 Appendices ISBN 0-7918-2507-8 Order No. QX003A..............................$250.00 Division 2 Code for Concrete Reactor Vessels and Containments ISBN 0-7918-2508-6 Order No. QX0032 ..............................$295.00 Division 3 Containment Systems and Transport Packagings for Spent Nuclear Fuel and High Level Radioactive Waste ISBN 0-7918-2509-4 Order No. QX0033 ..............................$275.00 IV Heating Boilers ISBN 879182510-8 Order No. QX0040 ........................... . $195.00 X Fiber-Reinforced Plastic Pressure Vessels ISBN 0-7918-2518-3 Order No. QX0100 ............................ $185.00 XI Rules for Inservice Inspection of Nuclear Power Plant Components ISBN 0-7918-2519-1 Order No. QX0011 ............................ $370.00 Code Cases: Boilers and Pressure Vessels ISBN 0-7918-2520-5 Order No. QX0120 ............................$275.00 Code Cases: Nuclear Components ISBN 0-7918-2521-3 Order No. QX012N............................ $315.00 Ill Rules for Construction of Nuclear Power Plant Components Subsection NCA General Requirements for Division 1 and Division 2 ISBN 0-79182499-3 Order No. QX003R ......................... . $240.00 Division 1 Subsection NB Class 1 Components ISBN 0-79182500-0 Order No. QX003B ......................... . $240.00 Subsection NC Class 2 Components ISBN 0-79182501-9 Order No. QX003C ......................... . $240.00 Subsection ND Class 3 Components ISBN 0-7918-2502-7 Order No. QX003D......................... . $240.00 Subsection NE Class MC Components ISBN 879182503-5 Order No. QX003E ......................... . $240.00 Subsection NF Supports ISBN 87918-2504-3 Order No. QX003F ......................... . $185.00 Subsection NC Core Support Structures ISBN 8791825081 Order No. QX003C......................... . $185.00 Subsection NH Class 1 Components in Elevated Temperature Service ISBN 87918-2506-X Order No. QX003H......................... . $240.00 V Nondestructive Examination ISBN 879182511-6 Order No. QX0050 ........................... . $215.00 VI Recommended Rules for the Care and Operation of Heating Boilers ISBN 879182512-4 Order No. QX0060 ........................... $125.00 VII Recommended Guidelines for the Care of Power Boilers ISBN 8791825182 Order No. QX0070 ........................... $145.00 VIII Pressure Vessels Division 1 ISBN 87918-2514-0 Order No. QX0081 ........................... $385.00 Division 2 Alternative Rules ISBN 8791825189 Order No. QX0082 ........................... $385.00 Division 3 Alternative Rules for Construction of High Pressure Vessels ISBN 8791825187 Order No. QX0083 ........................... $295.00 IX Welding and Brazing Qualifications ISBN 0-7918-2517-5 Order No. QX0090 ........................... $215.00 Binder The Code is available in loose-leaf format only. A customized binder is available for your con venience: reinforced hinges, 5-prong mecha nism, 2'/2" capacity. Order No. QX0140 ...............................$20.00 Special Price for Complete Code Order No. QX0230 ......................... $6,550.00 Complete Code Plus 30 Binders Order No. QX0330 ......................... $7,150.00 Update Service Includes: Addenda issued twice: July 1, 1999, 2000 Supplements issued 4 times per year for each Code Case Book Interpretations issued twice per year: with Addenda and in December 1998, 1999, 2000. Note: Interpretations will not be available separately and are issued as part of the update service to the individual sections of the Code. Interpretations to Section III. Divisions I and 2 are issued as part ofupdate to Subsection NCA. TO ORDER: Call toll free: 800-843-2763 Fax: 201-882-1717 Write: ASME 22 Law Drive Box 2300 Fairfield, NJ 07007-2300 Email: infocentral@asme.org Prices subject to change without notice. Shipping/ handling charges added to every order. RS-002803 1/17/02 NUECES ASME Boiler and Pressure Vessel Code SECTION IV INTERPRETATIONS Volume 40 The Interpretations to the Code will be issued twice a year up to the publication of the 1998 Edition of the Code: each July (designated 7/95, 7/96, and 7/97) and with each Addenda (designated A95, A96, and A97). The Interpretations for each individual Section are published separately and are part of the update service to that Section; Interpretations of Section III, Divisions 1 and 2, are part of the update service