American Society of Heating and Ventilating Engineers Guide, 1934 collector on the negative side of the fan or by lining the housing and blades with rubber. If no future expansion of an exhaust system is contemplated, the fan motor should be chosen to provide the calculated air volume. Should, however, the exhaust system be required to handle more air in the future, the motor should be adequate for the maximum load anticipated. Further information regarding the choice of fans and motors is given in Chapter 17. PROTECTION ACAINST CORROSION The removal of gases and fumes in many chemical plants requires that metals used in the construction of the exhaust system be resistant to Table 6. Loss Through 90-Deg Elbows Elbow Center Like Raltob in Peb Cent or Pipe Diameter 50 100 150 200 to 300 Loss in Peb Cent or Velocitt Head 75 26 17 14 chemical corrosion. A list of the materials which may be used to resist the action of certain fumes is given in Table 7. Hoods and ducts when short, may frequently be constructed of wood and be quite effective. Table 7. Materials to be Used for the Protection of Exhaust Systems Against Corrosion8 Type or Fume Conteted Protective Material to be Used CHlorine. - ................ Rubber lining or chrome-nickle alloys Hydrogen sulphide Ammonia... .. . Aluminum coated iron, aluminum, high chrome-nickle alloys Iron or steel Sulphurous gases.................. High chrome-nickle alloys HvdrorJioIrir. arid Rubber lining, chrome-nickle alloys Nitrous gases..................... Nickle-chrome alloys Condensed from data given by Chilton and Huey (Industrial and Engineering Chemistry, Vol. 24,1932). Rubberized paints are available and may be applied as protective coatings in handling such gases and fumes as chlorine and hydrochloric acid. 290 Chapter 22 CENTRAL FAN HEATING SYSTEMS ,Types of Systems, Blow-Through Draw-Through, Heating Units, Design, Temperatures, Weight of Air to be Circulated, Tempera ture Loss in Ducts, Heat Supplied Heating Units and Washer, Grate Area, Boiler Selection, Weight of Condensate, Static Pres sure, Fans and Control ACENTRAL fan system is an indirect system of heating, ventilating, or air conditioning in which fans and blowers distribute air through ducts from one centrally located plant. This chapter considers heating and humidifying systems of this type; similar systems arranged for cooling and dehumidifying are discussed in Chapter 9. A special type of central fan system, the mechanical warm air or fan furnace system, which is especially adapted to residences and other small buildings is covered in Chapter 23. TYPES OF SYSTEMS In the indirect type of central fan heating and air conditioning system, steam is usually the medium by which heat is transferred from the boiler, or other source of heat, to the heating units. If the system is intended solely for heating, the air is passed over one or more stacks or batteries of heating units and then conveyed to the spaces for which it is intended through a system of ducts. In some cases, a predetermined amount of outside air is introduced for ventilating purposes, whereas in others the moisture content is controlled by passing the air through a washer or humidifier. If the apparatus is designed to control simultaneously the temperature, humidity, air motion, and distribution, it is known as an air conditioning system. In the split system, the heating is accomplished by means of radiators or convectors, and the ventilating or air conditioning by means of the central fan apparatus. In the combined system, the entire operation of heating, ventilating, and air conditioning is handled by the central fan system. A common arrangement of the central fan system of heating is illus trated by Fig. 1 and consists of a fan, heating unit (heater) enclosed by a sheet metal casing connected with the suction side of the fan, a sheet metal casing connected to the heating unit casing run to the outside of the building and provided with an adjustable opening inside the building for recirculation of the air when desired, and a duct system attached to the fan outlet to convey and distribute the air to various parts of the building to be warmed by the apparatus. The fan is ordinarily motor-driven; there are, however, many- cases when a direct-connected steam engine may be used to advantage. In this event the exhaust from the engine can be con- 291