Document 3Qbp3o0O40V9qBXVdJO7krVry
39064,
InI&jdyto_ Stfhi^ct____
B Memo 8/29/75
MEMORANDUM
Date ^/15/75 From
BBH
ftegIZONTAL CRACKING
Tn B- Mr. Heim
INTRODUCTION & SUMMARY
\
At the present time, althpugh therms is more understanding of the nature
and scope of the cracking problem than there was a year ago, there is no
reconmendation for a positive cure for the problem. We know that this
type of cracking does not occur on a shingle that is not sealed down.
The experience encountered in trying to eliminate the self-sealing feature
from the Architect 70 proves that the most obvious remedy cannot be used.
The public has been convinced that the self-sealing feature makes a
superior product.
Attempts to find means of reducing the susceptibility to cracking while maintaining the seal-down feature have not yet been productive, primarily because of the inability so far to produce horizontal cracking on the machines designed for this purpose. Despite experimenting with varying cycles, there is apparently some condition or combination of conditions encountered in actual service which has not been incorporated into the test cycle. Work is being continued to overcane these shortcomings.
Outdoor exposures on house roofs in Florida have been made starting in 1973 and continuing through early 1975. These include standard Mark 25 shingles and several variations incorporating features which may help improve resistance to cracking. Initial cracking in the control shingles may occur within the next several months, and an Inspection is planned to check this out. Duplicates of these shingles are on Shreveport test decks, but experience has shown that cracking has not occurred in the past as quickly on the Shreveport decks as on actual houses. Therefore,
)
BIRD 011207
39Q&A
MEMORANDUM
In Reply to_
Subject____ D
DateFromTo
--2_________________________________________________________________________
-_______________________________________________________________________________________
early Information is not expected from these test.deck exposures.
CURRENT EXTENT OF CRACKING PROBLEM Attached to this report is a summary obtained from BBQ of the extent of cracking complaints experienced since 1972. It is important to note that this problem is not confined to no cut-out shingles. It Is confined to self-sealing shingles, but Wind Seal shingles are as susceptible as Jets. Mark 25 shingles are the most numerous and costly source of complaints. This is especially dramatic when the difference Is considered between the number of squares sold of Mark 25 shingles and those of Wind Seals and Jets. In 1974 and to date In 1975, the number of cracking complaints on the Mark 25 shingles constitute 49? of those settled. Because of the longer guarantee and higher price the liability Is proportionately much greater.
A study of the complaint summary leads to several additional conclusions: 1. The frequency at Charleston is continuing to Increase, but the dollar
value of all settlements in 1975 seems to be leveling off. 2. The frequency and dollar value of 1975 settlements at Shreveport is
lower than 1974. However, Carl Futrell's replacements in Houston have almost no complaints settled in 1975, versus FutrelVs record of 28? of all Shreveport complaints settled In 1974. Having seen roofs in Houston, BBQ and BBH are convinced that the problem has not ''eased. The 1975 figure appears to be unrealistically low.
BIRD 011208
3904A .
MEMORANDUM
In Reply to.
Subject- 3 -
)
3.
Date
Prom
To
In the Charleston division, Jim Saunders accounted for 40% of the
1974 cracking complaints and 25% of the 1975 complaints. The rest
were divided among the other salesmen, with no salesman having as
many as 10 complaints. 4. In the Shreveport division, Carl Futrell and "Red" Houston accounted
for 53% of the 1974 cracking complaints. "Red" Houston is account
ing for 28% of the complaints in 1975, but the Houston, Texas territory is producing almost no complaints, as explained above in Item #2.
5. Despite the fact that Orlando, Florida, Houston, Texas, and Baton Rouge, Louisiana are high .olume sales areas for asphalt roofing,
and in each case the climate unusually severe. It is fairly evident
that the Influence of the particular salesman In each territory is affecting the rate of complaint settlement. Statistically, It would J appear that cracking is a relatively minor problem In other locali
ties. Actual roof inspections and discussions with other salesmen and managers show that the horizontal cracking can and does happen
anywhere in the country, despite the fact that only in the South is
it of sufficient severity to give rise to a major volume of complaints.
PROGRAM FOR SOLUTION TO PROBLEM Following the first awareness of cracking, in 1969, an Investigation was started to determine the cause and extent of the problem. Personal Inspections were conducted by Carroll Homan and Leonard Weaver from late 1971 through May, 1974. A consultant, Donald J. Smith, was employed to cover the entire eastern part of the United States from Florida and the Gulf States to Hew England.