to Section III, Subsection NCA. Interpretations are not part of the Code or the Addenda. Interpretations Volumes 30 through 35 were included with the update service to the 1992 Edition of the Code; Volume 36 is the first Interpretations volume to be included with the update service to the 1995 Edition. Section 1 ll-A ll-B ll-C ll-D lll-NCA IV V VI VII VIII-1 VIII-2 IX X XI Vol. 36 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 Vol. 37 A95 A95 A95 A95 A95 A95 A95 A95 Vol. 38 7/96 7/96 7/96 7/96 7/96 7/96 7/96 7/96 7/96 7/96 Vol. 39 A96 A96 A96 A96 A96 A96 A96 A96 Vol. 40 7/97 7/97 7/97 7/97 7/97 7/97 7/97 7/97 7/97 Copyright O 1997 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS All Rights Reserved P040I7 RS4)02804 1/17/02 NUECES INTERPRETATIONS NO. 40 -- SECTION IV Replies to Technical Inquiries July 1, 1996 through December 31, 1996 FOREWORD General Information This publication includes all written interpretations issued between the indicated dates by the ASME Staff on behalf of the ASME Boiler and Pressure Vessel Committee in response to inquiries concerning interpretations of the ASME Boiler and Pressure Vessel Code. A contents is also included which lists subjects specific to the interpretations covered in the individual volume. These interpretations are not a part of the Addenda or the Code. The interpretations are taken verbatim from the original letters, except for a few typographical and editorial corrections made for the purpose of improved clarity. In some instances, a review of the interpretation revealed a need for corrections of a technical nature. In these cases, a revised interpretation is presented bearing the original Interpretation Number with the suffix R and the original file number with an asterisk. Following these revised interpretations, new interpretations and revisions to them issued during the indicated dates are assigned Interpretation Numbers in chronological order. Interpretations applying to more than one Code Section appear with the interpretations for each affected Section. ASME procedures provide for reconsideration of these interpretations when or if additional information is available which the inquirer believes might affect the interpretation. Further, persons aggrieved by an interpretation may appeal to the cognizant ASME committee or subcommittee. As stated in the Statement of Policy in the Code documents, ASME does not "approve," "certify," "rate," or "endorse" any item, construction, proprietary device, or activity. An interpretation applies either to the Edition and Addenda in effect on the date of issuance of the interpretation or the Edition and Addenda stated in the interpretation. Subsequent revisions to the Code may supersede the interpretation. For detailed instructions on preparation of technical inquiries to the ASME Boiler and Pressure Vessel Committee, refer to Appendix I. RS-002806 1/17/02 NUECES SECTION IV Subject HG-602, Internal Siphon........................................... HG-614 and Fig. HG-703.2 -- Low-Water Cutoff HLW-200 ................................................................... Materials -- Table HF-300.1................................... Interpretation IV-95-21 IV-95-23 IV-95-20 IV-95-22 File No. BC95-479 BC96-361 BC94-627 BC96-188 R8-002806 1/17/02 NUECES Section IV -- Interpretations No. 40 IV-95-20, IV-95-21, IV-95-22 Interpretation: IV-95-20 Subject: HLW-200 Date Issued: July 1, 1996 File: BC94-627 Question: May a water heater or storage tank be built to Part HLW and Code stamped if the entire interior of the vessel is covered with a minimum of 0.005 in. nickel applied by the thermal spray process, then the entire interior lined with polyamine epoxy? Reply: Yes, provided all the conditions of the use of amine or polyamine epoxy linings as described in HLW-200(f) are met. Interpretation: IV-95-21 Subject: HG-602, Internal Siphon Date Issued: October 22, 1996 File: BC95-479 Question (1): Does the use of a gage incorporating an internal siphon meet the requirement of HG-602? Reply (1): Yes. Question (2): Does the internal siphon have to meet the size requirements for external siphon connections as specified in HG-602? Reply (2): No. Interpretation: IV-95-22 Subject: Materials -- Table HF-300.1 Date Issued: December 31, 1996 File: BC96-188 Question: In the 1995 