Document 3Qbdvrq5V1xO9v5LYR1d3eD1D

SPILL NOCTRCATION ANP CONTROL PLAN i Wt I'OLYUIUKINATUI) I'.IPHIi.NYLS (PCK'sJ A. Introduction: . Studies have shown that products containing polychlorinated binhenyls may be persistent, an environmental contaminant and, possibly, injurious to certain forms of bird, aquatic and animal life. Tt is, therefore, extremely imnortant that entrv into the environment ho minimi red in the event of spillage of these materials while they are in transit hy rail tank car or tan! truck. B. Purpose: To establish a simple, effective procedure to be followed hy the manufacturer (Monsanto) and capacitor manufacturers using nnlvchlorinated biphenyls of notification and action, to be taken in case of an accidental spill while the material is in transit from Monsanto to the capacitor manufacturer. C. Spill Notification Procedure: 1. Cach tank car transporting PCB's from Monsanto should ho marked on its sides and ends boldly in 4" to 6" high letters with instructions, In Case cf Snill Call M8/27I-SS3K, collect. 2. Hach capacitor manufacturer should provide Monsanto with a telephone numhei that is manned 24 hours per day 7 davs per week. If this is not possible, then each capacitor manufacturer should provide the names and telophone number of at least three individuals that Monsanto could call in succession, if necessary, in order to make contact to report a snill. 3. Tn the event of a snill call being received hy Monsanto, the person MONS 029614 Exhibit H-l Spill Notification Plan for Polychlorinated niphcnvls .TCP's) Page 2 taking the telephone call informing of a spill should he trained to obtain the following information: a.) The name of thq caller. I>.) The official title and function of the caller. c.) All the information available concerning tho accident such as: 1 Exact location (in sufficient detail to find the site on mans and on the ground). 2 Time of occurrence (as close as possible). 3 Name of transportation company and their emergency calling number. 4 Amount of material spilled. 5 Condition of the transportation equipment. 6 Who'else has been informed (list name and title). 7 Disposition of casualties, if any (what hospital, clinic or physician). 8 Witnesses (name and address). d.) Mow to contact the caller or other responsible narty at or near the scene. c.) Whether local, state and federal pollution agencies have been inrurmed. If yes, who was contacted and at what number. 4. In addition to the above, the following information should be provided to the person reporting the spill by Monsanto, acting as agent for the capacitor manufacturer: ` a.) Material is fire resistant* : b.) It is recommended that rubber boots and gloves of Neoprene or PVC be worn when handling these materials to avoid possible skin irrita tion. 5. Monsanto should immediately notify the appropriate capacitor manufacturer HONS 029615 Exhibit. H-2 Spill Notification Plan for Polychlorinated l!iphcn'fls fPf'll's) Page 3 that a snill of his mater al has taken place ami should provide the in formation obtained per paragraph 3 sections a through c. 6. The capacitor manufacturer, on notification of a spill, should immediately notify state and federal pollution agencies and then dispatch ,a responsible individual to the snill site. a.) To notify the federal pollution agency call b.) To notify state pollution agency, if number is not known call regional I1PA of'ice to obtain state number. (See attached map -- and nhone list.j D. Monsanto's representative will provide the following recommended control procedures'^* *L a.] Do not allow material to flow into sanitary or storm sewers, pond, lakes or rivers. b.) Do not wash material away or into sanitary or storm sewers, ponds, lakes or rivers c.l l.imit the amount that o: capes from the container liv righting the container (tank car or drum), closing valves, plunging a hole with ' a wooden peg or other actions as required. d.l Limit spread of material by using absorbent materials such as dry sand, sawdust, oil absorbers or mgs or by erecting an earthen dam ' using any equipment available in area. e.) Pump any free o 1 standing within the contained area into drums or tank truck. f.) If other freight is contaminated, be sure it is quarantined until disposition can he determined. It must be decontaminated or disposed HONS 02961b Exhibit H-3 Spill Notification Plan for Polychlorinated Biphenyls (PCB'sl of in a responsible manner. Page 4 E. The following clean up-procedures should be considered: a.) If there are shallow wells in the surrounding area, sample the water from the wells and analyze for PCB's. Be sure the water from a con taminated well is not taken internally. b.) Dig up contaminated earth and have it hauled to an area approved for the disposal of PCN*s. c.) Decontaminate any equipment used in the clean up operation or dispose of it in a manner which prevents it entering the environment. 1.) Transportation equipment must he thoroughly cleaned before it can be used fer other purposes. The cleaning of the equipment must not be allowed to contaminate sewers, streams, or other areas not approved for disposal of PCB's. F. Tank Truck Transportation: 1. Companies using their own equipment and personnel to transport their PC8 from the manufacturer or freight yard should have their personnel in structed on how to handle a spill and this should be documented in their own soill control plans. MONS 029617 Exhibit H-4