\
BIRD 011209
390SA
MEMORANDUM
In Reply toDate_________ ___PromTo j Subject__________________________________________ ~ 4 -__________________________________ __
The following conclusions v/ere reached: 1. Horizontal cracking is limited to seal-down shingles. 2. The severity Is greatest where climatic conditions of heat and
humidity are the most severe, i.e., the deep South. 3. The severity in a given location is greatest where the exposure to
the sun Is the most intense, e.g., dark color on the south side of the building, with a low slope roof. 4. with cracking occurring in as little as 3-4 years after installation,
5. Thisphqrwmenbhfsnotlli^lusdtoBrrdshingTes.aTthougblnany'
moi^lsevfetti': tMifc ; ageandwetghlf
6. Despite the lack of complaints in the Perth Amboy and Norwood divisions, cracking is not limited to the South. It has been observed in New England and the mid-Atlantic States, and complaints have been received from the old Chicago division (upper nrld-West). However, the rate of cracking is apparently slow enough in the north to keep complaints to a minimum.
POSSIBLE CAUSES FOR CRACKING Many theories have been advanced to try to explain the cracking phenomenon. Since It is limited to self-sealing shingles, it is apparent that there must be forces causing the shingle tab to contract as it weathers. The tab Is physically held by both nails and adhesive along two parallel lines about 4-5 Inches apart. When the contraction occurs, the forces are
BIRD 011210
3906A
MEMORANDUM
In Reply toDateFrom__________________ To______________________
Nj Subject- 5 -
___________________________________________
concentrated midway between the lines where the tab is heTd, until rupturing occurs.
Obviously variations between shingles cause these contraction forces to vary. The two elements In all shingles which are inclined to contract are, 1) the asphalt and 2) the felt. Since all seal-down shingles do not crack at the same rate, the task in minimizing cracking becomes a matter of Identifying and controlling the critical variables.
POSSIBLE MEANS OF REDUCING CRACKING Asphalt The amount and type of asphalt are believed to play a part in cracking. Since heavy weight shingles have more coating asphalt, and since they do crack faster and more severely, it would appear that there Is more than the optimum amount of coating present. It is known that, on aluminum panels, there is an ideal thickness of asphalt which gives the best crack resistance. Above and below this thickness, cracking occurs more rapidly. In thickness much above optimum, cracking is severe and deep. In the case of shingles, as opposed to aluminum panels, there are one or two layers of granules present. These Interrupt the uniformity of film thickness of the asphalt and, to some extent, diminish the logic' of the thin versus thick film analogy. However, experience does show that thick shingles deteriorate faster than more conventional ones. Therefore, cracking can be delayed by not making the shingles too thick.
Another variable in the case of asphalt is its own resistance to weathering depending on source, processing, etc. In the case of coating on aluminum
BIRD 011211
3906A
MEMORANDUM
In Reply toDateFromTo Subject- 6 -
panels, various asphalts show different rates of failure, with ratios as great as 5:1 in same Instances. Failure Is characterized by cracking which results from shrinkage of the asphalt. Here again, in the case of shingles, the presence of granules affects the failure rate. However, it could be that coating which shrinks and cracks most rapidly on alioninum panels would do the same on a shingle. Therefore, there is some reason to believe that cracking can be delayed through the use of the most durable coating available.
Felt Cellulose felt is known to be an unstable product. When saturated and made into shingles, it exhibits many types of distortion on weathering. Depending on conditions, the shingle will curl, claw, flshmouth, shrink, and, in the case of many self-sealing shingles, crack horizontally.
Experience shows that many of these factors can be controlled. Proper saturation controls curling. Adequate back coating helps control fishmouthing and clawing, although it has also been verified that other subtle variables affect clawing,:such as the pH of the dry felt.
The mechanism of felt shrinkage is successive cycles of wetting and drying. Felt made on cylinder machines, being more directional than that made on a Fourdrinier machine, is more Inclined to shrink in the cross direction. It is also weaker In this direction. It is a reasonable assumption that stabilizing and strengthening the felt could lead to a shingle more resistant to horizontal cracking. It is also believed that
r
BIRD 011212
390<SA
MEMORANDUM
In Reply toDateFromTo
J Subject 7__________ __________________________________________________________________________ -
-_______________________________________________________________________________
maximum saturation and ample back coating should minimize the adverse effects of successive cycles of wetting and drying.
RESULTS OF EXPERIMENTAL WORK TO DATE
Natural Weathering
So far, experimental work has consisted of exposing shingles from mill
trials on actual roofs in the Orlando, Florida area, and attempting to
duplicate the cracking phenomenon under accelerated conditions in the
laboratory.