Edition of Section II, SA-515 Grade 55 is no longer included. However, in Section IV, Table HF-300.1 still lists SA-515 Grade 55 and gives an allowable stress value. Is it still permitted to use SA-515 Grade 55 boiler plate in Section IV construction? Reply: Yes. Please refer to Appendix A of Section II, Part A. RS-002807 1/17/02 NUECES 195 IV-95-23 Interpretation: IV-95-23 Section IV -- Interpretations No. 40 Subject: HG-614 andFig. HG-703.2 -- Low-Water Cutoff Date Issued: December 30, 1996 File: BC96-361 Question: Does HG-614 or Fig. HG-703.2 require a low water cutoff of a specific type in the locations shown in Fig. HG-703.2? Reply: No. 196 R8-002808 1/17102 NUECES ASME Boiler and Pressure Vessel Code SECTION IV INTERPRETATIONS Volume 38 The Interpretations to the Code will be issued twice a year up to the publication of the 1998 Edition of the Code: each July (designated 7/95, 7/96, and 7/97) and with each Addenda (designated A95, A96, and A97). The Interpretations for each individual Section are published separately and are part of the update service to that Section; Interpretations of Section III, Divisions 1 and 2, are part of the update service to Section III, Subsection NCA. Interpretations are not part of the Code or the Addenda. Interpretations Volumes 30 through 35 were included with the update service to the 1992 Edition of the Code; Volume 36 is the first Interpretations volume to be included with the update service to the 1995 Edition. Section 1 ll-A ll-B ll-C ll-D lll-NCA IV V VI VII VIII-1 VIII-2 IX X XI Vol. 36 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 Vol. 37 A95 A95 A95 A95 A95 A95 A95 A95 Vol. 38 7/96 7/96 7/96 7/96 7/96 7/96 7/96 7/96 7/96 7/96 Vol. 39 Vol. 40 Vol. 41 Copyright 1996 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS All Rights Reserved RS-002809 1/17/02 NUECE8 P040I6 INTERPRETATIONS NO. 38 -- SECTION IV Replies to Technical Inquiries July 1, 1995, through December 31, 1995 FOREWORD General Information This publication includes all written interpretations issued between the indicated dates by the ASME Staff on behalf of the ASME Boiler and Pressure Vessel Committee in response to inquiries concerning interpretations of the ASME Boiler and Pressure Vessel Code. A contents is also included which lists subjects specific to the interpretations covered in the individual volume. These interpretations are not a part of the Addenda or the Code. The interpretations are taken verbatim from the original letters, except for a few typographical and editorial corrections made for the purpose of improved clarity. In some instances, a review of the interpretation revealed a need for corrections of a technical nature. In these cases, a revised interpretation is presented bearing the original Interpretation Number with the suffix R and the original file number with an asterisk. Following these revised interpretations, new interpretations and revisions to them issued during the indicated dates are assigned Interpretation Numbers in chronological order. Interpretations applying to more than one Code Section appear with the interpretations for each affected Section. ASME procedures provide for reconsideration of these interpretations when or if additional information is available which the inquirer believes might affect the interpretation. Further, persons aggrieved by an interpretation may appeal to the cognizant ASME committee or subcommittee. As stated in the Statement of Policy in the Code documents, ASME does not "approve," "certify," "rate," or "endorse" any item, construction, proprietary device, or activity. An interpretation applies either to the Edition and Addenda in effect on the date of issuance of the interpretation or the Edition and Addenda stated in the interpretation. Subsequent revisions to the Code may supersede the interpretation. For detailed instructions on preparation of technical inquiries to the ASME Boiler and Pressure Vessel Committee, refer to Appendix I. RS-002810 1/17/02 NUECES SECTION IV Subject_________ HG-312 and HF-204.2(c), Requirements for the Minimum Wall Thickness of SA-249, 316L Stainless Steel Fire Tubes Attached by Welding to Tubesheets. HG-360.2(d), Requirements for Tubesheets and Tube Attachments........................................................................................... HG-614 