Document 3YRyZDXg4NbMGmvz2O0xXdqJ

4*' j'CL ,v , c'. Cor.ant-ftt.ar.ta H. . LoveJoy -Atlanta r. o..'.x ,,i.-0 _ December 16, 1959 Hr. j. v, weber President Dixit Dieoastlng Company Raideville, North Carolina Dtar Hr, Weber1 Z havt been asked to forward. information relative to the toxicity of fydraul f-9 and/ fydraul A-20CU Thtrt la enclosed data entitled, "The Dieeueeion and Interpretation of fydraul 7-9 Toxicity studies" which supplement* the su--itry which appeare on page 10 of the enclosed fydraul F-9 technical bulletin. In the oaae of fydraul A -800, our interpretation of the toxicity data obtained on thie newer synthetic hydraulic fluid ie that accidental ingestion is not a particular haxard in view of the high oral lethal doee (Oral LD501 10,500 ng/kg), Ilnilarly, single massive skin exposures should not be lewsdlatcly hasardoue (Skin KLPi 623 to 1,230 ag/kg), The lethal doee following skin penetration le such, however, that prolonged and repeated ekin contact should be evolded. Such exposure must alao be avoided to prevent skin irritation. * also feel that vapor inhala tion should be avoided when the fluid Is at elevated tempera tures. gush exposure again relates to prolonged or repeated expoeures rather than massive or acute expoeure. In the ease of the latter, workmen would probably not voluntarily subJcot themselves to concentrations that are hasardoue for short periods. In general, 1 would say that the low degree of hasard Is oharasteristic of both of these materials. If X can be of any further help, please let me know. Very truly yours. EVtdh closures g Klaer f. Wheeler Assistant Direotor Medical Department DSN 018758 STLCOPCB4005302