The following shingles are on roofs In Florida:
1. St. David's Episcopal Church Lakeland. Florida
Applied January 26, 1975
48 squares of Sable Black Std. Mark 25 Shingles made at FB and
60 squares of experimental Mark 25 Shingles made at FB. The
experimental shingles contained 103> ground mica in the coating.
(In lab accelerated weathering tests, the mica greatly improves
the durability of coating asphalts.)
2. House of Wm. H. Crapps Sanford, Florida
Applied July 17, 1974
260# Black Johns-Manville Class A glass mat shingle
3. House of Gerald Hooks Orlando, Florida
Applied July 1, 1974
Mark 25 Shingles, Black. (For weathering comparison with J-M
260# glass shingles, above.)
4. House of E. L. Fulford Sanford, Florida
Applied August 15, 1973
Fiberglass based Jet Shingles (White), run at FB
BIRD 011213
3PWA
MEMORANDUM
In Reply toDateFromTo.
Subject_________________:_______________________ - 8 -_____________________
5. House of Kelly Lake Sanford, Florida
Applied June 16, 1973
Mark 25, Sable Black with the following variations-
a. Std., with adhesive spots
b. Std., except with no adhesive spots
c. Std., except Wind Seal Adhesive spots in vertical bars instead
of spots.
d. Std., except saturation kept deliberately low (138-146%)
e. Std., except low back coating (2.1-2.6#/100 sq. ft.)
Duplicate samples of the above-listed roofing have been exposed on the
Shreveport test deck. Several of them were also exposed on the machines -
at BBH intended to produce cracking under laboratory conditions.
So far, there have been no definitive results anywhere. It Is expected that some cracking may appear on the more susceptible of the older installations by next spring, and an Inspection Is being planned.
Artificial Testing The results of experiments on the BBH artificial testers have been disappointing.
Following the development of some horizontal cracking on a prototype piece of equipment, six new machines were designed and built, with the intention of duplicating and improving upon the prototype. The improvements were In the direction of automatic controls to permit 24-hour operation. The machines were started up about a year ago.
BIRD 011214
3906A
MEMORANDUM
In Reply to.
DateFromTo
Subject___ ___________________________________ - 9 -______________________________________________
The first tests were complicated by the need for correcting unexpected mechanical and electrical equipment problems. Also, in an effort to accelerate the test conditions, initial settings were too severe and produced blistering and/or sealing of the entire tab by back coating Instead of merely at the position of the adhesive dots. Hence, the samples were spoiled as candidates for horizontal cracking.
A new series of sample boards was started In early 19751 The cycles were controlled better to prevent blistering, and sheets of foil were placed between shingles in order to keep them from sticking where they weren't supposed to.
By June, some cracking had begun. It was more or less random, but It was anticipated that horizontal cracking would soon follow. This has not happened yet, nor has the original cracking progressed much. Therefore, It seems necessary to start up a new series of sample boards, after analysis of the reasons of the failure of the series just completed, and their elimination. If possible.
Why Didn't The Accelerated Decks Produce the Desired Results? The intent of the decks was to duplicate conditions which product horizontal cracking in actual service: 1. Degradation of the coating asphalt by UV radiation and heat. 2. Thermal shock by cold water to the shingle ( as produced by frequent
thunder showers In Florida), calculated to Induce cracking In the asphalt embrittled by UV and heat. 3. Moisture from the water used for cooling producing humidity conditions prevalent in the South.
BIRD 011215
3904A
MEMORANDUM
In Reply to__________________ DateFromTo Subject~......................................................................... IQ---------------------------------------------------------------------
In analyzing these conditions, it appears that the UV radiation, heat, and thermal shock were produced as desired. However, the horizontal cracking did not develop. It appears that the cycles used may have produced too much moisture. As a result, the shingle felt became wet. Instead of going through cycles of drying and shrinking, as It does In Florida between showers, it was subjected to another chilling cycle, during which time its moisture was replenished.
These moisture cycles varied from intervals of 2 hours to 15 hours. Even the 15-hour gap between wetting cycles did not permit the felt to ~ dry. (Laboratory fishmouth tests have conclusively shown that a minimum of a week of uninterrupted heating for 24 hours per day Is required to dry the felt enough to produce flshmouthlng.)
In previous attempts to analyze the factors at work in horizontal cracking, this particular one has never been defined with enough precision to cause alterations of the cycles of the test equipment. However, the present set of decks, during the month of September. Is being subjected to alternate weeks with light and heat only but no water. It mey be that It is too late on these particular shingles to produce horizontal cracking. If nothing happens by the end of September, It is planned to discontinue these shingles and begin again with new decks.