and HG-615, Requirements for Low-Water Fuel Cuttoff...................... Interpretation IV-95-15 IV-95-14 File No. BC95-178 BC95-224 RS-0028'*1 181 Section IV -- Interpretations No. 38 Interpretation: IV-95-14 IV-95-14, IV-95-15 Subject: HG-614 and HG-615; Requirements for Low-Water Fuel Cutoff Date Issued: July 31, 1995 File: BC95-224 Question: Does Section IV require a low-water cutoff on an assembled system, modular hot water heating boiler, if the system has a heat input greater than 400,000 Btu/hr but each separate module is less than 400,000 Btu/hr? Reply: Yes. Interpretation: IV-95-15 Subject: HG-312 and HF-204.2(c); Requirements for the Minimum Wall Thickness of SA-249, 316L Stainless Steel Fire Tubes Attached by Welding to Tubesheets. HG-360.2(d); Requirements for Tubesheets and Tube Attachments Date Issued: File: October 31, 1995 BC95-178 Question (1): Does HG-312.2 require the addition of 0.04 in., to the required thickness determined by the procedures of HG-312.2 as an allowance for rolling and structural stability for tubes that are welded? Reply (1): No. Question (2): Are either Fig. HF-312.1 or HG-312.2 applicable to SA-249 TP316L stainless steel tubing? Reply (2): No. Section IV does not contain external pressure charts for stainless steel materials. However, the external pressure charts of Section n, Part D, may be used to determine A and B factors for stainless steel materials permitted by Section IV, provided a temperature of 500F is used in selecting the B factor and the equation provided in HG-312.3 Step 6 is used to calculate the allowable pressure. Question (3): Is the minimum required tube wall thickness for stainless tubes subjected to external pressure the greater of the thickness required by HG-312.3, determined as described in Question (1) and Question (2)? Reply (3): Yes. Question (4): HG-360.2(d) states that holes may be punched full sized and tubes may be attached by fillet welding from one side only without expanding if the tubesheet thickness does not exceed 5/i6 in. Is the 5/16 in., thickness referred to in HG-360.2(d) a nominal thickness? Reply (4): Yes. RS-002812 1/17/02 NUECES 183 RS402813 1/17/02 NUECES ASME Boiler and Pressure Vessel Code SECTION IV INTERPRETATIONS Volume 37 The Interpretations to the Code will be issued twice a year up to the publication of the 1998 Edition of the Code: each July (designated 7/95, 7/96, and 7/97) and with each Addenda (designated A95, A96, and A97). The Interpretations for each individual Section are published separately and are part of the update service to that Section; Interpretations of Section III, Divisions 1 and 2, are part of the update service to Section III, Subsection NCA. Interpretations are not part of the Code or the Addenda. Interpretations Volumes 30 through 35 were included with the update service to the 1992 Edition of the Code; Volume 36 is the first Interpretations volume to be included with the update service to the 1995 Edition. Section 1 ll-A ll-B ll-C ll-D lll-NCA IV V VI VII VIII-1 VIII-2 IX X XI Vol. 36 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 7/95 Voi. 37 A95 A95 A95 A95 A95 A95 A95 A95 Vol. 38 Vol. 39 Vol. 40 Vol. 41 RS-002814 1/17/02 NUECES INTERPRETATIONS NO. 37 -- SECTION IV Replies to Technical Inquiries January 1, 1995, through June 30, 1995 FOREWORD General Information This publication includes all written interpretations issued between the indicated dates by the ASME Staff on behalf of the ASME Boiler and Pressure Vessel Committee in response to inquiries concerning interpretations of the ASME Boiler and Pressure Vessel Code. A contents is also included which lists subjects specific to the interpretations covered in the individual volume. These interpretations are not a part of the Addenda or the Code. The interpretations are taken verbatim from the original letters, except for a few typographical and editorial corrections made for the purpose of improved clarity. In some instances, a review of the interpretation revealed a need for corrections of a technical nature. In these cases, a revised interpretation is presented bearing the original Interpretation Number with the suffix R and the original rile number with an asterisk. Following these revised interpretations, new interpretations and revisions to them issued during the