Document 3XY4VM5bY8KGpj88nYxYvGKO
PLAINTIFF'S
exhibit
CHR-n9
TO * *t
S. C. Enders
fOM SAME
`
L. Redmond
w
NTER COMPANY COI
fi LC
cooc
DEPT "Manager-,-Friction- Division
October 16 , 19(
plant o^T'CC
Materials Development Chemical
Trenton Chemical
OCT
DIVISION
Industrial Hygiene
Personnel
PLANT O^fiCC
Highland Park
Noise Levels, Airborne Asbestos Dust and Exhaust Ventilation Deoartment 4400
As requested by Mr. E. R. Lombard, a noise survey was performed at specific locations in the subject plant by the writer on September 24, 1969. Also, for the purpose of establishing data in the disc brake opera
tions, air samples were collected to determine quantities of airborne asbestos dust and exhaust ventilation systems
were tested on September 24 and October 8, 1969. The results obtained are listed on the attached data sheets.
Discus sion
As indicated on the data sheet, the major noise source in the areas surveyed is the compressor. Readings of 90 to 91 decibels on the "A" scale (dBA) of a standard sound level meter were obtained on the first floor during the compressor air discharge. The noise level was 103 to 104 dBA at a distance of three feet from the compressor, which is located on the second floor. During the normal compressor operation, the readings obtained at the same
two locations were 84 to 86 dBA and 93 to 94 dBA.
The hearing risk criteria adopted on May 20, 1969, under
the authority of the Walsh-Healey Public Contracts Act, permits exposure to a noise level of 93 to 94 dBA for five hours per day. Since only maintenance operations are performed in the immediate vicinity of the compressor, where continuous noise exposures fall into this category, the actual exposure will be for short periods of time. Assuming a work station at a distance of three feet from the compressor,the maximum exposure time to the air dis charge noise would be approximately one half hour per day. Exposure to a noise level of 103 to 104 dBA is permitted for a duration of lfc hours daily. Based on calculation
U0-77* new. 1-J
2- -
as contained in the Waish-Healey Act, the total pertr.issible exposure time at a distance of three feet from the compressor is 4^ hours. This length of exposure appears to be unlikely.
Asbestos dust concentrations were found to be at satis factory levels. The samples obtained at the Besly Grinder contained an average of 4.0 million particles per cubic foot of air (mppcf) which is below the estab lished threshold limit value of 5.0 mppcf.
The readings obtained with an Alnor Velometer indicate
good exhaust ventilation control of operations surveyed.
hm Attachments
cc: W. F. Bavinger R. F. Bowers M. F. Bruton, M.D W. T. Diehl D. L. Eschelbach W. L. Knapp, M.D. T. J. Lang E. R. Lombard F. E. Repucci N. A. Trombley
,/ A &C<-
Louis Redmond Industrial Hygienist
Data Sheet Trenton Chemical Plant Friction Materials Operation
Noise Levels
Location
Sound Pressure Level in Decibels
re: 0.0002 Microbars
"A" Scale. Slow Respons<
U. S. Department of Labor - Permissible Noise Exposure Level:
for 8 hours per day for 6 hours per day for 4 hours per day for 3 hours per day for 2 hours per day for 1^ hours per day for 1 hour per day
90 92
95 97 100
102 105
Department 4600
First floor, loading Littleford mixer area, compressor noise
Same location, compressor discharge every 1^ minutes Second floor, within three feet of compressor Same location, compressor discharge every 1^ minutes Second floor, Mr. J. Nordman's office Same location, compressor discharge Second floor, southeast office Same location, compressor discharge
84-86
90-91 93-94 103-104 72-75 81-82 71-73 80-81
The above readings were obtained with a General Radio Company Sound Level Meter, Type 1565a.
Data Sheet Trenton Chemical Plant Friction Materials Operation
Asbestos Dust Concentrations
Location
Results in Millions of Particles per
Cubic Foot of Air
Threshold limit value
Department 4400: September 24, 1969;
Bay E-7, at Comins Saw #103066 Bay F-4, at east Bipel Machine,
loading material
Repeat of above Bay F-4, at west Bipel Machine,
loading material
Bay F-7, loading BeslyGrinder
weighing weighing
and and
5.0
less than 1 2.0
less than 1 less than 1
6.0
October 8, 1969; Bay F-4, at west Bipel Machine, weighing and
loading material Repeat of above Bay F-7, loading BeslyGrinder Repeat of above Bay F-7, inspection operation east of Besly Grinder
1.2
1.2 4.1 2.1 2.0
The above samples were obtained with Mine Safety Appliances Company Midget Impingers and a Monetaire Pump.
Data Sheet Trenton Chemical Plant Friction Materials Operation
Exhaust Ventilation
Location
September 24, 1969; Bay E-7, Comins Saw #103066, circular saw with good enclosure Bay F-7, Besly Grinder, good enclosure Bay F-4, west Bipel Machine Bay F-4, east Bipel Machine
October 8, 1969;
Inspection table west of Besly Grinder, four
openings, down draft exhaust
Results in Feet oer Minute
200 600-800
175 175
400-500
The above readings were obtained with an ALnor Velometer, Type 3002.