Document 3e8Gm8Ea8wa0BLnd0Zp2r5DRn

132 CHAPTER 7 1952 Guide during the recent smog. Older individuals were more seriously affected with cardio-respiratory symptoms. Study of such a situation is rather difficult, as explained in the afore mentioned report. The medical profession has much to learn about the effects of these substances on human beings, and until more precise knowl edge is obtained, it is difficult to know when precise controls are really needed. Further research is urgently needed.* SANITARY VENTILATION During the last 15 years great popular interest has been aroused in the spread of respiratory infection indoors and control by ventilation or its sanitary equivalent by air disinfection. Three important documents have appeared in English, Swedish and French literature recently.4' *6 In this country, where the study initiated, the Council of Physical Medicine of the American Medical Association approved the radiant dis infection of air in 1943, and two sub-committees of the Committee on Research and Standards of the American Public Health Association have reported favorably upon the control of airborne infection by sanitary ventilation and on air sanitation, respectively.7-8-9'10 The work of a Technical Advisory Committee on Air Sterilization of the ASHVE has from time to time reported progress in the Journal since 1944, and has approved a set of definitions, formulations and factors which is now being reviewed by the Committee of Research and Standards of the A.P.H.A. with the purpose of joint adoption by the Association and the Society. Since this important new field of sanitary ventilation is yet in its infancy, just emerging from the research and development stage, it has not been possible to prepare a comprehensive treatment in The Guide. Those pro fessionally interested must still refer to the official publications of the or ganizations listed, and the enormous technical literature on the subject which they review. The following section on Control of Airborne Infec tion gives some idea of the scope of the subject. CONTROL OF AIRBORNE INFECTION The majority of airborne diseases are spread indoors where people gather. Any program of air sanitation is influenced by a number of factors. In the winter months, the closing of doors, windows and other means of access to the outside air to conserve warmth, as well as the crowding of persons indoors, provides conditions conducive to a high incidence of contagion. This seasonal phenomenon, illustrated in Fig. 1 which represents a study made by the U. S. Public Health Service, will concern the ventilating engineer insofar as air quality (determined by temperature, humidity, air replenishment and type of air movement and by freedom from contamina tion) is a major intrinsic factor. Apart from the seasonal picture of air borne contagion, are such extrinsic factors as rate of turnover of personnel, and the marked susceptibility of the recruit in comparison with permanent personnel11 as shown in Fig. 2 by studies of military personnel housed in barracks. These extraneous variables and the factor of contact infection (direct spray) tend to complicate any evaluation of the effectiveness of air sanitation for elimination of micro-organisms in droplet-nuclei and drop let-dust. Thus, control measures may eliminate consistently 90 percent of airborne organisms in laboratory tests, but cannot effect a decrease in actual incidence of infection exceeding 30 percent. Thirty percent may Air Conditioning in Prevention and Treatment of Disease 133 be the maximal reduction in infection possible by air treatment methods. The distinction should be clearly drawn, therefore, between the effective ness of a procedure in laboratory tests and its effectiveness and applicability in actually reducing the incidence of airborne disease. On the other hand, recent studies suggest that inhalation of dust-borne bacteria is more im portant than direct inhalation of infectious droplets or droplet nuclei'in. the spread of respiratory tract infections.11 The following sequence of events has been postulated as occurring' in a large proportion of intra-ward infections: (o) ejection of relatively large protected infective particles from patients; (b) rapid venting or settling of these particles so that those remaining airborne are in low con- Fig. 1. Study ofAverage Monthly Frequency (1921-1926 inclusive) of Speci fied Respiratory Diseases* centration; (c) survival of infective particles to permit the accumulation of high concentrations on surfaces; (d) repeated, reintroduction of infective particles into the air under the stimulus of ward activities or by air currents of the order of 50 fpm over the floor; and (e) extension of infective areas by air turbulence throughout the ward or hospital. The most important link in this probable infection chain has been demonstrated to be the reintro duction of particles into the air.13 Intensive studies on air disinfection have indicated two distinct control measures: (o) suppression of dust and lint, and (b) disinfection of dropletnuclei. A third measure, control of relative humidity is important. It aas been shown that the viability of certain organisms sprayed into the atmosphere from a liquid suspension is dependent on relative humidity, fhe mortality rate of the organisms is very high at a relative humidity of 50 percent,14 and decreases at humidities above and below this figure. It