indicated dates are assigned Interpretation Numbers in chronological order. Interpretations applying to more than one Code Section appear with the interpretations for each affected Section. ASME procedures provide for reconsideration of these interpretations when or if additional information is available which the inquirer believes might affect the interpretation. Further, persons aggrieved by an interpretation may appeal to the cognizant ASME committee or subcommittee. As stated in the Statement of Policy in the Code documents, ASME does not "approve," "certify," "rate," or "endorse" any item, construction, proprietary device, or activity. An interpretation applies either to the Edition and Addenda in effect on the date of issuance of the interpretation or the Edition and Addenda stated in the interpretation. Subsequent revisions to the Code may supersede the interpretation. For detailed instructions on preparation of technical inquiries to the ASME Boiler and Pressure Vessel Committee, refer to Appendix I. 173 R8-00281B 1/17/02 NUECES 1 Subject HG-312.1 and HG-603 ............................. HG-315.2(a)(3)........................................... HG-530.1 ................................................... HG-S30.2 ................................................... HG-6Q5 and HG-613................................. HG-703.2 ................................................... HLW-100(aX4) and HLW-200(d) and (f) Stamping SECTION IV Interpretatiop IV-95-09 IV-95-11 IV-95-10 IV-95-07 IV-95-06 IV-95-13 IV-95-12 rV-95-08 File No. BC95-032 BC95-041 BC95-033 BC94-537 BC94-469 BC95-103 BC94-628 BC94-538 3 RS-002816 1/17/02 NUECES ) 175 Section IV -- Interpretations No. 37 IV-95-06, IV-95-07, IV-95-08 Interpretation: IV-95-06 Subject: Section IV, HG-605 and HG-613 Date Issued: January 23, 1995 File: BC94-469 Question: Does para. HG-605 requiring two pressure controls and para. HG-613 requiring two temperature controls apply to all sizes of boilers? Reply: Yes. Interpretation: IV-95-07 Subject: Section IV, HG 530.2, Marking Requirements for Cast Iron Boilers Date Issued: January 23, 1995 File: BC94-537 Question: Is it permissible to use either the assembler's name or abbreviation of that name, on Cast Iron Sections, when the discretion of when to use the name or abbreviation is described in the Quality Control Manual? Reply: Yes. Interpretation: IV-95-08 Subject: Section IV, Stamping Date Issued: January 23, 1995 File: BC94-538 Question: May the Code Symbol Stamp and other pertinent information other than MAWP be physically stamped on grey cast iron (SA-278, Class 25) components or parts after the casting operation is completed? Reply: No. 88-002817 1/17/02 NUECE8 177 FV-95-09, IV-9S-10, IV-95-11 Section IV -- Interpretations No. 37 Interpretation: IV-95-09 Subject Section IV, paras. HG-312.1 and HG-603 Date Issued: March 13, 1995 File: BC95-032 Question: Does HG-603 prohibit the Manufacturer of a horizontal fuetube boiler from establishing the "lowest permissible water level" below the top of the top row of tubes? Reply: No. Interpretation: IV-95-10 Subject: Section TV, HG-530.1 Date Issued: March 13, 1995 File: BC95-033 Question (1): Would the supply and return of a common header located on the side of a copper finned watertube type boiler be considered the same as "outlet drum" as in HG-530.1(b)(3)? Reply (1): Yes. Question (2): If the answer to question (1) is yes, would locating the original ASME Code symbol stamp and required data on the bottom of this supply and return header facing downward toward the ground be acceptable with HG-530.1 (b)(3)? Reply (2): Yes. Interpretation: IV-95-11 Subject: Section IV, para. HG-315.2(a)(3) Date Issued: March 13, 1995 File: BC95-041 Question: Should the minimum thickness of 0.061 in. specified in para. HG-315.2(a)(3) be measured before rolling? Reply: Yes. 178 RS402B1* 1/17102 NUECES Section IV -- Interpretations No. 37 IV-95-12, IV-95-13 Interpretation: IV-95-12 Subject: Section IV, HLW-100(a)(4) and HLW-200(d) and (f) Date Issued: June 7, 1995 File: BC94-628 Question (1): May a water heater or storage tank be stamped HLW if the entire interior of the vessel is lined with a minimum of 0.005 in. copper applied by the thermal spray method? Reply (1): Yes, as permitted by Code Case 2163. Question (2): May a water heater