Document 3eenM6r7r2qZBJYpKOev9rwB3
Air Conditioning, Automatic Heating Systems
Williams Oil-O-Matic Heating Corporation
Manufacturers of Automatic and Manually Controlled Fuel Oil Burners
Bloomington, Illinois
Service to Architects and Builders
.Chicago. III., 641 N. Michigan Avenue
New York, N. Y., 2014 Graybar Building
For Williams Ice-O-Matic Refrigeration Equipment see File Index
A Complete Line
Williams Oil-O-Matic offers six Oil-O-Matic burner models--a genuine Williams Oil-O-Matic for every size and type of house, for every apartment, public building or commercial structure. Also, thenew WilliamsHP-3 (high pressure) model.
Complete boiler burner and furnace-burner units; a new typeofoil-burningautomatic water heater; an oil-
OnSiCburning range burner (or
heavy duty ranges are availal e.
Oil-O-Matic Water Heaters
Made in 3 sizes covering ordinary home use, large home or commercial use, and heavy duty require ment. The Oil-O-Matic oil burner, combustion cham ber, water reservoir, and all automatic controls are com bined in one compact unit. Horizontal tank permits the use of a unique triple flame' travel which transfers all possible heat to the water. See specifications lower left.
Heating Capacities of the Various Williams Oil-O-Matic Burners
Gals. Fuel
iri
ftModel
.c ff c
.S 4a
.s J 1
4 .s
o 0u
Oil per Oper ating Hour
Mini Maxi
mi & x k mum mum
K-150 125
K*i 145
k*</i 170
k-7 175
LJ-1800
255 295 115
(Hixhpressurc) i
29 ISJil I9^||/I0|1800 30 I53< 20^jl/l0jl800
20Vf 22X11/5 jlSOO 32VS ay. 21X0/5 1800 45 20 24* 1/2 1800 50 32 24 jl jl800 30 17 18 1/101800
'/2 1
2X 4 8 12 135
l'/2 3
4/j
7
15 25 .3
Standard draft pipe" 18 in. I2-in. length draft pipe optional.
Standard electric current is 110-volt. 60cycle. In case odd frequency motors are used, the maxi mum capacity of the burner will be reduced in direct proportion to the rpm of the motor. The minimum capacity remains the same.
Water Heaters
WHAT 600 57 22K 28 Il/I0|l800
WHBt 885 75 23 WHCf 1385 90 29
28 (l/10il600 'A 34 i/ropeoo 1
1%
Output: 90 F rise, 60 gal per hour. fOutput:
F n$e. 120 gal per hour. tOutput: 90 F
rise, 210 gal per hour.
r
Complete Boiler-Burner and FurnaceBurner Units
Oil-O-Matic burners are also used as an integral part of the following boiler-burner and furnace-burner units:
Abram-Cox Oil-O-Matic, Evans Oil-O- * Matic, International Oil-O-Matic, Kruse Oil-O-Matic, Orr & SembowerOil-O-Matic, Waterman-Waterbury Oil-O-Matic
Boiler-burner units automatically pro vide domestic hot water supply the year 'round. Indirect heating coils may be included for either instantaneous or storage tank systems. Furnace-burner units pro vide winter air conditioning.
Horizontal Boiler-Burner Unit
A complete Oil-O-Matic product, con sisting of a boiler and Oil-O-Matic oil burner. It is furnished for both steam and hot water systems. The welded steel tank used meets A.S.M.E. code specifications for operating up to 15 lb pressure. Boiler Rapacities are: 610 sq ft equivalent direct steam radiation; 980 sq ft equivalent direct hot water radiation.
How to Decide Size of Burner
For low pressure domestic boilers, 1 gal of fuel oil per hour (140,000 Btu) is re quired for approximately:
300 sq ft of steam radiation or its equiva lent.
480 sq ft of hot water radiation or its equivalent.
70,000 Btu when using hot air furnace ratings.
24 sq ft steam boiler heating surface (or 2.2 np).
For exact detail data, see Oil-O-Matic Installation and Service Manual.
Underwriters' Listing ' Listed as standard by Underwriters' Laboratories, Inc. Also approved by all important codes and governing bodies.
Fuel Oil Range Burners
Williams Oil-O-Matic fuel oil burner for use with heavy duty ranges in restaurants, hotels, hospitals, steamships, dining cars, resorts and clubs. Furnished as an integral part of the Oil-O-Matic South Bend Heavy Duty Range.
Engineering Service
Available'to architects. See A. /. A. File No. 30 G-l.
920
Air Conditioning, Water Treatment
Oakite Products, Inc.
22 Thames Street, New York, N. Y.
Branch Offices and Representatives in
All Principal Cities of the U. S.
OAKITE
AIREFINER
Established 1909
A new material that prevents corrosion, controls bacteria growth, prevents slime and algae ac cumulations. Materials also available for rust and scale removal, cleaning and deodorizing.
Bacteria, Slime and Algae Control
Does your air conditioning equipment use a recirculating water supply? Increase the efficiency of it by preventing the growth of bacteria, slime and algae in the circulating water. This is accomplished easily, inexpensively with a new develop ment of the Oakite Research Laboratories, known as Oakite Airefiner. It is a dry, non-volatile white powder, completely soluble in water to provide safe, odorless, non-toxic solutions. Used in extremely low concentrations, one pound to 300 to 500 gal of water, this powerful bacteri cidal agent controls the growth of bacteria, slime and algae. Equipment is kept free of these accumulations, and from the un pleasant odors which they create.
Preventing Corrosion
Oakite Airefiner has been specially com pounded to also incorporate sufficient alkalinity to counteract the development of acidity in the water due to extraction of sulphur dioxide and carbon dioxide gases from the air. If not prevented, this acid condition causes rapid corrosion of elim inators, air wash chambers and other metallic surfaces with which the untreated water comes in contact.
Cleaning and Deodorizing
Users of Oakite Airefiner enjoy a number of other definite advantages. Increased wetting power of water con taining Oakite Airefiner has resulted in actual removal of more dirt from the washed air. Eliminators, spray heads and water feed lines are kept free of scale and similar corrosion as well as of bacterial accumulations, slime and algae. The washed air is freed of practically all the matter which is responsible for objection able odors in re-used air.
Cleaning Filter Screens
Where filters are of the re-usable and washable type, Oakite cleaning methods provide a quick, safe, complete removal of the accumulated dust and dirt. No injury is done to the glass, metallic or similar material which comprises the filtering surface.
Rust and Scale Removal
Removal of rust and scale from feed water pipes, water cooling chambers or on other metallic surfaces can be accomp lished safely and economically with Oakite Compound No. 32. -This is an acidic material especially prepared to provide absolutely uniform scale and rust dis solving action without having any harmful effect on the sound underlying metal. Specific recommendations on work of this type will be sent upon request.
Nation-Wide Service
Oakite materials are supplied through a nation-wide group of service representa tives who are thoroughly experienced in their application. Users are thus assured of employing the materials in the way to get the full bene fits they provide.
Write for FREE, interesting fact-filled booklet on the use of Oakite Airefiner and the other Oakite materials designed specifically for help ing you get the max imum life and perfor mance from your air conditioning equip ment. No obliga tion, of course.
921