SUGGESTED CONTINUED PROGRAM It is proposed to: 1. Continue to follow the outdoor decks-In Florida, with additional
exposures of other products where appropriate.
BIRD 011216
3906A
MEMORANDUM
In Reply toDateFromT_ Subject________________________________________- 11 -___________________________________
2. Make periodic inspections of Shreveport test decks. 3. Continue work on accelerated decks at BBH with cycle variations,
such as more thorough drying to permit felt shrinkage. 4. Make lab studies on shrinkage properties of felt (dry, saturated,
saturated and coated, etc.), apart from the artificial decks to measure amount of shrinkage from alternate cycles of wetting and drying, to see if means can be determined to minimize the dimensional changes and strengthen the felt to reduce its susceptibility to cracking. 5. Continue to check the possible advantages of glass mat shingles with respect to resistance to cracking.
CONCLUSION Since the Mark 25 Shingle is the principal cause for complaints in the South, it would seem logical to drop the product, at least there. However, it seems that this cannot be done completely, since buildings are being specified to use this product exclusively.
Based on the preceding rationale, but lacking proof, there is a chance that the crack resistance of the Mark 25 will be Improved by two steps. One is to make it of uniform thickness, and the other to make it on heavier felt. The first step is to reduce the weight.of the exposed butt without reducing the overall product weight. The second step is to reduce the thickness of coating asphalt and to give a little stronger felt for better resistance to pulling apart.
BIRD 011217
3906A
MEMORANDUM
In Reply toDateFromTo ) Subject________________ ._______________________ - 12 -__________________ __________________
These steps mey not work, but there Is a statistical probability that they should give a few extra years of crack-free performance on the Hark 25.
J
LWWeaver/rp Attach.
F
BIRD 011218
HORIZONTAL CRACKING COMPLAINTS
1972 1973 19741975 (1st. 7 mos.)
Southeastern Div. Charleston FK_________
No. Cost
27 $12,749.23
45 26,131.95
98 65,986.57
74 37,999.21
Southwestern Div. Shreveport FS
No. Cost
12 $ 2,313.98
20 4,379.25
90 32,752.92
47 21,177.22
BIRD 011219
Salesman
C. C. Futrell L. G. Houston C. C. Pregge E. P. Hennessey R. A. Sheffield W. J. Swain W. C. Ingram B. J. Langley A. R. Sawyer J. E. Evans D. J. Schanz 0. W. Cope G. G. Tims H. J. Drasutis J. R. Nugent D. J. Lankford J. H. Studdard D. C. Fischer
W. W. Mason 0. E. Saunders <3. Nelson D. Regan R. A. Scott A. D. GalTaher E. F. Smith J. A. Scull J. Bum C. Ford P. Steele D. S. Clarke J. R. Bellmyer C. D. Harding W. J. Mullins V. Nelson J. M. Dunn
FS - 1974
HORIZONTAL CRACKING COMPLAINTS
No. of Complaints
26 23
3 2 8 6 3 1 3 2 2 3 1 2 ] 1 2 .1
FK - 1974 .
i- - <
>'r `' ' r*'*
- ' 38 '
V, .
, , -. ,35 . .
.
5
3. 4 ..
,7 3 :
: 2- : .2
2 1
;
3
2 9 1
'
s`
, 1 . . ..rk'/zU
-'
BIRD 011220
Salesman
B. L. Pevey F. C. Dietrich J. E. Evans L. G. Houston J. W. Morriss C. C. Pregge D. J. Schanz G. G. Tims J. S. Moll H. W. Williamson C. C. Futrell R. A. Sheffield H. J. Drasutis A. R. Sawyer H. B. Bauchamp J. W. Cope E. P. Hennessey
C. D. Harding W. W. Mason O. E. Saunders J. H. Burn R. A. Scott J. A. Scull C. L. Ford D. S. Clarke P. Steele J. Nelson J. Dunn A. Gallaher W. Mullins
FS - 1975 (1st 7 mos.)
HORIZONTAL CRACKING COMPLAINTS
No. of Complaints
1 1 4 17 2 1 4 2 2 1 1 3 1 1 2 2 2
FK - 1975 (1st 7 mos.)
5 3 28 5
2
4 6 5 1 8 1 2 1
BIRD 011221
Type of Shinqle Hark 25 Wind Seal Jet Wind Seal Seal King Firescreen Master-Bilt
No. of Complaints 1974__________
FK FS 51 38 16 22 19 26
23 31 5'
1975 - (1st 7 mos.) FK FS 33 26 11 11 18 7 12 61 3
BIRD 011222