or storage tank be stamped HLW if the thermally sprayed copper lining is then lined with a minimum of 0.003 in. of polyamine epoxy to HLW-200(f)? Reply (2): Yes. Question (3): If the answer to Question (2) above is yes, is the polyamine epoxy counted as the Code lining which goes on the Manufacturer's Data Report? Reply (3): Yes. Interpretation: IV-95-13 Subject: Section IV, HG-703.2 Date Issued: June 7, 1995 File: BC95-103 Question: Is it required to install a "Hartford Loop" on the return piping of a gravity return steam heating boiler when two low-water cutoffs are installed? Reply: Yes, HG-703.2 requires that the return piping be attached so as to form a loop substantially as shown in Fig. HG-703.1, commonly known as a "Hartford Loop," regardless of the number of lowwater cutoffs to be installed. 179 RS-002819 1/17/02 NUECES 1995 ASME Boiler & Pressure Vessel Code An American National Standard I Power Boilers ISBN 0-7918-2400-4 Order No. PX0010 $180.00 II Materials Part A - Ferrous Material Specifications ISBN 0-7918-2401-2 Order No. PX002A $350.00 Part B - Nonferrous Material Specifications ISBN 0-7918-2402-0 Order No. PX002B $325.00 Part C - Specifications for Welding Rods, Electrodes, and Filler Metals ISBN 0-7918-2403-9 Order No. PX002C $305.00 Part D - Properties ISBN 0-7918-2404-7 Order No. PX002D $255.00 in Rules for Construction of Nuclear Power Plant Components Subsection NCA General Requirements for Division 1 and Division 2 ISBN 0-7918-2405-5 Order No. PX003R $190.00 Division 1 Subsection NB Class 1 Components ISBN 0-7918-2406-3 Order No. PX003B $220.00 Subsection NC Class 2 Components ISBN 0-7918-2407-1 Order No. PX003C $220.00 Subsection ND Class 3 Components ISBN 0-7918-2408-X Order No. PX003D $220.00 Subsection NE Class MC Components ISBN 0-7918-2409-8 Order No. PX003E $220.00 Subsection NF Supports ISBN 0-7918-2410-1 Order No. PX003F $160.00 Subsection NG Core Support Structures ISBN 0-7918-2411-X Order No. PX003G $160.00 Appendices ISBN 0-7918-2412-8 Order No. PX003A $240.00 Division 2 Code for Concrete Reactor Vessels and Containments ISBN 0-7918-2413-6 Order No. PX0032 $280.00 IV Heating Boilers ISBN 0-7918-2414-4 Order No. PX0040 $180.00 V Nondestructive Examination ISBN 0-7918-2415-2 Order No. PX0050 $195.00 VI Recommended Rules for the Care and Operation of Heating Boilers ISBN 0-7918-2416-0 Order No. PX0060 $110.00 VH Recommended Guidelines for the Care of Power Boilers ISBN 0-7918-2417-9 Order No. PX0070 $125.00 Vm Pressure Vessels Division 1 ISBN 0-7918-2418-7 Order No. PX0081 $340.00 Division 2 Alternative Rules ISBN 0-7918-2419-5 Order No. PX0082 $340.00 IX Welding and Brazing Qualifications ISBN 0-7918-2420-9 Order No. PX0090 $195.00 X Fiber-Reinforced Plastic Pressure Vessels ISBN 0-7918-2421-7 Order No. PX0100 $155.00 XI Rules for Inservice Inspectic Nuclear Power Plant Componei ISBN 0-7918-2422-5 Order No. PX0011 $335.00 Code Cases: Boilers and Pressure Vessels ISBN 0-7918-2423-3 Order No. PX0120 $250.00 Code Cases: Nuclear Componen ISBN 0-7918-2424-1 Order No. PX012N $295.00 Binder The Code is available in looseleaf forr. A customized binder is available for \ convenience: cloth over heavy board, reinforced hinges, 5-prong mechanism 27j" capacity. Order No. PX0140 $20.00 Special Price for Complete Code Order No. PX0230 $5,250.00 Complete Code Plus 25 Binders Order No. PX0330 $5,750.00 Update Service Includes: Addenda issued once per year. Deo 1995, 1996, 1997 Supplements issued 4 times per yeai Code Case Book Interpretations issued twice per yeai Addenda and in July 1995,1996, 1997 Interpretations will not be available se and are issued as part of the update s> to the individual sections of the Code. Interpretations to Section III, Divisior and 2 are issued as part of update to Subsection NCA. TO ORDER: Call toll free 800-843-2763 Fax 201-882-1717 Write ASME 22 Law Drive Box 2300 Fairfield, NJ 07007-2300 All orders require a vslid purchase order. When ori with your company purchase order, please make ' your ASME account number, if available, is indicate account number can be found on ASME invoices. [ lists, and statements. Prices subject to change without notice. Shipping/h charges added to every order. R8-002820 1/17/02 NUECES Available July 1,1995 1995 Edition ASME Boiler and Pressure Vessel Code RS-002821 1/17/02 NUECES