Document 3eVy5Zoja4VezxrO7YpzQj340

r MOTOR and WIRE RATING DATA 269 3 s MAGNET COIL SUFFIX NUMBERS - Apply to Catalog Numbers 9560 9575, 9584, 9586, 9589, 9594, 9656, 9658, 9736 and 9739 only. Voltage 60 cycles Frequency 50 cycles 25 cycles This section contains: Pages 1 Magnet coil suffix numbers...................................269 Average motor ampere ratings..................... 272-273 J0e^oi=Oi0 Ss| gs- 6 12 24 32 no 115 115/120 115/230 120 208 208/220 220 220/240 230 240 380 440 480 500 550 -26 -27 -28 -29 -1 -14 -46 -20 -39 -45 -2 -42 -23 -15 -40 ... -3 -41 -4 -30 -34 -31 -35 -32 -36 i -33 -37 -5 -10 i -16 ... -18 1 -21 -22 1 -43 --44 ; ... ... -6 -11- . -24 -25 : -17 -19 . -7 -8 -12 -38 ... -9 -13 Motor branch circuit fuse, wire and t,f circuit breaker selection...................................... 271 i Relay operating times............................................ 278 >, Resistors -- service classifications and recommendations.................... | 276-278 ' Transformer selection for control circuits . . .274-275 i! Wire: Current-carrying capacities............................... 270 : Motor branch circuit selection............................. 271 ' Number per conduit or raceway....................... 269 Voltage drop..................................................... 270 i so coo hho OmSJO2 r" go _j o o oo-4 WIRE and CONDUIT TABLES -- Based on igez n.e.c. ` oo o MAXIMUM NUMBER OF CONDUCTORS IN CONDUIT OR TUBING - Types RF-2, RFH-2, R, RH, RW, RH-RW, RHW, RHH, RU, RUH, RUW, SF, SFF, TF, T, TW, THW and THWN (See sections 300-17, 300-18, 346-6 and 348-6 of 1962 N.E.C.) -- Derating factor for more than three conductors in raceways, see Note 8 on next page. Wire Maximum Number of Conductors in Conduit or Tubing Size (Based upon % conductor fill, Table 3, Chap. 9, for new work) or W K 1 114 114 2 214 3 314 4 5 6 MCM Inch Inch Inch - Inch Inch Inch Inch Inch Inch Inch Inch Inch oT1 2 O o3 S3-0n035 3 50 0 18 7 12 20 35 49 80 115 176 16 6 10 17 30 41 68 98 150 14 4 6 10 18 25 41 58 90 121 155 12 3 5 8 15 21 34 50 76 103 132 208 10 1 4 7 13 17 29 41 64 86 110 173 8 1 3 4 7 10 17 25 38 52 . 67 105 152 6 1 1 3 4 6 10 15 23 32 41 64 93 4 1 1 1 03 5 8 12 18 24 31 49 72 3 1 1 3 4 7 10 16 21 28 44 63 2 1 1 3 3 6 9 14 19 24 38 55 1 1 1 1 3 4 7 10 14 18 29 42 0 1 1 2 4 6 9 12 16 25 37 00 1 1 1 3 5 8 11 14 22 32 000 1 1 1 3 4 7 9 12 19 27 0000 1 1 2 3 6 8 10 16 23 250 111 3 5 6 8 13 19 300 1 1 1 3 4 5 7 11 16 350 111 T 3 5 6 10 15 400 11 13 46 9 13 500 11 1 3 4 5 8 11 2>^-o4 o> << TO mv 600 1 1 1 3 4 6 9 700 1 1 1 3 3 6 8 ! 750 1 11 33 58 800 1 1 1 2 3 5 7 900 1000 1250 1500 1750 1 1 11 11 11 1 1 1 1 1 1 1 3 3 1 1 1 4 4 3 3 2 7 6 5 4 4 O<m r~ > O ~n -rHn 0050 2000 1 1 1 1 3 =0-0 m. O O Where an existing service run of conduit or electrical metallic tubing dos not exceed 50 ft. in length and does not contain more than the equivalent of two quarter bends from end to end, two No. 4 insulated and one No. 4 bare conductors may be installed in 1-inch conduit or tubing. >-< GO CUTLERoHAMMER 269 I i .---a