Document 3Qayon0NjzqzyNJDp9JdnJN6E

UCC 103111 REQUIRED PROJECTS AT S. CHARLESTON PLANT (PC-381) TO MEET EPA AND OSHA VCM REGULATIONS PROJECT I . VC Rectifying Col . Mod Ificat ions 2. VC Vent Col 1ection System 3. Modify VC Feed System 4. VC Vapor Recovery System @ N . C . 5- Portable Vacuum Compressor 6. Replace 4 VCM Transfer Pumps 7- Vent 'Compressor for 2640 Col. Vent 8. Scrubber Vent Line to Powerhouse ENG. ORDER NO. (SHOP ORDER NO.) 938-5708 (79511) 938-5728 (79507) 933-5753 (74388) 938-5374 (20753) 9. Vent Line from VCM Compressor to Scrubber 10. Revise Packing of Autoclave Piston Pumps 11. Determine Need for Back-up VCM Compressor a. Double distance pieces for existing compressor (not installed) ESTIMATED COST, $ 110,000 (1976$) 500,000 300,000 300,000 48,000 (1976$) 24,000 (1976$) 24,000 0 976$) 60,000 1 ,000 0976$) STATUS Process Study in progress Nothing being done Nothing being done Nothing being done Nothing being done Nothing being done Nothing being done Eng. S Constr. in progress Nothing being done REMARKS Estimated to be required in about 3 yrs(?)to meet proposed EPA regulations. Same as itern 1. Same as itern 1. Same as item 1. Same as itern 1. Same as itern 1. Same as item 1. Estimated completion date 3/15/76. Required to meet OSHA regulations effective 4/1/76, and proposed EPA regulations. Same as item 1. In progress Presently evaluating revisions in B-5 and B-6 pumps. B-1 and B-2 need to be done. Required for OSHA and pro posed EPA regulations. 5,000 (1976$) Nothing being done Same as itern 1. (Con 11) PROJECT ENG. ORDER NO. (SHOP ORDER NO.) b. New reciprocating compressor (not installed) c. Hew si iding vane compressor (not in stall ed) 12. 2708 Tank Vent (Wash Acetone) with Compressor 13- Revise Packing of Dilution Tank Pump and Spare. lit. Portable Vacuum Compressor for N.C. 15- Install Line from VCM Sphere to Tank Car for Venting back to car at N.C. .16 Install Valves in VCM Transfer Line from T/C to Sphere to Unit to be Able to isloate Line in 50-gal. segments 17- Install Rupture Disks Under All Safety Valves in VC Service. 18. Replace Dilution Tank Agitator Packing with Double Mechanical Seal 19- Dynatrols for Autoclaves 20. Venti1 at ion System on Bldg. 153 21. Replace Liquid Fi lied Pressure leads wi th transmit ter. ESTIMATED COST, $ 150,000 (1976$) 65,000 (1976$) 18,000 (1976$) 13,500 (1976$) 13,500 (1976$) STATUS Nothing being done Nothing being done Nothing being done Nothing being done Nothing being done Noth i ng being done Nothing being done REMARKS Same as Item 1 . Same as itern 1. Same as itern I. Project hasn't been scoped. Required for OSHA and proposed EPA regulat ions Same as itern 1. Same as item 1. Same as itern 1. UCC 103112 In progress In progress Same as itern 1. Same as itern 1. 2 installed and calibrated 2 being calibra ted 1 on strip, varnish not complete Required for OSHA Essentially complete Required for OSHA Required for OSHA UCC 103113 (CON'T) PROJECT________________ __________ 22. Install Vent Hoods Over Sampling Stations 23 Install Dumpster Loading for R S D 2k. Install Two VC Micro Computer - Gas Chronatograph Monitor Systems ENG. ORDER NO. (SHOP ORDER NO.) ESTIMATED COST, $ STATUS Complete In progress In progress REMARKS Required for OSHA R S D project. Required for OSHA Required for OSHA AJR 2/26/76 /gf