Document 3QX26MQG1m567obbGdNxG2kJO

m 154 CHAPTER 8 1958 Guides ^ particles in the 0.1 micron vicinity may have influenced the determinationin of average particle size. :-u-b0 The lower limit, of particle size visible to the naked eye cannot be stated in definitely. It depends not only upon the individual eye, but also upon the -t-jj shape and color of the particle, intensity and quality of the light, and nature of the background or opportunity for contrast. Under ideal condi- *3 tions a particle of 10-micron size might be recognized, while under less -ft? favorable conditions it may be impossible to distinguish a particle smaller Sj than 50 microns. The lower limit of visibility probably ranges from 10 to ' 50 microns. Dusts, powders and granular materials are frequently classified by refer ence to the size of.screens used for separation. Particles above 40 microns are said to be the screen, sizes and those below, the sub-screen or microscopic sgft sizes.' Approximate or theoretical sizes of particles corresponding to the iff mesh scale of the U. S. Standard Sieve Series are given in Table 1. jjii Microscopic examination of screened dust indicates that the average diameter of a sample of irregular particles may be substantially larger Table 1. Relation of Scbeen Mesh to Pabucle Size U. S.: Standard Sieve Mesh... 400 325 200 140 100 60 35 18 Nominal Sieve Opening in 37 44 74 105 149 250 500 1000 u*. .11 than the openings of the screen through which it has passed, if the particle shapes deviate considerably from the spherical form.2 The smallest di- mension of many such particles will correspond with the maximum per- missible distance between the wires of commercial screens made to ASTMiffi Standard Specifications. Screening does not give sharp separation into|S|| size groups, and accordingly, such a classification is statistical rather than iy, absolute. jj^1 ." fa Contaminants 155: the airborne dust sample. Information'of this type fora specified applica-; tion is best obtained by simultaneous sampling for both counting and weighing and noting carefully at the Time all factors that might affect the reproducibility of the count-weight ratio. Smoke Abatement and Air Pollution Control Successful abatement of atmospheric pollution caused1 by smoke requires the combined efforts of the combustion engineer, industrial executive, public health officer, city planning commission and the community at large. Electrification of industry and railroads, increases in the use of domestic oil and gas furnaces, and segregation of industrial districts are gradually providing effective aid in the solution of this problem. In the large cities where nuisance from smoke, fly,-ash and cinders is more serious, limited areas obtain some relief by the use of district heating. (See Chap ters 14, 15 and 16 for further discussion on;fuel burning technic.) Table 2. Dost Concentration Ranges Location Grains pee 1000 Cu Ft* Rural and suburban districts.............................. Metropolitan district............ .................. Industrial districts................... Ordinary factories or workrooms..................... Excessively dusty factories or mines.............. Minimum explosive concentrations 0.02HK2 0.04-0.4 0.1 -2.0 0.2 -4.0 4-400 4000-200,000 * 1 grain perlOOO cu ft -- 2.3 milligrams per cubic meter. i oz per cubic foot = 1 gram per liter -- 1000 grams per cubic meter Milligrams pee Cubic Meteb 0.05- 0.5 0.1 - 1.0 0.2 - 5.0 0.5 -10 10-1000 10,000-500,000 Many present ordinances limit the number of minutes in any one hour that smoke of a specified density (determined by comparison with a Ringelmann Chart which is described in Chapter 52) may be discharged. There is now considerable interest and activity in the control of air pol lution factors in addition to smoke. Difficulty in the establishment of acceptable criteria for certain corrosive and irritant gases, such as fluorides and the oxides of sulphur and nitrogen discharged with the gases of com- ustion, and the frequently complicated technical and economic problems encountered in control, have delayed the drafting and enforcement of gisiative measures. Recent reports of an increased incidence of diseases, nant ^ Pn<run)nia and lung cancer, in areas high in certain air contamifinaii ' re3ul^e further critical investigation before'aCceptance. The values Alin ^ undoubtedly be lower than the M.A.C. (Maximum : ''[f- Concentration) limits for use in industry, because the exposure 'fnuous compared with the 8-hour day, 5 or 6-day week upon which values are based, and because the exposed population contains In f Ua S Kreater variation in age and health status. mulatirfgyfWeat^er' r an ^nvers^on f atmospheric conditions, accu- respiratorv gaseous contaminants may cause irritation of eyes, nose, and effects TKPaggases' an<* Poss'hly cause even more serious physiological smoo fPpnra i euRe ValleY fg disaster (Belgium 1930) and the Donora air pollutiony T'niL are classic examples in the history of gaseous both instances it is believed that irritant gases, princi-